⻬ 2.5V Max Voltage Drop
⻬ 8.9 mm (0.35") LCD
⻬ 2000-Count Zero
⻬ 100 to 2000 Count
⻬ Selectable Dummy
⻬ -40 to 85°C Operation
⻬ Compact, 74 mm (2.9")
⻬
⻬ Shock Resistant to 55 g
The TX83A is a 2-wire current-loop
indicator that is powered directly by
a 1 to 5 mA, 4 to 20 mA or 10 to
50 mA process loop signal. No
separate power supply connections
are required. This reduces overall
hardware and field wiring costs and
provides immunity from most
electrical noise encountered in
process control environments. The
electronics are isolated from the case.
Readout of Process Variables
The TX83A provides extensive zero
and span adjustment capability, so
that it can read out directly in
percent or in engineering units for
process variables such as pressure,
TX83A Series
Starts at
$
335
Safety Certification
4 to 20 or 10 to
50 mA Signal
Suppression or Elevation
Span Adjust
Right-Hand Zero
Dia Diecast Housing
Waterproof to 35 kPa (5 psi)
Options
⻬1⁄2 EMT Conduit Fitting
1
⻬
⁄2 NPT Pipe Fitting
⻬ Relay-Track Mounting
Adaptors
⻬ External Explosion-
Proof Housing
⻬ Relay-Track Mounting
TX83A, $335, with EPW3-ATEX
NEMA 4X/7 enclosure, $162.
TX83A, $335.
EPW3-ATEX
housing, $162.
flow, temperature, or level. Its liquid
crystal display provides 31⁄2 active
digits, a selectable dummy right-hand
zero, and 4 programmable decimal
points.
Easy to Configure and Calibrate
Both span and zero are fine-tuned
with precision multi-turn potentiometers.
These are accessible through holes
in the diecast cover, which are
normally sealed with fluorosilicone
plugs.
Designed for Harsh Environments
All versions of the TX83A are rated
for operation from -40 to 85°C
(-40 to 185°F) with specified
accuracy. The case is made of
diecast metal and is waterproof to
35 kPa (5 psi). The electronics are
firmly connected to the case top, so
that the meter can withstand high
vibration and shock.
Intrinsic Safety Certification
Intrinsic safety certification allows the
TX83A to be used in worst-case
hazardous environments with no
M-113
TX83A, $335.
TX84, $355.
All shown smaller
than actual size.
need for an explosion-proof
housing, provided that an intrinsic
safety barrier is used to limit the
voltage and current that may be
introduced in the hazardous
environment. FM certification (USA)
is for class I, II, III, division 1, groups
A, B, C, D, E, F, G. The FM certification
number is 5X2AO.AX (3610).
Explosion-Proof Housing Options
Two external NEMA 7
proof and NEMA 4X
sand-cast, copper-free aluminum
enclosures with corrosion resistance
“safety-blue” polyester powdercoating for use in hazardous
locations. FM, UL, cUL certification:
class I, groups B, C, D; class II,
groups E, F, G; and class III, Type 4X.
Option EPW3 is a single-height
enclosure for one TX83A looppowered indicator. Option EPW2 is
a double-height enclosure for a
TX83A loop-powered indicator on
top and a TX1500 series isolated
2-wire 4 to 20 mA transmitter on the
bottom for indicating transmitter
applications. Available with 2 female
1
⁄2 NPT pipe fittings, all required
internal mounting hardware, and
mounting flanges for a wall or bulkhead.
OMEGACARESMextended
warranty program is available
for models shown on this
page. Ask your sales
representative for full details
when placing an order.
OMEGACARE
labor and equivalent loaners.
explosion-
waterproof,
SM
covers parts,
Page 2
Z
S
4-20mA
transmitter
Control room
receiver
4-20mA loop
Specifications
Input Signal: 1 to 5 mA, 4 to 20 mA or
10 to 50 mA (jumper-selectable)
Linear Range: 0.3 to 50 mA
Protection: 200 mA forward,
1000 mA reverse
Forward Voltage Drop, Max:
2.5 V up to 50 mA
Input Resistance: 50 Ω at 1 to 5 mA,
12.5 Ω at 4 to 20 mA, 5 Ω at 10 to 50 mAZero Adjust: –2000 to 2000 counts
(4 jumper- selectable ranges
plus fine adjustment)
Span Adjust: 0 to 2000 counts
(with fine adjustment)
NMR: 46 dB, 50/60 Hz
CMR (Meter to Case):
120 dB, DC to 60 Hz
CMV (Meter to Case): 700 Vp
RFI Susceptibility: Less than ±0.5%
of span with conduit fitting or external
explosion-proof housing in 10V/m field
strength at 27 or 440 MHz
Accuracy at 25°C
Maximum Error:
±0.1% of span ±1 count 00 zero tempco
±0.1 count/°C typical,
±0.2 count/°C max
Span Tempco: ±0.005% of span/°C
typical, ±0.015% of span/°C max
Polarity: Automatic
Integration Period: 100 ms
Read Rate: 2.5/s
Display
Type: 7-segment LCD
Height: 8.9 mm (0.35")
Symbols: -1.8.8.8.0 (3
plus jumper-selectable dummy righthand zero)
Decimal Points: 4 positions,
jumper-selectable
Overrange: 3 least-significant active
digits blank
Environmental
Operating Temperature:
-40 to 85°C (-40 to 185°F)
Vibration: 1.52 mm (0.06") double-
amplitude cycled at 10 to 80 Hz
Shock: 55 g half-sine, 9 to 13 ms duration
Waterproof Pressure: 35 kPa max (5 psi)
Mechanical
Weight: 14 oz (400 g)
Diameter: 74 mm (2.9")
Height, Including Barrier:
48 mm (1.9")
Electrical Connections:
TX83A: 3-terminal barrier strip with
#6 screws
1
TX84:
⁄2 NPT male pipe fitting
with two 0.3 meter #18 stranded
wires
TX84-2:
1
⁄2" EMT male conduit fitting
with two 0.3 meter #18 stranded
wires
Mounting Methods
TX83A:
• Surface mount with 4 #6 rear-entry
screws from backside of bulkhead
• Snap mount into 63.5 mm
(2.50") relay track
• Surface mount with two #8
front-entry screws
Requires MAT1 adaptor plate
1
⁄2 active digits
• Snap mount into 69.9 mm (2.75")
or 76.2 mm (3.00") relay track
Requires MAT1 adaptor plate.
• Snap mount into DIN relay track
Requires MDT1 rail clamp
• Push mount into explosion proof
The TX83A process-loop indicator may be
added to an existing 4 to 20 mA or
10 to 50 mA installation. No additional
wiring is required, since the meter is
powered directly by the current loop.
housing EPW3-ATEX
AVAILABLE FOR FAST DELIVERY!
To Order (Specify Model Number)
Model No.PriceConfiguration
TX83A$335Flat surface or relay track mounting
TX84355NPT pipe mounting
TX84-2355EMT conduit mounting
Mounting Options (TX83A Only)
OrderAdd’l.
SuffixPrice Description
-MAT1$10 Adaptor plate for
surface mount or
69.9 mm relay track
-MDT115 Rail clamp for
DIN relay track
Accessories
Model No.PriceDescription
MXS1$12Spring retainers for TX83A in explosion
proof housing EPW3
MXS212Spring retainers for TX83A in explosion
proof housing EPW2
EPW3-ATEX162NEMA 4 and NEMA 7 rated environmental enclosure
with window, single height; includes MXS1 hardware
(supplied with Demko/ATEX certificate)
EPW2-ATEX179NEMA 4 and NEMA 7 rated environmental enclosure
with window, double height for TX83A and TX1500
series transmitter; includes MXS1 and MXS2 hardware
(supplied with Demko/ATEX certificate)
Comes complete with operator’s manual.
Ordering Examples: TX84 current loop-indicator with NPT pipe mounting, $355.
OCW-3 OMEGACARESMextends standard 1-year warranty to a total of 4 years ($86),
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters