Omega Products OS523 User Manual

5
6
QUICK START
VISUAL FUNCTION FLOW CHART
LCK
LAL
ATC
HAL
MODE MODEDISPLAY DISPLAY
LCK
LCK
LCK
LCK
LCK
LCK
LCK
LCK
LCK
LCK
(Model OS533)
LCK
(Model OS531, OS532 OS530L, OS530HR)
While in these 5 modes:
Use key to change temperature from °F to °C or vice versa.
Use key to turn on the display backlighting.
AVOID EXPOSURE
LASER RADIATION
IS EMITTED FROM
THIS APERTURE
LASER RADIATION - DO NOT STARE INTO BEAM
OUTPUT <1 mW, WAVELENGTH 630-670 nm CLASS II (2) LASER PRODUCT, COMPLIES WITH FDA 21CFR 1040.10 & EN60825-1/11.2001
®
OMEGASCOPE
CAUTION
Warning and Certification Label
CAUTION: Use of controls or adjustments
or performance of procedures other than those specified here may result in hazardous radiation exposure. Refer to the Operator’s Manual for complete warnings and cautions.
OMEGASCOPE
®
Handheld Infrared Thermometer
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
PATENT NOTICE: U.S. PAT. D357,194, B1 5,368,392, 5,524,984, 5,727,880, 5,465,838 5,823,678, 5,823,679, 6,267,500B1, 6,123,453, 6,341,891B1/Canada 75811 D OMEGA ENGINEERING, INC., 2,116,055, 2,114,806/Czech Republic 25372/France 0378411 to 0378446, 2,767,921, 2 773 213 B1/Germany M 94 06
478.4, G 94 22 197.9, G 94 22 203.7/Italy RM940000913/Japan 988,378/ Netherlands 1007752, 25009-00/Spain mod. ut. 133292/Slovak Republic 24565/U.K. Registered 2041153, 9726133.3, EPO 0 644408, EP 1 085 307 A1 Other U.S. and International Patents Pending.
MQS2891-0903
OS531 OS532 OS533 OS534 OS530L OS530HR OS53x-CF OS523 OS524
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase of the base unit and 13 months from date of purchase on Laser Sight Module. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA's WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear are not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use if its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
FOR WARRANTY
RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under
which the product was PURCHASED,
2. Model and serial number of
the product under warranty, and
3. Repair instructions and/or
specific problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair or calibration,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2006 OMEGA ENGINEERING, INC. All rights reserved.
This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
3. Press the key to lock the trigger. The icon will appear. This allows the thermometer to
operate continuously whether or not the trigger is pulled. To unlock the trigger, press the key
again.
4. To complete a temperature measurement, release the trigger; the thermometer goes into sleep mode.
NOTE: If the icon flashes and the unit beeps intermittently, the batteries must be replaced with fresh batteries immediately.
Servicing North America:
U.S.A.: One Omega Drive, P.O. Box 4047
ISO 9001 Certified
Stamford. CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico: En Espan˜ol: (001) 203-359-7803
FAX: (001) 203-359-7807 e-mail: espanol@omega.com info@omega.com.mx
Servicing Europe:
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified
Northbank, Irlam, Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
OMEGAnet®On-Line Service Internet e-mail
omega.com info@omega.com
For latest product manuals: omegamanual.info
Using this Quick Start Manual
Use this Quick Start Manual with your OS530/OS520 series Handheld Infrared Thermometer to set it up and perform basic operations. These tasks are:
Installing the Batteries
Operating the Laser Sight
Taking Temperature Readings
Display Mode Sequence For detailed information, refer to the
User’s Guide (M2891).
Getting Started
Parts of the Thermometer
Figure 1. Front of the Thermometer
Figure 2. Rear of the Thermometer
Laser Beam
Aperture
Identification Label
(bottom)
Tripod Thread
Mount
Analog Output Jack (1mV/deg)
ac Adapter Input Jack
RS-232 Phone Jack
(OS533, OS534, OS523, OS524)
Thermocouple Input
Socket (SMP)
Laser Dot/Circle Switch
Figure 9. OS534/OS523-1 Field of View
Figure 10. OS53x-CF Field of View
Figure 11. OS523-2 Field of View
Figure 12. OS523-3 Field of View
8.7"
0.5"@ 0
5.1"
13mm @ 0
1.5"
38
130
221
0.9"
0' 16' 82'50'
*SPOT DIAMETER MEASURED
AT 90% ENERGY
D:S
=
110:1
25
0
5 15
DISTANCE: SENSOR TO OBJECT (FT)
SPOT DIA.* (MM)
SPOT DIA.* (IN)
DISTANCE: SENSOR TO OBJECT (M)
7.0"
.35"@ 24"
1.6"
9mm @ 610mm
.8"
21
42
181
.9"
22
4.0"
101
0’
3’
16’10’2’ 5’
SPOT DIA.* (MM)
*SPOT DIAMETER MEASURED
AT 90% ENERGY
5.0
0
.61
1.5
1.0
3.0
SPOT DIA.* (IN)
DISTANCE: SENSOR TO OBJECT (FT)
DISTANCE: SENSOR TO OBJECT (M)
2.9"
0.9"@ 0
1.9"
22mm @ 0
1.2"
1.0"
31
26
48
75
0.9"
0'
3'
16'10'
*SPOT DIAMETER MEASURED
AT 90% ENERGY
D:S
=
60:1
5'
5.0
0
1.0 3.01.5
SPOT DIA.* (MM)
SPOT DIA.* (IN)
DISTANCE: SENSOR TO OBJECT (FT)
DISTANCE: SENSOR TO OBJECT (M)
.45"
11.5
3"
SPOT DIA.* (MM)
*SPOT DIAMETER MEASURED
AT 90% ENERGY
7.6
SPOT DIA.* (IN)
DISTANCE: SENSOR LENS TO OBJECT (in.)
DISTANCE: SENSOR LENS TO OBJECT (cm.)
15.2
6"
9"12"
15"
.15"
.39"
.78"
1.17"
3.9
9.9
19.9
29.9
D:S = 40:1
22.9
30.5
38.1
0.9"
22
0
0
Taking Temperature Readings
1. Aim at the target. If you are not using the Laser Sighting, use the “V” groove on top of the thermometer to align the target to the thermometer’s field of view.
Figure 6. Field of View Positions
2. Pull and hold the trigger. To use the laser sighting, set the laser power switch to the ON position. The Power Indicator LED and the laser beam will turn on. The laser beam will stay on as long as the trigger is pulled. The target temperature and emissivity (E) will be displayed on the LCD. You can
press the or key to increment or decrement the target emissivity.
Figure 7. OS531, OS532, OS530L Field of View
Figure 8. OS533, OS530HR Field of View
4.8"
1.0" @ 0" to 20"
2.5cm @ 51cm
1.2"
1.0"
2.5
6.0
4.0
8.0
10.0
12.2
1601208040
1.0"
1.8"
2.4"
3.0"
3.6"
4.2"
1' 2'
200
8'6'
0**
DISTANCE: SENSOR TO OBJECT (FT)
DISTANCE: SENSOR TO OBJECT (CM)
SPOT DIA.* (IN)SPOT DIA.* (CM)
*SPOT DIAMETER MEASURED
AT 90% ENERGY
D:S = 20:1
4'
244
3' 5' 7'
20"
Field of View
Target
(ACCEPTABLE)
(UNACCEPTABLE)
START HERE
2
3
4
Parts of the Display
Figure 3. Display and Keypad View
Installing the Batteries
Invert the unit and install 4 fresh AA size batteries as shown in Figure 4.
Figure 4. Installing the Batteries
ac Operation
The thermometer may be operated on ac power using the optional ac adapter. 120Vac/60 Hz and 220Vac/50 Hz adapters are available.
Operating the Laser Sight Module
WARNING: DO NOT AIM THE LASER BEAM AT
ANYONE’S EYES.
The laser sight module is built into the thermometer. Set the laser power switch to the ON position.
Figure 5. Two Laser Configurations
The thermometer is ready for operation.
2 Types of Laser Beams
Laser Dot
Laser Circle
LCK
HAL
LOBAT
ATC
LAL
PRN
°F °C
Display
Mode
Data
Associated with
Display Mode
Backlighting
Icon
Unit of
Measure
Main Display Temperature
Locks
Trigger/
Enables
Alarms
Increments
Data/
Backlighting
ON/OFF
Display
Icons
Scrolls through Display
Modes
Decrements
Data/
°F to °C or
°C to °F
** Measurement distance is from the outside surface of the rubber boot.
Loading...