The OS1562 and OS1572 are stand-alone fiber optic infrared sensor for applications requiring the advantages of non-contact temperature measurement and fiber optic technology. They are used where conventional infrared detectors are not possible, such as with targets which are not easy to access, have small spot sizes, are in high energy fields or are in environments with high humidity or containing smoke, or in vacuum applications.
Some important factors that determine the fiber optic assembly needed with the sensors are: the
distance from the fiber optic probe lens to the surface being measured; the size of object; the temperature range; the ambient temperature range around the fiber optics; the length of fiber optic cable; the method of heating the surface being measured; and the atmospheric conditions between the fiber optic lens and the product.
The ordering matrix shows a few configurations of the sensors with fiber optic probe assemblies. Consult OMEGA for other available fiber optic assembly configurations. All systems include sensor, fiber optic probe, and fiber optic cable.
Additional Assemblies Available Consult Engineering
• Small Spot Sizes Down to 0.004"
• Temperatures to 800°F at Pressures to 30,000 PSI
• Ceramic/Metal Tip Probe for Induction Heating Where Probe Is Close to Surface
• Polymer Bolt Probe for Extrusion Applications
• Ejector Pin Probe for Injection Molding
Temperature Ranges
to 1825°C (3320°F)
±1.0%AccuracyTime Constant
10 msec (0 to 63.2%)
Small Spot Sizes
Down to 0.020" at 6"
1 mV/Degree
Output Standard
Unaffected by
Electrical Noise
Emissivity Adjustment
for High Accuracy Measurements
Fiber Optic Vacuum
Bushing Good for 10
-7
Torr
Optional Backlighting
For Precise Sighting
L1 Standard ProbeAvailable Second
Output: 0 to 10 Vdc, 4 to 20 mA, J or K Thermocouple Signal
Signal Processing
Available with OS1572
Fast Response Fiber Optic Infrared Sensors
OS1562/OS1572
Starts at
$
2400
OS1562F-L1-R1-4, $2460,
shown smaller than
actual size.
OS1562-MB mounting
bracket included.
L1 lens probe type
Page 2
J-114
J
1 mV PER
DEGREE
OS1562 OS1572
FIBER OPTIC CABLE
FIBER OPTIC ASSEMBLY
LENS PROBE
CERAMIC OR
METAL TIP
POLYMER BOLT
PROBE
EJECTOR PIN
PROBE
L1
L2
L3
L4
MOST POPULAR ASSEMBLY LENS IMAGES TARGET ON FIBER TIP
FOR PLASTIC EXTRUDERS
FOR INDUCTION HEATERS
FOR REMOVING AN INJECTION MOLDING PART
TARGET
To Order
(Specify Model Number)
Base Temp. Spot Size @ Cable Output Signal
Model No. Price Range Target Dist. Length Signal(s) Processi
ng
OS1562F-L1-R1 $2460 850 to 1800°F 0.020"@6" 1.2 m (4') N/A
OS1562F-L1-R2 2400 400 to 850°F 0.085"@6" 0.3 m (1') N/A
OS1562F-L1-R3 2460 400 to 850°F 0.22"@8" 1.2 m (4') N/A
OS1562C-L1-R4 2460 900 to 1825°C 1.0"@26" 1.2 m (4') N/A
OS1572F-L1-R1 3500 1600 to 3320°F 0.020"@6" 1.2 m (4')
OS1572F-L1-R2 3460 400 to 850°F 0.085"@6" 0.3 m (1') optional
OS1572F-L1-R3 3500 450 to 1000°F 0.22"@8" 1.2 m (4') see table
OS1572C-L1-R4 3500 800 to 1550°C 1.0"@26" 1.2 m (4')
Comes with sensor probe assembly, fiber optic cable, mounting bracket and operator’s manual. Ordering Examples: OS1572F-L1-R3-4-MA-SA, fiber optic infrared sensor, 450 to 1000°F range, 0.22" spot size at 8", 1.2 m (4') cable,
with 4 to 20 mA and signal advertising, $3500 + 125 + 330 = $3995. OS1562F-L1-R1-4, fiber optic infrared sensor, 850 to 1800°F range, 0.020" spot size at 6", 1.2 m (4') cable, with 1 mV/° output,
and Type J thermocouple output, $2460.
Model No. Price Description PSS-D15B $114 ±15 Vdc or 30 V regulated power supply, ±100 mA,
0.02% line and load, 115 Vac input
OS1562-MB 95 Additional mounting bracket
Accessories
Consult OMEGA for custom vacuum bushings and other OS1562 or OS1572 fiber optic systems.
Specifications
Ambient Temperature: 10 to 50°C
(50 to 122°F)
Accuracy: ±1.0% rdg Repeatability: ±0.5% rdg Emissivity: 0.05 to 1.0 adjustable
in 0.01 steps
Spectral Response:
0.91 to 2.8 microns
Time Constant: 10 msec, (0 to 63.2%) Signal Output:
1 mV/degree standard
Resolution: 1°C/°F Power: ±15 Vdc, 100 mA regulated
supply 0.05% line and load
Power Consumption: 2 W max Dimensions:
OS1562: 6.9 H x 10.2 W x 30.5 cm D
(2.7 x 4.0 x 12")
Weight: 1.8 kg (4 lb) Fiber Optic Cable: Glass or quartz
fiber with heavy duty s.s. jacket standard, 0.5 mm/1.78 mm (0.020"/.070") cable dia, 300°F ambient max
OS1562F-L1-R1-4, $2460, shown smaller than actual size.
Available Probe Types L1 Lens Probe (Standard) L2 Ceramic/Metal Tip L3 Polymer Bolt L4 Ejector Pin Probe
L1
L4
L2
L3
1 mV/°
standard
2nd output
optional,
see table
Optional Second Output (OS1562 Models – No Add’l Cost)
Order Suffix Description
-V 0 to 10 Vdc
-MA 4 to 20 mA
-J J thermocouple
-K K thermocouple
Optional Second Output (OS1572 Models)
Order Add’l Suffix Price Description
-V $75 0 to 10 Vdc
-MA 125 4 to 20 mA
Optional Signal Processing Feature (OS1572 Models)
Order Add’l Suffix Price Description
-PS $330 Peak sense/hold
-SA 330 Signal advertising
-FR 330 Fast rise variable
decay
L1 shown with optional bifurcated cable for backlighting.
MOST POPULAR MODELS HIGHLIGHTED!
Page 3
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...