Field Rangeable Miniature
2-Wire Transmitters
Isolated Models Available
Additional
TX900 Series
U Thermocouple, RTD and
Millivolt Input Models
U Compact Size
U 4 to 20 mA Output
U ±0.1% FS Accuracy
TX903 Isolated Model
U
(Other Models Non-Isolated)
U Mounts in Protection Head
TX900 Series transmitters feature
dip switch selection of input
type and range. The following
models are available: TX901
(non-isolated, accepts J, K, T, E,
R or S thermocouples); TX903
(isolated, accepts J, K, T, E,
R or S thermocouples; TX904
(non-isolated, accepts 100 Ω
Pt RTD’s 2- or 3- wire); TX905
(non-isolated, millivolt input).
To scale the units in the field,
calibration equipment is required.
Specifications
Inputs: See input types and ranges
table below right
Output Range: 4 to 20 mA dc
Zero Adjustment: ±25% mV span
centered around 0 mV (or °C)
RTD models ±40°F
Accuracy: ±0.1% FS (includes effects of
linearity, hysteresis and repeatability)
Frequency Response: 3 dB @ 3 Hz
Ambient Temperature Range:
-25 to 85°C (-13 to 185°F)
Storage Temperature Range:
-65 to 125°C (-85 to 257°F)
Supply Voltage: 9 to 35 Vdc;
24 Vdc recommended
Max Loop Vs – 8.5V
Resistance: 0.020
Isolation (TX903 only): 500V RMS
Dimensions:
TX901, TX904: 1.90 H x 4.45 cm D
(1.75 x 0.75")
TX903, TX905, TX906:
2.9 H x 4.45 cm D (1.13 x 1.75")
(height includes barrier strip)
Weight: 30 g (1 oz); 71 g (2.5 oz) for
thermocouple models
power supplies
available,
visit omega.com
for details
Input Types and Ranges
Input Type
TX901/903 0 to 760°C (0 to 1390°F)
TX901/903
TX901/903 0 to 400°C (0 to 750°F)
TX901/903 0 to 835°C (0 to 1515°F)
TX901/903
TX901/903
TX904-1 0 to 260°C (0 to 500°F)
TX904-2
mVTX905 4 to 64 mV
VTX906-V1 0.04 to 0.64V
VTX906-V2 0.4 to 6.4V
VTX906-V2 4 to 64V
†
Note: Factory setting; TX901 Type J 0-500°F, TX903 Type J 0 to 500°F, TX904-1
0 to 300°F, TX904-2 0 to 500°F, TX905 0 to 50 mV.
To Order Visit omega.com/tx900 for Pricing and Details
Model No. Description
TX901 J, K, T, E, R, S thermocouple input, non-isolated
TX903 J, K, T, E, R, S thermocouple input, isolated
TX904-1 100 Ω Pt RTD input (a = 0.00385), non-isolated
TX904-2 100 Ω Pt RTD input (a = 0.00385), non-isolated
TX905 Millivolt input, 4 to 64 mV non-isolated
TX906-V1 Volt input, 0.04 to 0.64V non-isolated
TX906-V2 Volt input, 0.4 to 6.4V non-isolated
TX906-V3 Volt input, 4 to 64V non-isolated
NB1TX901-(*) NB1 thermocouple probe, 30.5 cm (12") L, 1⁄4" OD,
NB1TX903-(*) NB1 thermocouple probe, 30.5 cm (12") L, 1⁄4" OD,
PRTX904-1 PR-12 RTD probe, 30.5 cm (12") L, 1⁄4" OD,
PRTX904-2 PR-12 RTD probe, 30.5 cm (12") L, 1⁄4" OD,
TX-SCALED Scaling charge for factory set up of range
(specify input type and range from chart above)
Insert thermocouple type J, K, T or E. Contact our custom engineering department for pricing on R or
*
S thermocouples, which are available by special order. Comes complete with operator’s manual.
Notes: (1) Thermocouple model output proportional to mV output of thermocouple. Not linearized
to temperature.(2) For non-isolated units use ungrounded probes. Thermocouple or RTD input
simulation required to scale output for a particular range. To order unit scaled by OMEGA specify
input type, low end of range, high end of range and °F or °C. Specify: TX-SCALED.
Ordering Example: TX901, non-isolated thermocouple transmitter.
and Model No. Overall Input Range
Shown
actual size.
0 to 1370°C (0 to 2500°F)
0 to 1700°C (0 to 3100°F)
0 to 1760°C (0 to 3210°F
0 to 538°C (0 to 1000°F)
ungrounded junction, 304 SS sheath, with TX901
transmitter
ungrounded, 304 SS sheath, with TX903 transmitter
304 SS sheath, with TX904-1 transmitter
304 SS sheath, with TX904-2 transmitter
N-42
Transmitter
inside!
30.5 cm
(12”) probe
shown with
optional
NB3 head.
)
N