Omega Products OM-USB-5203 User Manual

8-Channel Temperature/Voltage Input USB Data Acquisition Modules
OM-USB-TEMP,
shown smaller than
actual size.
Models OM-USB-TEMP
and OM-USB-5203 have 8 Temperature Inputs
Model OM-USB-TEMP-AI
has 4 Temperature Inputs and 4 Analog Voltage Inputs
Temperature Inputs are
Software Programmable for Thermocouple, RTD, Thermistor or Semiconductor Temperature Sensors
Model OM-USB-5203 has
Data Logging Capability (Compact Flash)
24-Bit Resolution Built-In Cold Junction
Compensation and Open Circuit Detection for Thermocouple Inputs
Eight Digital I/ONo External Power Supply
Required (Except for OM-USB-5203)
The OM-USB-TEMP, OM-USB-TEMP-AI and OM-USB-5203 are USB 2.0 full speed temperature input data acquisition modules (fully compatible with both USB 1.1 and USB 2.0 ports).
These are plug-and-play modules which draw power from the USB cable–no external power supply is required (except for OM-USB-5203 which requires an ac adaptor). All configurable options are software programmable, and the modules are fully software calibrated.
To Order, Call or Shop Online at omega.com
The OM-USB-TEMP and OM-USB-5203 provide eight differential temperature input channels. The OM-USB-TEMP-AI provides eight analog input channels that are configured as four differential temperature inputs and four differential or single-ended voltage inputs.
Temperature inputs are software programmable for different sensor types including type J, K, T, E, R, S, B, N thermocouples, 2, 3 or 4-wire Pt100 RTDs, 2, 3 or 4-wire thermistors and semi-conductor sensors and are configured in blocks of two channels. A different type of sensor (thermocouple, RTD, thermistor, semiconductor) can be connected to each block of two channels (both channels must be the same type).
If the block of two channels is set up for thermocouple inputs, it is possible to mix thermocouple types. For example, an OM-USB-TEMP can be configured for 4 RTD inputs and 4 thermocouple inputs but not for 3 RTD inputs and 5 thermocouple inputs.
These modules have integrated cold junction compensation (CJC), linearization and open circuit detection for thermocouple measurements (OM-USB-TEMP and OM-USB-5203 have two integrated CJC sensors and the
OM-USB-TEMP,
OM-USB-TEMP-AI and
OM-USB-TEMP-AI has one CJC sensor. Voltage inputs (OM-USB­TEMP-AI only) are software programmable for ±10V, ±5V, ±2.5V and ±1.25V ranges.
Eight independent, TTL-compatible digital I/O channels are provided to monitor TTL-level inputs, communicate with external devices and to generate alarms. The digital I/O channels are software programmable for input or output.
The OM-USB-5203 features eight independent temperature alarms. Each alarm controls an associated digital I/O channel as an alarm output. The input to each alarm is any one of the temperature input channels.
The output of each alarm is software configurable as active high or low. The temperature threshold condition to activate each alarm is user programmable. When an alarm is activated, the associated digital I/O channel is driven to the output state.
SM
1
The OM-USB-5203 also has data logging capability. Measurements can be logged to a standard CompactFlash memory card (a 512 MB CompactFlash memory card is included with the OM-USB-5203). Data logging can only be done when the OM-USB-5203 is disconnected from the computer. External power is required for data logging via the included ac adaptor. User programmable settings in data logging mode include sampling
OM-USB-TEMP-AI,
shown smaller than
actual size.
interval and logging start mode (on power up, on button press or at a specified data and time).
The OM-USB-TEMP, OM-USB-TEMP-AI and OM-USB-5203 modules ship with an impressive array of software, including the new TracerDAQ®, a full-featured, out-of-the-box data logging, viewing, and analysis application; Universal Library™; ULx for NI LabVIEW (comprehensive library of VIs and example programs compatible with LabVIEW v.8.2.1 and later); and InstaCal™ installation, calibration, and test utility—powerful software solutions for programmers and nonprogrammers alike. These modules operate under Microsoft Windows 2000/XP/VISTA (32-bit or 64-bit) /7 (32-bit or 64-bit) operating systems.
The OM-USB-TEMP, OM-USB-TEMP-AI and OM-USB-5203 data acquisition
Strip Chart
Feature TracerDAQ TracerDAQ PRO
Channel Types
Number of Channels Number of Lanes Maximum Samples
Per Channel Alarm Conditions Measurements Window Enter Annotations Software Triggering Hardware Triggering Time-of-Day Triggering Linear Scaling
Analog Input, Temperature Analog Input, Temperature Temperature Input, Digital Input, Digital Input,
Input, Event Counter Event Counter
8 48 28
32,000 1 milllion
No Yes No Yes No Yes No Yes No Yes No Yes No Yes
Oscilloscope
Feature TracerDAQ TracerDAQ PRO Channel Type Analog input Analog input Number of Channels 24 Measurements Window No Yes Reference Channel No Yes Math Channel No Yes
modules are supplied with TracerDAQ software which is a collection of four virtual instrument applications used to graphically display and store input data and generate output signals:
• Strip Chart—log and graph values acquire from analog inputs, digital inputs, temperature inputs and counter inputs.
• Oscilloscope—display values acquired from analog inputs
• Function generator—generate waveforms for analog outputs
• Rate Generator—generate waveforms for counter outputs
TracerDAQ PRO is an enhanced version of TracerDAQ. A comparison of some of the feature included in TracerDAQ vs TracerDQ PRO is shown.
2
To Order, Call or Shop Online at omega.com
Function Generator
Feature TracerDAQ TracerDAQ PRO Channel Type Analog output Analog output Number of Channels 1 16
Waveform Types Sine
Duty Cycle No Yes Phase No Yes Gate Ratio No Yes Rate Multiplier No Yes Sweep (Linear and
Exponential) No Yes
Sine, square, triangle,
flat, pulse, ramp,
random, Arbitrary
Rate Generator
Feature TracerDAQ TracerDAQ PRO Channel Type Counter output Counter output Number of Channels 1 20
SM
SPECIFICATIONS
ANALOG INPUTS A/D Converter:
OM-USB-TEMP/OM-USB-5203:
Four dual 24-bit sigma delta A/D converters OM-USB-TEMP-AI: Dual 24-bit
sigma-delta A/D converters Input Isolation: 500 Vdc min between field wiring and USB interface
Number of Channels:
OM-USB-TEMP/OM-USB-5203:
8 differential temperature inputs
OM-USB-TEMP-AI: 4 differential
temperature inputs and
4 differential or single-ended
voltage inputs Thermocouple Input: Software programmable for type J, K, T, E, R, S, B, N Pt100 RTD Input: 2, 3 or 4-wire DIN 43760, = 0.00385, SAMA,
= 0.003911, ITS-90/IEC751, = 0.0038505
Thermistor Input: 2, 3 or 4-wire standard 2252 through 30,000
Semiconductor Sensor:
TMP36 or equivalent
Maximum Input Voltage:
Temperature inputs; ±25V (power on), ±40V (power off): voltage inputs; ±25V (power on), ±15V (power off) Throughput Rate: 2 samples/sec max for all active channels
Input Impedance:
Temperature inputs; 5 G (power on), 1 M(power off): voltage inputs; 10 G (power on), 2.49 K (power off)
Input Leakage Current:
Thermocouples inputs; 105 nA max (with open thermocouple detection enabled), 30 nA max (with open thermocouple detection disabled): voltage inputs; ±1.5 nA typ,
±25 nA max
Maximum Working Voltage (OM-USB-TEMP-AI Voltage Inputs): ±10.25V
max (input signal
Thermistor Measurement Accuracy
+ common mode)
Common Mode
Thermistor Temperature Range OM-USB-5203 OM-USB-TEMP-AI
Rejection Ratio:
Temperature inputs, 100 dB min; voltage inputs, 83 dB min
Warm-Up Time:
30 minutes max
2252 -40 to 120ºC (-40 to 248ºF) ± 0.05 ± 0.001 @ -40ºC, ±3.47 @ 120ºC 3000 -40 to 120ºC (-40 to 248ºF) ± 0.05 ­5000 -35 to 120ºC (-31 to 248ºF) ± 0.05 ± 0.001 @ -35ºC, ±1.54 @ 120ºC 10000 -25 to 120ºC (-13 to 248ºF) ± 0.05 ± 0.001 @ -25ºC, ±0.77 @ 120ºC 30000 -10 to 120ºC (14 to 248ºF) ± 0.05 ± 0.001 @ -10ºC, ±0.27 @ 120ºC
To Order, Call or Shop Online at omega.com
Compatible Thermocouple Input Types
Type Temperature
Range OM-USB-TEMP
OM-USB-TEMP-AI OM-USB-5203
-210 to 1200°C (-346 to 2192°F) ±0.28 @ 0°C ±0.31 (0 to 1200°C)
-210 to 1372°C (-346 to 2502°F) ±0.28 @ 0°C ±0.35 (0 to 1372°C)
-200 to 400°C (-328 to 752°F) ±0.29 @ 0°C ±0.26 (0 to 400°C)
-200 to 1000°C (-328 to 1832°F) ±0.32 @ 0°C ±0.25 (0 to 1000°C)
-50 to 1768°C (-58 to 3214°F) ±0.19 @ 250°C ±0.36 (250 to 1768°C)
-50 to 1768°C (-58 to 3214°F) ±0.20 @ 250°C ±0.40 (250 to 1768°C)
250 to 1820°C (482 to 3308°F) ±0.82 @ 700°C ±0.37 (700 to 1820°C)
-200 to 1300°C (-328 to 2372°F) ±0.28 @ 0°C ±0.27 (0 to 1000°C)
Includes cold junction compensation measurement error. Dependent on A/D data rate.
*
Accuracy* (Typical, °C)
±0.71 @ -210°C ±0.51 (-210 to 0°C)
±0.29 @ 1200°C
±0.76 @ -210°C ±0.54 (-210 to 0°C)
±0.39 @ 1372°C
±0.74 @ -200°C ±0.51 (-200 to 0°C)
±0.21 @ 400°C
±0.68 @ -200°C ±0.46 (-200 to 0°C)
±0.24 @ 1000°C
±0.46 @ -50°C ±0.65 (-50 to 250°C)
±0.13 @ 1768°C
±0.44 @ -50°C ±0.65 (-50 to 250°C)
±0.16 @ 1768°C
±2.19 @ 250°C ±0.58 (250 to 700°C)
±0.47 @ 1820°C
±0.76 @ -200°C ±0.50 (-200 to 0°C)
±0.25 @ 1300°C
Semiconductor Sensor Measurement Accuracy
Sensor Type Temperature Range Maximum Error
TMP36 or Equivalent -40 to 150ºC (-40 to 302ºF) ± 0.50ºC
DC Voltage Input Ranges
Open Thermocouple Detection:
automatically enabled when a channel is configured for a thermocouple sensor CJC Sensor Accuracy: ±0.25ºC typical, ±0.5ºC max (15 to 35ºC);
-1.0 to 0.75ºC max (0 to 70ºC)
RTD Measurement Accuracy
OM-USB-TEMP
Temperature Range OM-USB-5203 OM -USB-TEMP-AI
Typical Error (°C) Typical Error (°C)
-200 to -150ºC (-328 to -238ºF) ± 2.59 ± 2.78 @-200ºC, ±1.07 @-150ºC
-150 to -100ºC (-238 to -148ºF) ± 0.97 ± 1.07 @-150ºC, ±0.35 @-100ºC
-100 to 0ºC (-148 to 32ºF) ± 0.31 ± 0.35 @-100ºC, ±0.12 @0ºC 0 to 100ºC (32 to 212ºF) ± 0.11 ± 0.12 @ 0ºC, ±0.13 @ 100ºC 100 to 300ºC (212 to 572ºF) ± 0.12 ± 0.13 @100ºC, ±0.14 @ 300ºC 300 to 600ºC (572 to 1112ºF) ± 0.12 ± 0.14 @300ºC, ±0.15 @ 600ºC
OM-USB-TEMP,
Maximum Error (°C) Maximum Error (°C)
(OM-USB-TEMP-AI Only)
Absolute
Range Accuracy (mV)
± 10V ± 2.78 ± 5V ± 1.40 ± 2.5V ± 0.71 ±1.25V ± 0.36
SM
3
DIGITAL I/O
Extended Warranty
Program
SM
Number of Digital I/O Channels: 8 Type: CMOS Configuration: Each DI/O bit can
be independently configured for input or output. Power on reset is input mode.
Pull-Up/Pull-Down Configuration:
All pins pulled up to +5V via 47 kresistors (default). Pull-down to ground (GND) also available.
Digital I/O Transfer Rate (Software Paced): Digital input;
50 port reads or single bit reads per second (typical), digital output; 100 port writes or single bit writes per second (typical).
Input High Voltage:
2.0V min, 5.5V absolute max
Input Low Voltage:
0.8V min, -0.5V absolute min
Output High Voltage:
0.7V max (IOL = 2.5 mA)
Output Low Voltage:
3.8V min (IOH = -2.5 mA)
COUNTER (OM-USB-TEMP-AI ONLY) Number of Channels: 1 Resolution: 32-bit Counter Type: Event counter Input Type: TTL, rising edge
triggered
Counter Read/Write Rates (Software Paced, System Dependent): 33 to 1000 read/writes
per second
Schmitt Trigger Hysteresis:
20 mV to 100 mV
Input Leakage Current:
±1.0 µA typical
Input Frequency: 1 MHz max High Pulse Width: 500 ns min Low Pulse Width: 500 ns min Input High Voltage: 4.0V min,
5.5V absolute max Input Low Voltage: 1.0V max,
-0.5V absolute min
DATA LOGGING (OM-USB-5203 ONLY) Memory Card Type: CompactFlash
(512 MB card included) Logging Rate: 1 sec up to 2 seconds (1 sec intervals) Logging Start Method: On power up, on button press or at specified date/time (user programmable) Logging Stop Method: Button press
GENERAL Power Supply Voltage (Supplied by USB Port): 4.75V min to
5.25V max
4
OM-USB-5203,
shown smaller than
OMEGACARESMextended warranty program
is available for models shown on this page.
Ask your sales representative for full details
when placing an order. OMEGACARE
covers parts, labor and equivalent loaners.
Power Supply Current (Supplied by USB Port): <100 mA typical
(USB enumeration); 270 mA typical (continuous input with all inputs configured for disabled mode)
User 5V Output Voltage Range (connected to self-powered hub):
OM-USB-TEMP/OM-USB-5203;
4.75V min to 5.25V max OM-USB-TEMP-AI; 4.9 V min to 5.1 V max
User 5V Output Current (bus powered and connected to self-powered hub):
OM-USB-TEMP/OM-USB-5203;
10 mA max
OM-USB-TEMP-AI; 5 mA max
Isolation: 500 Vdc min
SM
Device Compatibility:
USB 1.1, USB 2.0
USB Cable Length:
3 m (10') max
Dimensions:
127 L x 89 W x 36 mm H (5.0 x 3.5 x 1.4") Input Connections: Screw terminal blocks (accept 16 to 30 AWG wire) Operating Temperature: 0 to 50ºC (32 to 122ºF), 0 to 90% RH non-condensing Storage Temperature: -40 to 85ºC (-40 to 185ºF)
Weight:
OM-USB-TEMP/OM-USB-TEMP-AI:
182 g (6.4 oz)
OM-USB-5203: 227 g (8.0 oz)
actual size.
measurement system to PC USB Device Type: USB 2.0 (full-speed)
MOST POPULAR
MODELS HIGHLIGHTED!
To Order
MODEL NO. DESCRIPTION
OM-USB-TEMP 8-channel temperature input USB data
OM-USB-TEMP-AI 8-channel temperature/voltage input
32
To Order, Call or Shop Online at omega.com
OM-USB-5203 8 channel temperature input USB
SWD-TRACERDAQ-PRO TracerDAQ Pro software OM-USB-5200-ADAPTOR Spare 100/240 Vac 50/60 Hz ac adaptor
Comes complete with 2 m (6') USB cable and software and operator’s manual on CD. OM-USB-5203 also includes 100/240 Vac 50/60 Hz ac adaptor (USA plug) and 512 MB Compact Flash card.
Ordering Example: OM-USB-TEMP, 8-channel temperature input USB data acquisition module and OMEGACARESMOCW-1, 1 year extended warranty for OM-USB-TEMP adds 1 year to standard 1 year warranty).
Visit omega.com/om-usb-temp for Pricing and Details
acquisition module
USB data acquisition module
data acquisition module with data logging capability
for OM-USB-5203 (USA plug)
SM