Omega Products TRFP240AC User Manual

K-38
TIMING RELAYS
TRFP240AC
$
140
20 Time Ranges and
10 Timing Functions
to 600 hrs
Space-Saving, Compact PackageHigh Repeat Accuracy of ±0.2%LED Indication2 Form C DPDT Delayed
Output Contacts
10 A Contact Rating
The TR Series Timing Relays are designed to meet most timing requirements by offering more flexibility in range of input voltage, timing range and functionality. Use a rotary switch to choose from 20 selectable time ranges from 0.1 second to 600 hours. We offer both a power triggered and signal triggered model—each with expanded operation modes. There is a green LED to indicate when power is ON and an orange LED when output is ON.
SPECIFICATION
Contact Configuration: 2 Form C, DPDT
(delayed output) Allowable Voltage/Current: 240 Vac,
30 Vdc/10 A
Max Permissible Operating Frequency:
1800 cycles per hour Rated Resistive Load: 10 A, 240 Vac/
30 Vdc Rated Inductive Load: 7 A, 240 Vac/
30 Vdc
Horsepower Rating:
1
6 hp 120 Vac, 1⁄3 hp
240 Vac Electrical Life: 500,000 operations min
(resistive) Mechanical Life: 50,000,000
operations minimum Operation System: Solid-state
CMOS circuit
Time Range: 0.1 sec to 600 hours Coil Rating: 100-240 Vac Triggering: By signal
Pollution Degree: 2 (IE60664-1) Overvoltage Category: III (IE60664-1) Rated Operational Voltage:
100 to 240 Vac (50/60 Hz) Voltage Tolerance: 85 to 264 Vac
(50/60 Hz) Input OFF Voltage: Rated Voltage x
10% minimum
Ambient Operating Temperature:
-20 to 65°C (-4 to 149°F)
Reset Time: 100 mS maximum Repeat Error: ±0.2%, ±20 mS Voltage Error: ±0.2%, ±20 mS Temperature Error: ±0.5%, ±20 mS Setting Error: ±10% maximum Insulation Resistance: 100 M
minimum (500 Vdc)
Dielectric Strength Between Power and Output Terminals: 2000 Vac, 1 minute
Dielectric Strength Between Contacts of Different Poles: 2000 Vac, 1 minute
Dielectric Strength Between Contacts of Same Pole: 1000 Vac, 1 minute
Vibration Resistance: 10 to 55 Hz
amplitude 0.5 mm; 2 hrs in each of 3 axes
Shock Resistance: 10 G (operating extremes), 40 G (damage limits 3x in each of 3 axes)
Power Consumption (Approx):
6.5 VA @ 120 Vac/60 Hz, 11.6 VA @ 240 Vac/60 Hz
Dimensions: 40 H x 36 W x 77.9 mm D (1.58 x 1.42 x 3.07")
Weight: 89 g (3 oz)
TUV
TRFP240AC, $140, shown larger than actual size.
D3PA3, $8, shown smaller than actual size.
K-39
Comes with installation guide.
Ordering Example: TRFP240AC, timing relay, with D3PA3 socket, $140 + 8 = $148
MODEL NO. PRICE DESCRIPTION
TRFP240AC $140 Timing relay, 100-240 Vac coil voltage, signal triggered D3PA3 8 11-pin octal socket
To Order
(Specify Model Number)
AVAILABLE FOR FAST DELIVERY!
B: Cycle (Signal Start, OFF First) When the start input turns on while power is on, the output oscillates at a preset cycle (Duty Ratio 1:1), starting while the NO contact off.
C: Cycle (Signal Start, ON First) When the start input turns on while power is on the NO contact goes on. The output oscillates at a preset cycle (Duty Ratio 1:1).
D: Signal ON/OFF-Delay When the start input turns on while power is on, the NO output contact goes on. When a preset time has elapsed while the start input remains on, the output contact goes off. When the start input turns off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the NO contact goes off
E: Signal OFF-Delay When power is turned on while the start input is on, the NO output contact goes on. When a preset time has elapsed after the start input turned off, the NO output contact goes off.
F: One-Shot (Signal Start) When the start input turns on while power is on, the NO output contact goes on. When a preset time has elapsed, the output contact goes off.
Ta
TTTTTTT
T
Operation
Set Time
Terminal No.Item
2-10
(NC)
1-4, 8-11
(NO)
1-3, 9-11
OUT
PWR
Delayed
Contact
Power
Indicator
5-6
Start
A: ON-Delay (Signal Start) When a preset time has elapsed after the start input turned on while power is on, the NO output contact goes on
OPERATION
Power
Delayed
Contact
Indicator
Set Time
Start
Terminal No.Item
1-4, 8-11
1-3, 9-11
PWR
OUT
Operation
2-10
5-6
(NC)
(NO)
TTa
Power
Delayed
Contact
Indicator
Set T ime
Note: T=Set T ime, T a=Shorter Than Set T ime
Start
Terminal No.Item
1-4, 8-11
1-3, 9-11
PWR
OUT
2-10
5-6
(NC)
(NO)
Internal Connections
External Control Signal
4
3
210
(
/+)
Start
5
TRFP
6
111
7
8
9
(/
Operation
Ta
-
)
TaTT
Power
Delayed
Contact
Indicator
Set Time
Start
Terminal No. OperationItem
1-4, 8-11
1-3, 9-11
PWR
OUT
2-10
5-6
(NC)
(NO)
TTTTTTTTT
Ta
Power
Delayed
Contact
Indicator
Set Time
Start
Terminal No. OperationItem
1-4, 8-11
1-3, 9-11
PWR
OUT
2-10
5-6
(NC)
(NO)
TT TT
TaTa
Power
Delayed Contact
Indicator
Set Time
Start
Terminal No. OperationItem
2-10
1-4, 8-11
1-3, 9-11
PWR
OUT
5-6
(NC)
(NO)
T
Ta
Loading...
+ 1 hidden pages