Omega Products TX83A User Manual

Two-Wire, Process-Loop Indicator
Extended Warranty
Program
SM
F M
APPROVED
Optional NEMA 4X/7 Housing
FM Intrinsic
Powered by 1 to 5,
2.5V Max Voltage Drop8.9 mm (0.35") LCD2000-Count Zero
100 to 2000 Count
Selectable Dummy
-40 to 85°C OperationCompact, 74 mm (2.9")
⻬ ⻬ Shock Resistant to 55 g
The TX83A is a 2-wire current-loop indicator that is powered directly by a 1 to 5 mA, 4 to 20 mA or 10 to 50 mA process loop signal. No separate power supply connections are required. This reduces overall hardware and field wiring costs and provides immunity from most electrical noise encountered in process control environments. The electronics are isolated from the case.
Readout of Process Variables
The TX83A provides extensive zero and span adjustment capability, so that it can read out directly in percent or in engineering units for process variables such as pressure,
TX83A Series
Starts at
$
335
Safety Certification
4 to 20 or 10 to 50 mA Signal
Suppression or Elevation
Span Adjust
Right-Hand Zero
Dia Diecast Housing Waterproof to 35 kPa (5 psi)
Options
⻬1⁄2 EMT Conduit Fitting
1
2 NPT Pipe Fitting
Relay-Track Mounting
Adaptors
External Explosion-
Proof Housing
Relay-Track Mounting
TX83A, $335, with EPW3-ATEX NEMA 4X/7 enclosure, $162.
TX83A, $335.
EPW3-ATEX housing, $162.
flow, temperature, or level. Its liquid crystal display provides 31⁄2 active digits, a selectable dummy right-hand zero, and 4 programmable decimal points.
Easy to Configure and Calibrate
Both span and zero are fine-tuned with precision multi-turn potentiometers. These are accessible through holes in the diecast cover, which are normally sealed with fluorosilicone plugs.
Designed for Harsh Environments
All versions of the TX83A are rated for operation from -40 to 85°C (-40 to 185°F) with specified accuracy. The case is made of diecast metal and is waterproof to 35 kPa (5 psi). The electronics are firmly connected to the case top, so that the meter can withstand high vibration and shock.
Intrinsic Safety Certification
Intrinsic safety certification allows the TX83A to be used in worst-case hazardous environments with no
M-113
TX83A, $335.
TX84, $355.
All shown smaller
than actual size.
need for an explosion-proof housing, provided that an intrinsic safety barrier is used to limit the voltage and current that may be introduced in the hazardous environment. FM certification (USA) is for class I, II, III, division 1, groups A, B, C, D, E, F, G. The FM certification number is 5X2AO.AX (3610).
Explosion-Proof Housing Options
Two external NEMA 7 proof and NEMA 4X sand-cast, copper-free aluminum enclosures with corrosion resistance “safety-blue” polyester powder­coating for use in hazardous locations. FM, UL, cUL certification: class I, groups B, C, D; class II, groups E, F, G; and class III, Type 4X.
Option EPW3 is a single-height enclosure for one TX83A loop­powered indicator. Option EPW2 is a double-height enclosure for a TX83A loop-powered indicator on top and a TX1500 series isolated 2-wire 4 to 20 mA transmitter on the bottom for indicating transmitter applications. Available with 2 female
1
2 NPT pipe fittings, all required internal mounting hardware, and mounting flanges for a wall or bulkhead.
OMEGACARESMextended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARE labor and equivalent loaners.
explosion-
waterproof,
SM
covers parts,
Z
S
4-20mA
transmitter
Control room
receiver
4-20mA loop
Specifications
Input Signal: 1 to 5 mA, 4 to 20 mA or
10 to 50 mA (jumper-selectable)
Linear Range: 0.3 to 50 mA Protection: 200 mA forward,
1000 mA reverse
Forward Voltage Drop, Max:
2.5 V up to 50 mA Input Resistance: 50 at 1 to 5 mA,
12.5 Ω at 4 to 20 mA, 5 at 10 to 50 mA Zero Adjust: –2000 to 2000 counts
(4 jumper- selectable ranges plus fine adjustment)
Span Adjust: 0 to 2000 counts (with fine adjustment)
NMR: 46 dB, 50/60 Hz CMR (Meter to Case):
120 dB, DC to 60 Hz
CMV (Meter to Case): 700 Vp RFI Susceptibility: Less than ±0.5%
of span with conduit fitting or external explosion-proof housing in 10V/m field strength at 27 or 440 MHz
Accuracy at 25°C
Maximum Error:
±0.1% of span ±1 count 00 zero tempco ±0.1 count/°C typical, ±0.2 count/°C max
Span Tempco: ±0.005% of span/°C typical, ±0.015% of span/°C max
Analog-to-Digital Conversion Technique: Dual-slope, average-value
Polarity: Automatic Integration Period: 100 ms Read Rate: 2.5/s
Display
Type: 7-segment LCD Height: 8.9 mm (0.35") Symbols: -1.8.8.8.0 (3
plus jumper-selectable dummy right­hand zero)
Decimal Points: 4 positions, jumper-selectable
Overrange: 3 least-significant active digits blank
Environmental
Operating Temperature:
-40 to 85°C (-40 to 185°F) Vibration: 1.52 mm (0.06") double-
amplitude cycled at 10 to 80 Hz
Shock: 55 g half-sine, 9 to 13 ms duration Waterproof Pressure: 35 kPa max (5 psi)
Mechanical
Weight: 14 oz (400 g) Diameter: 74 mm (2.9") Height, Including Barrier:
48 mm (1.9")
Electrical Connections:
TX83A: 3-terminal barrier strip with
#6 screws
1
TX84:
2 NPT male pipe fitting with two 0.3 meter #18 stranded wires
TX84-2:
1
2" EMT male conduit fitting with two 0.3 meter #18 stranded wires
Mounting Methods
TX83A:
• Surface mount with 4 #6 rear-entry screws from backside of bulkhead
• Snap mount into 63.5 mm (2.50") relay track
• Surface mount with two #8 front-entry screws Requires MAT1 adaptor plate
1
2 active digits
• Snap mount into 69.9 mm (2.75") or 76.2 mm (3.00") relay track Requires MAT1 adaptor plate.
• Snap mount into DIN relay track Requires MDT1 rail clamp
• Push mount into explosion proof
The TX83A process-loop indicator may be added to an existing 4 to 20 mA or 10 to 50 mA installation. No additional wiring is required, since the meter is powered directly by the current loop.
housing EPW3-ATEX
AVAILABLE FOR FAST DELIVERY!
To Order (Specify Model Number)
Model No. Price Configuration TX83A $335 Flat surface or relay track mounting TX84 355 NPT pipe mounting TX84-2 355 EMT conduit mounting
Mounting Options (TX83A Only)
Order Add’l. Suffix Price Description
-MAT1 $10 Adaptor plate for
surface mount or
69.9 mm relay track
-MDT1 15 Rail clamp for
DIN relay track
Accessories
Model No. Price Description MXS1 $12 Spring retainers for TX83A in explosion
proof housing EPW3
MXS2 12 Spring retainers for TX83A in explosion
proof housing EPW2
EPW3-ATEX 162 NEMA 4 and NEMA 7 rated environmental enclosure
with window, single height; includes MXS1 hardware (supplied with Demko/ATEX certificate)
EPW2-ATEX 179 NEMA 4 and NEMA 7 rated environmental enclosure
with window, double height for TX83A and TX1500 series transmitter; includes MXS1 and MXS2 hardware (supplied with Demko/ATEX certificate)
Comes complete with operator’s manual.
Ordering Examples: TX84 current loop-indicator with NPT pipe mounting, $355. OCW-3 OMEGACARESMextends standard 1-year warranty to a total of 4 years ($86),
$355 + 86 = $441.
M-114
Options
Order Add’l. Suffix Price Description
-FS $45 Custom
configuration and calibration
M