Omega Products TX83 Installation Manual

www.omega.com
e-mail: info@omega.com
User’s Guide
TX83 and TX84
Two-Wire Current Loop
Powered Indicators
Shop online at
OMEGAnet®On-Line Service Internet e-mail
www.omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certifica­tion of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it con­tains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
Benelux:
Postbus 8034, 1180 LA Amstelveen The Netherlands Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl
Czech Republic:
Frystatska 184, 733 01 Karvina
´, Czech Republic Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France:
11, rue Jacques Cartier, 78280 Guyancourt, France Tel: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr
Servicing Europe:
USA and Canada:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
USA: ISO 9001 Certified
One Omega Drive, Box 4047 Stamford CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Servicing North America:
For immediate technical or application assistance:
Mexico:
En Espan~ol: (001) 203-359-7803 FAX: (001) 203-359-7807 e-mail: espanol@omega.com
info@omega.com.mx
Germany/Austria:
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: ISO 9002 Certified
One Omega Drive River Bend Technology Centre Northbank, Irlam Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
Canada:
976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
TABLE OF CONTENTS
TX83 AND TX84 TWO-WIRE CURRENT
LOOP INDICATORS
SECTION PAGE
SECTION 1 INTRODUCTION. . . . . . . . . . . . . . . . . . . 1
1.1 General Description . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 2 INSTALLATION 4
2.1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Signal Input Connections . . . . . . . . . . . . . . . . . . 11
2.3.1 TX83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.3.2 TX84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.4 Power Supply Requirements . . . . . . . . . . . . . . . 13
i
TABLE OF CONTENTS (Cont’d)
SECTION PAGE
SECTION 1 CONFIGURATION PROCEDURES. . . 15
3.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2 Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . 15
3.3 Field Set-Up Calculation Procedure . . . . . . . . . . 17
3.4 Alternate Field Set-Up Calculation Procedure . . . 18
3.5 Field Set-Up Procedure implementation . . . . . . . 20
3.6 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.6.1 Equipment Required . . . . . . . . . . . . . . . . . . . . . . 26
3.6.2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
SECTION 4 SPECIFICATIONS . . . . . . . . . . . . . . . 29
ii
SECTION 1 INTRODUCTION
1.1 GENERAL DESCRIPTION
The OMEGA
®
TX-83 and TX-84 are weather resistant digital indicators which accept 1-5 mA, 4-20 mA, or 10-50 mA process input signals. The digital display (±1999 active counts) can present the process variable in either percentage or directly in engineering units. The indicators are powered directly from the current loop with a volt drop of less than 2.5 volts, and a power consumption of 2. 5 mW at 1 mA.
The TX-83 and TX-84 are watertight to 5 PSIG, and have an ambient temperature specification of from
-40 to +85°C making them ideal for locations exposed to “wash-downs” or to the weather. Applications include the measurement of temperature, pressure, flow, PH, or for that matter, the measurement of any process variable for which a current loop transmitter is available.
1
For indoor applications OMEGA offers 1/8 DIN size panel-mount Process Loop Indicators, including the TX-82A. TX82A Indicators, and others, are described in the “L” and “M” Section of the OMEGA Temperature Measurement Handbook.
The TX-83 and TX-84 feature in-field programmability. Coarse input ranges (1-5, 4-20, or 10-mA) are selected by internal shunts. Three decimal points and a dummy right-hand zero may also be selected with pin-forest shunts. Zero and span are fine-tuned with precision 25-turn potentiometers. Positive slope response can be changed to negative slope response (eg., +6000 to -18000) by simply changing two other internal shunts.
The TX-83 and TX-84 are electrically isolated from the case, and are immune to most sources of electrical noise encountered in process-control environments. In the event of input overrange currents, the TX-83 and TX-84 can tolerate 250 mA in the forward direction and 1000 mA reverse.
2
Low mass and multi-point circuit board support give excellent vibration and shock resistance. Sturdy, die­cast construction, polyurethane paint, and full fluorosilicone gasketing ensure a virtually waterproof case. Circuit boards are conformally coated for added humidity protection.
The TX-83 can be mounted in a control room on either American or European relay tracks with snaptrack adapters, mounted directly on a wall with a bulkhead adapter, or mounted in an explosion­proof enclosure for wiring compatibility with other equipment in hazardous environments. The TX-84 may be connected directly to a conduit with a “T” junction box. The TX-83 has barrier strip terminals and the TX-84 has a
1
2" NPT conduit fitting with 12"
lead Wires.
3
1.2 FEATURES
• 3
1
2 Digit Display with Dummy Zero
• Powered Entirely by Signal Loop
• 1 to 5, 4 to 20, or 10 to 50 mA Ranges
• Scalable Zero and Offset for Engineering Units
• High Vibration and Shock Resistant with Cases of
Die-Cast Metal that are Waterproof to 35 kPa (5 psi)
SECTION 2 INSTALLATION
2.1 UNPACKING
Remove the Packing List and verify that all equipment has been received. If there are any questions about the shipment, please call OMEGA Customer Service Department at:
1-800-622-2378 or 203-359-1660.
We can also be reached at:
www.omega.com email: info@omega.com
4
Upon receipt of shipment, inspect the container and equipment for any signs of damage. Take particular note of any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
NOTE
The carrier will not honor any claims unless all shipping material is saved for their examination. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
2.2 MOUNTING
The TX-83 and TX-84 are packaged in a small, rugged, die-cast, zinc-alloy case designed to fit 3" I.D. or larger housings, and requiring less than 2" of height. (Refer to Figure 2-1.)
5
6
Figure 2-1. Outline Dimensions
The TX-83 provides for surface, track, or explosion­proof housing mounting, and is connected with a three-terminal, #6 screw barrier strip. Tapped holes on the back of the TX-83 case provide for custom mounting to a flat surface; integral flanges on the back of the case provide for standard 8TK2 relay track mounting. For flat surface mounting, use #6 hardware For 8TK2 relay track mounting, simply push onto track.
The TX-83 also comes standard with an additional adapter plate for surface mount with two #8 front­entry screws through keyhole slots, or for push­mount Into TR2/2TK relay track.
The TX84 is equipped with a
1
2" NPT conduit fitting. The fitting has two, 0.3 meter long, #18 stranded insulated wires passing through a neoprene moisture plug, for hook-up to junction boxes with standard wire nuts. The TX84-2 is the same as the TX84 with a
1
2" male EMT conduit fitting.
Refer to Figures 2-3a and 2-3b for basic mounting configurations.
7
8
Figure 2-2. Surface and TR2/2TK Relay Track Mounting, Model TX-83
9
Figure 2-3a. Rear View: Standard Integral Mounting Plate (TX-83)
10
Figure 2-3b. Basic Mounting Configurations
2.3 SIGNAL INPUT CONNECTIONS
WARNING
Input currents in excess of protective limits can damage your TX-83/84 Current Loop Indicator.
2.3.1 TX-83
Figure 2-4 below shows a typical TX-83 installation and wiring when used with a two wire transmitter and power supply. Power supply requirements are covered in Section 2-4.
11
12
Figure 2-4. TX-83 and Two-Wire Transmitter Wire
Loading...