Omega Products OM-USB-1608G User Manual

8-Channel Voltage Input High Speed USB Data Acquisition Modules
OM-USB-1608G Series
U 16-Bit High-Speed USB Devices U Acquisition Rates Ranging
From 250 kS/s to 500 kS/s
U 8 Differential (DIFF) or 16
Single-Ended (SE) Analog Inputs (Software Selectable)
U Up to 2 Analog Outputs U 8 Digital I/O Lines U Two 32-Bit Counter
Input Channels
U One Timer Output Channel
®
U TracerDAQ
Software Included for Acquiring and Displaying Data and Generating Signals
U Universal Library Includes
Support for Visual Studio
®
and Visual Studio.NET, Including Examples for Visual C++®, Visual C#®, Visual Basic®, and Visual Basic® .NET
U Comprehensive Drivers for
DASYLab
®
and NI LabVIEW™
U InstaCal Software Utility for
Installing, Calibrating, and Testing
U Supported Operating Systems:
Windows
®
XP SP2 (32-bit only)
and VISTA/7/8 (32-bit and 64-bit)
The OM-USB-1608G Series devices are low-cost, high-speed, analog and digital I/O USB devices. All of these devices offer up to eight differential (DIFF) or 16 single-ended (SE) analog inputs, up to eight digital I/O channels, two counter inputs, and one timer output.
The OM-USB-1608GX-2AO offers two, 16-bit analog output channels with DAC rates up to 500 kS/s.
Everything you need to begin acquiring, viewing, and storing data is included with each OM-USB-1608G Series device, including comprehensive software support.
Analog Model Analog Inputs Sampling Rate Outputs Digital I/O Counters
OM-USB-1608G 16 SE/8 DIFF Up to 250 kS/s 0 8 2
OM-USB-1608GX 16 SE/8 DIFF Up to 500 kS/s 0 8 2 OM-USB-1608GX-2AO 16 SE/8 DIFF Up to 500 kS/s 2 8 2
Analog Input
OM-USB-1608G Series devices provide 16-bit analog inputs that are software-selectable as 16 SE or eight DIFF inputs. These devices also support input ranges of ±10V, ±5V, ±2V, and ±1V that are software-selectable per channel
Analog Output
(OM-USB-1608GX-2AO only) The OM-USB-1608GX-2AO has two
16-bit analog outputs. Both outputs can be updated at a rate of 250 kS/s per channel; one output can be updated at a rate of 500 kS/s. The output range is fixed at ±10V. The outputs default to 0V when the host PC is shut down or suspended, or when a reset command is issued to the device.
Trigger Input
OM-USB-1608G Series devices have an external digital trigger input. The trigger mode is software-selectable for edge or level sensitive mode. You can configure edge-sensitive mode for either rising or falling edge. In level sensitive mode, you can configure for either high or low level. The default setting at power up is edge-sensitive, rising edge.
Retrigger Mode: In retrigger mode, you can set up repetitive analog input trigger events. The trigger is automatically re-armed after it is activated. Use software to set the A/D trigger count (the number of samples you want per trigger).
OM-USB-1608GX,
shown smaller than
actual size with USB
cable (included).
Eight bidirectional digital I/O connections are included with OM-USB-1608G Series devices. Each digital channel is individually configurable for input or output. The digital I/O terminals can detect the state of any TTL-level input. You can configure for pull-up (+5V) or pull­down (0V) through a jumper.
Counter Input
Each OM-USB-1608G Series device includes two 32-bit event counters for counting TTL pulses. The counters accept frequency inputs of up to 20 MHz.
Timer Output
OM-USB-1608G Series devices have a PWM timer output that can generate a pulse output with a programmable frequency in the range of 0.0149 Hz to 32 MHz. The timer output parameters are software-selectable.
External Clock I/O
OM-USB-1608G Series devices provide one external clock input and one external clock output for the analog inputs. The OM-USB-1608GX-2AO also has one external clock input and one external clock output for the analog outputs.
To Order, Call or Shop Online at omega.com
SM
1
Software
The OM-USB-1608G modules ship with an impressive array of software, including the new TracerDAQ®, a full­featured, out-of-the-box data logging, viewing, and analysis application.
Driver support and detailed example programs are included for Universal Library programming libraries for Microsoft® Visual Studio® programming languages, and other languages, including DASYLab®, and ULx for NI LabVIEW® (comprehensive library of VIs and example programs compatible with 32-bit and 64-bit LabVIEW v8.5 through 2012) and InstaCalTM installation, calibration and test utility-powerful solutions for programmers and nonprogrammers alike. These modules operate under Microsoft Windows® XP (32-bit only) and VISTA/7/8 (32-bit and 64-bit) operating systems.
The OM-USB-1608G data acquisition modules are supplied with TracerDAQ software which is a collection of four virtual instrument applications used to graphically display and store input data and generate output signals:
Strip Chart—Log and graph values
acquire from analog inputs, digital inputs, temperature inputs and counter inputs
Oscilloscope—Display values
acquired from analog inputs
Function Generator—Generate
waveforms for analog outputs
Rate Generator—Generate
waveforms for counter outputs
TracerDAQ PRO is an enhanced version of TracerDAQ and is available as a purchased upgrade (SWD-TRACERDAQ-PRO). A comparison of some of the features included in TracerDAQ vs TracerDAQ PRO is shown below.
Features Comparison
Strip Chart
TracerDAQ Strip Chart.
TracerDAQ Pro Strip Chart
with Measurements.
Feature TracerDAQ TracerDAQ Pro
Channel Types Analog input, temperature input, Analog input, temperature input, digital input, event counter digital input, event counter
Number of Channels 8 48
Number of Lanes 2 8 Maximum Samples per Channel 32,000 1 million Alarm Conditions No Yes Measurements Window No Yes Enter Annotations Software Triggering No Yes Hardware Triggering No Yes Time-of-Day Triggering No Yes Linear Scaling No Yes
No Yes
Oscilloscope
Feature TracerDAQ TracerDAQ Pro
Channel Type Analog input Analog input
Number of Channels 2 4 Measurements Window No Yes Reference Channel No Yes
Math Channel No Yes
Rate Generator
Feature TracerDAQ TracerDAQ Pro
Channel Type Counter output Counter output
Number of Channels 1 20
Function Generator
Feature TracerDAQ TracerDAQ Pro
Channel Type Analog output Analog output Number of Channels 1 16
Waveform Types Sine Sine, square, triangle, flat, pulse, ramp, random, arbitrary Duty Cycle No Yes Phase No Yes Gate Ratio No Yes Rate Multiplier No Yes Sweep (Linear and Exponential) No Yes
2
To Order, Call or Shop Online at omega.com
SM
Loading...
+ 3 hidden pages