Omega Products OM-USB-5203 User Manual

8-Channel Temperature/Voltage Input USB Data Acquisition Modules
OM-USB-TEMP,
shown smaller than
actual size.
Models OM-USB-TEMP
and OM-USB-5203 have 8 Temperature Inputs
Model OM-USB-TEMP-AI
has 4 Temperature Inputs and 4 Analog Voltage Inputs
Temperature Inputs are
Software Programmable for Thermocouple, RTD, Thermistor or Semiconductor Temperature Sensors
Model OM-USB-5203 has
Data Logging Capability (Compact Flash)
24-Bit Resolution Built-In Cold Junction
Compensation and Open Circuit Detection for Thermocouple Inputs
Eight Digital I/ONo External Power Supply
Required (Except for OM-USB-5203)
The OM-USB-TEMP, OM-USB-TEMP-AI and OM-USB-5203 are USB 2.0 full speed temperature input data acquisition modules (fully compatible with both USB 1.1 and USB 2.0 ports).
These are plug-and-play modules which draw power from the USB cable–no external power supply is required (except for OM-USB-5203 which requires an ac adaptor). All configurable options are software programmable, and the modules are fully software calibrated.
To Order, Call or Shop Online at omega.com
The OM-USB-TEMP and OM-USB-5203 provide eight differential temperature input channels. The OM-USB-TEMP-AI provides eight analog input channels that are configured as four differential temperature inputs and four differential or single-ended voltage inputs.
Temperature inputs are software programmable for different sensor types including type J, K, T, E, R, S, B, N thermocouples, 2, 3 or 4-wire Pt100 RTDs, 2, 3 or 4-wire thermistors and semi-conductor sensors and are configured in blocks of two channels. A different type of sensor (thermocouple, RTD, thermistor, semiconductor) can be connected to each block of two channels (both channels must be the same type).
If the block of two channels is set up for thermocouple inputs, it is possible to mix thermocouple types. For example, an OM-USB-TEMP can be configured for 4 RTD inputs and 4 thermocouple inputs but not for 3 RTD inputs and 5 thermocouple inputs.
These modules have integrated cold junction compensation (CJC), linearization and open circuit detection for thermocouple measurements (OM-USB-TEMP and OM-USB-5203 have two integrated CJC sensors and the
OM-USB-TEMP,
OM-USB-TEMP-AI and
OM-USB-TEMP-AI has one CJC sensor. Voltage inputs (OM-USB­TEMP-AI only) are software programmable for ±10V, ±5V, ±2.5V and ±1.25V ranges.
Eight independent, TTL-compatible digital I/O channels are provided to monitor TTL-level inputs, communicate with external devices and to generate alarms. The digital I/O channels are software programmable for input or output.
The OM-USB-5203 features eight independent temperature alarms. Each alarm controls an associated digital I/O channel as an alarm output. The input to each alarm is any one of the temperature input channels.
The output of each alarm is software configurable as active high or low. The temperature threshold condition to activate each alarm is user programmable. When an alarm is activated, the associated digital I/O channel is driven to the output state.
SM
1
The OM-USB-5203 also has data logging capability. Measurements can be logged to a standard CompactFlash memory card (a 512 MB CompactFlash memory card is included with the OM-USB-5203). Data logging can only be done when the OM-USB-5203 is disconnected from the computer. External power is required for data logging via the included ac adaptor. User programmable settings in data logging mode include sampling
OM-USB-TEMP-AI,
shown smaller than
actual size.
interval and logging start mode (on power up, on button press or at a specified data and time).
The OM-USB-TEMP, OM-USB-TEMP-AI and OM-USB-5203 modules ship with an impressive array of software, including the new TracerDAQ®, a full-featured, out-of-the-box data logging, viewing, and analysis application; Universal Library™; ULx for NI LabVIEW (comprehensive library of VIs and example programs compatible with LabVIEW v.8.2.1 and later); and InstaCal™ installation, calibration, and test utility—powerful software solutions for programmers and nonprogrammers alike. These modules operate under Microsoft Windows 2000/XP/VISTA (32-bit or 64-bit) /7 (32-bit or 64-bit) operating systems.
The OM-USB-TEMP, OM-USB-TEMP-AI and OM-USB-5203 data acquisition
Strip Chart
Feature TracerDAQ TracerDAQ PRO
Channel Types
Number of Channels Number of Lanes Maximum Samples
Per Channel Alarm Conditions Measurements Window Enter Annotations Software Triggering Hardware Triggering Time-of-Day Triggering Linear Scaling
Analog Input, Temperature Analog Input, Temperature Temperature Input, Digital Input, Digital Input,
Input, Event Counter Event Counter
8 48 28
32,000 1 milllion
No Yes No Yes No Yes No Yes No Yes No Yes No Yes
Oscilloscope
Feature TracerDAQ TracerDAQ PRO Channel Type Analog input Analog input Number of Channels 24 Measurements Window No Yes Reference Channel No Yes Math Channel No Yes
modules are supplied with TracerDAQ software which is a collection of four virtual instrument applications used to graphically display and store input data and generate output signals:
• Strip Chart—log and graph values acquire from analog inputs, digital inputs, temperature inputs and counter inputs.
• Oscilloscope—display values acquired from analog inputs
• Function generator—generate waveforms for analog outputs
• Rate Generator—generate waveforms for counter outputs
TracerDAQ PRO is an enhanced version of TracerDAQ. A comparison of some of the feature included in TracerDAQ vs TracerDQ PRO is shown.
2
To Order, Call or Shop Online at omega.com
Function Generator
Feature TracerDAQ TracerDAQ PRO Channel Type Analog output Analog output Number of Channels 1 16
Waveform Types Sine
Duty Cycle No Yes Phase No Yes Gate Ratio No Yes Rate Multiplier No Yes Sweep (Linear and
Exponential) No Yes
Sine, square, triangle,
flat, pulse, ramp,
random, Arbitrary
Rate Generator
Feature TracerDAQ TracerDAQ PRO Channel Type Counter output Counter output Number of Channels 1 20
SM