Starts at
$
175
U M12 Connectors for Fast Connection of
Sensors and Intrumentation
U Use with 2, 3 or 4-Wire Pt100, Pt500
or Pt1000 Sensors
U -40 to 85°C (-40 to 185°F) Ambient
Operating Temperature
U -200 to 850°C (-328 to 1862°F)
Measurement Range
U Small, 38 mm Diameter Housing;
Weighing Just 100 Grams
U 4 to 20 mA or 0 to 10 Vdc Output Models
U IP67 Stainless Steel Enclosure
OMEGA’s TX-M12-RTD Series transmitters offer
improved performance over conventional in-head
transmitters yet are a fraction of their size and weight.
Integral M12 connectors maintain IP67 protection and
connection integrity whilst allowing for a quick and
simple change of sensor. Two models are available
with either 4 to 20 mA or 0 to 10 Vdc output. Default
scaling for the full output is 0 to 100°C (32 to 212°F),
other ranges can be scaled at time of purchase for an
additional charge; or the optional USB programming
module (USB-CONFIG-UNIT) will allow the end user to
perform scaling.
The TX-M12-RTD transmitter is ideal for use with
OMEGA’s PR-21 and PR-22 Series RTD probes, or any
RTD probes with an M12 “A” coded Pin style connector
which connects directly to theTX-M12-RTD sensor
input. Other RTD probes may be easily connected
using the M12-R-M-FM or M12-S-M-FM plug style
field mountable connectors which have screw
terminals connections
C
TX-M12-RTD-C, $175, transmitter shown larger than actual size.
TX-M12-RTD-C, $175.
Dimensions: mm (in) Ø = diameter
C-1
Specifications
Update Time: 200 mS
Response Time: 0.5 seconds
Warm-up Time: 1 minute to
full accuracy
Sensor Connection: 2, 3 or 4-wire M12
Minimum Span: 25°C
Thermal Drift
Pt100: 0.013 Ω/°C
Pt500/Pt1000: 0.063 Ω/°C
Accuracy: ±0.2°C + (0.05%)
+ output accuracy
Excitation Current: <200 uA
Lead Resistance Effect: 0.002°C/Ω
Maximum Lead Resistance:
20 Ω per leg
Operating Ambient: -40 to 85°C;
10 to 90% RH (non condensing)
Configuration Ambient: 10 to 30°C
Weight: Approx 100 g
4 to 20 mA Output Model
Output Type: 2-wire, 4 to 20 mA
current loop
Output Range: 4.0 to 20.0 mA
Output Connection: M12 connector
Output Limits: 3.8 to 21.5 mA
Accuracy: mA output/2000 or 5 uA
(whichever is the greater)
Loop Voltage Effect: 0.2 uA/V
Thermal Drift: 1 uA/°C
Maximum Output Load:
[(Vsupply-10)/20] KΩ
TX-M12-RTD-C, shown with
M12C-SIL-4-S-F-3 cable,
(see omega.com/m12c)
USB-CONFIG-UNIT, allows
re-scaling using a PC
Start Up Time 4 Seconds:
I out < 4 mA during start up
Power Supply: 8 to 30 Vdc
0 to 10 Vdc Output Model
Output Type: 3-wire voltage
Output Range: Selectable within
0 to 10V
Current Drive: 2 mA max
Output Connection: M12 connector
Output Limits: -0.1 to 10.5V
Accuracy: Voltage output/1000 or
5 mV (whichever is the greater)
Thermal Drift: 1 mV/°C
Minimum Output: Load 5000 Ω
Power Supply: 12 to 30 Vdc
PT100, 500, 1000
TX-M12-RTD-C-1 and
TX-M12-RTD-V-1
Sensor Wiring
TX-M12-RTD-C and
TX-M12-RTD-V
Sensor Wiring
PT100,
PT500,
PT1000
MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)
Model Number Price Description
TX-M12-RTD-C $175
TX-M12-RTD-C-1 175
TX-M12-RTD-V 195
TX-M12-RTD-V-1 195
M12C-SIL-4-S-F-3 12
PR-22-3-100-A-1/8-0600-M12
Accessories
Model Number Price Description
USB-CONFIG-UNIT $120
FS20 30
Comes complete with transmitter and operator’s manual (USB-CONFIG-UNIT interface cable sold separately).
Ordering Examples: TX-M12-RTD-C, RTD transmitter set for a Pt100 sensor input, and 4 to 20 mA output over the range of 0 to 100°C
(32 to 212°F), $175.
TX-M12-RTD-V, RTD transmitter set for a Pt100 sensor input, with a 0 to 10 Vdc output over the temperature range of 0 to 100°C (32 to 212°F)
and M12C-SIL-4-S-F-3, M12 extension cable with 4-conductor #24 AWG stranded, silicone insulated and jacketed wire, straight socket style
A-coded M12 connector one end, stripped leads the other, 3 meters long, $195 + 12 = $207.
Software and interface/cable to allow scaling of transmitters with a PC
Factory scaling chargefor ranges other than the 0 to100°C, please specify range required
4 to 20 mA output, connect to PR-21, -2 wiring, PR-22 and P-L-M12 sensors
4 to 20 mA output, connect to PR-21, -1 wiring, PRS-M12 and PR-25AP sensors
0 to 10 Vdc output, connect to PR-21, -2 wiring, PR-22 and P-L-M12 sensors
0 to 10 Vdc output, connect to PR-21, -1 wiring, PRS-M12 and PR-25AP sensors
Extension cable with straight socket M12 connector and 3 meters of silicone
insulation cable
39
Pt100 RTD probe, 1⁄8" diameter x 6" L with overmolded M12 plug connector
C-2