8-Channel High Speed Voltage Input USB Data Acquisition Modules
OM-USB-1208HS,
OM-USB-1208HS-2AO,
OM-USB-1208HS-4AO
4 Differential/8 Single-Ended
Analog Voltage Inputs
13-Bit Resolution
Up to 4 Analog Outputs
16 Digital I/O
Two 32-Bit Counters
No External Power
Supply Required
The OM-USB-1208HS,
OM-USB-1208HS-2AO
and OM-USB-1208HS-4AO are
USB 2.0 full-speed voltage input
data acquisition modules (fully
compatible with both USB 1.1
and USB 2.0 ports). These are
stand-alone plug-and-play modules
which draw power from the USB
cable– no external power supply
is required. All configurable options
(including individual channel
ranges) are software
programmable, and the modules
are fully software calibrated.
All three OM-USB-1208HS modules
provide 13-bit resolution, and 4
differential or 8 single-ended analog
inputs. These modules support
software programmable ranges from
±5 to ±20V in a differential
configuration, and ±2.5 to ±10V,
and 0 to 10V in a single-ended
configuration. In software-paced
mode, these modules can sample at
a maximum of 4 kS/s. In hardwarepaced mode, they can sample at a
maximum of 1 MS/s.
The OM-USB-1208HS-2AO
provides two 12-bit analog outputs,
and the OM-USB-1208HS-4AO
provides four 12-bit analog outputs.
To Order, Callor Shop Online at omega.com
OM-USB-1208HS, shown
smaller than actual size.
Both modules offer an output range
of ±10V. Analog outputs update at a
maximum rate of 5 kS/s in softwarepaced mode; in hardware-paced
mode, each analog output updates
at a maximum rate of 1 MS/s.
On these modules, 16 digital I/O can
be programmed on each individual
bit as either inputs or outputs. Each
module supports two 32-bit TTL-level
counters that accept frequency inputs
of up to 20 MHz.
The packaging for the
OM-USB-1208HS,
OM-USB-1208HS-2AO
and OM-USB-1208HS-4AO
ensures ease of use in a variety
of applications. The modules
can easily be DIN-rail mounted
for rack applications.
The OM-USB-1208HS,
OM-USB-1208HS-2AO
and OM-USB-1208HS-4AO modules
ship with an impressive array of
software, including the new
TracerDAQ
the-box data logging, viewing, and
analysis application. Driver support
and detailed example programs are
included for Universal Library
programming libraries for Microsoft
Visual Studio®programming
languages, and other languages,
including DASYLab®, and ULx for NI
LabVIEW®(comprehensive library
®
, a full-featured, out-of-
®
of VIs and example programs
compatible with 32-bit and 64-bit
LabVIEW v8.5 through 2011) and
InstaCal
and test utility-powerful solutions for
programmers and nonprogrammers
alike. These modules operate under
Microsoft Windows®XP/VISTA/7
(32-bit and 64-bit) operating
systems.
The OM-USB-1208HS,
OM-USB-1208HS-2AO
and OM-USB-1208HS-4AO data
acquisition modules are supplied
with TracerDAQ software which
is a collection of four virtual
instrument applications used to
graphically display and store input
data and generate output signals:
TM
installation, calibration
• Strip Chart—Log and graph
values acquire from analog
inputs, digital inputs,
temperature inputs and
counter inputs
• Oscilloscope—Display values
acquired from analog inputs
• Function Generator—Generate
waveforms for analog outputs
• Rate Generator—Generate
waveforms for counter outputs
TracerDAQ PRO is an enhanced
version of TracerDAQ. A
comparison of some of the feature
included in TracerDAQ vs TracerDQ
PRO is shown on the next page.
SM
1
Page 2
TracerDAQ Strip Chart.
TracerDAQ Pro Strip Chart
with Measurements.
Features Comparison
Strip Chart
SWD-TRACERDAQ-PRO,
$220, sold separately.
OM-USB-1208HS, $499,
shown smaller than
actual size.
FeaturesTracerDAQTracerDAQ Pro
Channel TypesAnalog input, temperature input, Analog input, temperature input,
Number of Channels848
Number of Lanes28
Maximum Samples per Channel32,0001 million
Alarm ConditionsNoYes
Measurements Window NoYes
Enter AnnotationsNoYes
Software TriggeringNoYes
Hardware TriggeringNoYes
Time-of-Day TriggeringNoYes
Linear ScalingNoYes
Oscilloscope
FeaturesTracerDAQTracerDAQ Pro
Channel TypeAnalog inputAnalog input
Number of Channels24
Measurements WindowNoYes
Reference ChannelNoYes
Math ChannelNoYes
digital input, event counterdigital input, event counter
Rate Generator
FeaturesTracerDAQTracerDAQ Pro
Channel TypeCounter outputCounter output
Number of Channels120
Function Generator
FeaturesTracerDAQTracerDAQ Pro
Channel TypeAnalog outputAnalog output
Number of Channels116
Waveform TypesSineSine, square, triangle, flat, pulse, ramp, random, arbitrary
Duty CycleNoYes
PhaseNoYes
Gate RatioNoYes
Rate MultiplierNoYes
Sweep (Linear and Exponential)NoYes
2
To Order, Callor Shop Online at omega.com
SM
Page 3
DC Voltage Analog Input Ranges
and Absolute Accuracy
(Differential Mode)
VoltageAbsolute
RangeAccuracy (LSB)
±20V±9.55 typ, ± 13.18 max
±10V±4.59 typ, ± 6.23 max
±5V±2.25 typ, ± 2.75max
Power Up and Reset State: 0V
Output Noise: 0.53 mV rms
Absolute Accuracy: ±0.1%
Slew Rate: 6.7V/µs typ
DIGITAL I/O
Digital Type: CMOS
Number of I/O: 16
Configuration: Each bit may be
configured as input (power on
default) or output
Pull-Up Configuration: The port
has 47 kΩ resistors configurable as
pull-ups or pull-downs by an internal
jumper (default setting is pull-down)
Digital I/O Transfer Rate
(System Paced): 33 to 8000 port
reads/writes or single-bit
reads/writes per second typ,
system dependent.
Input High Voltage: 2.0V min,
5.5V absolute max
Input Low Voltage: 0.8V max,
-0.5V absolute min, 0V
recommended min
Output High Voltage: 4.4V min
(IOH = -50 µA), 3.76V min
(IOH = -24 mA)
Output Low Voltage: 0.1V max
(IOL = 50 µA), 0.44V max
(IOL = 24 mA)
Output Current: ±24 mA max per
terminal
Output Low Voltage:
ANALOG OUTPUT
D/A Converter: DAC7553
Number of Channels:
configurable for edge- or levelsensitive, rising or falling edge,
high or low level. Power on default
is edge sensitive, rising edge.
Trigger Latency: 1 µs + 1 clock
cycle max
Comes complete with 2 m (6') USB cable, Quick Start Guide and software and operator’s manual on CD.
Ordering Example: OM-USB-1208HS high speed multifunction USB data acquisition module with eight 13-bit 1 MS/s analog inputs and
OCW-1 OMEGACARESM1 year extended warranty (adds 1 year to standard 1 year warranty).
4
OM-USB-1208HS, shown
Supply Current: Total current
smaller than actual size.
consumption including 5V, and
digital output and analog output
currents
Suspend Mode: <2.5 mA
Enumeration: <100 mA
Run Mode: <500 mA
Power Consumption Excluding
Analog and Digital Outputs
Run Mode: 1.175 W max
(235 mA input current)
Power Available for 5V, AICKO,
AOCKO, TMR, Analog Outputs,
Digital I/O:
Run Mode: 1.325 W max
+5 V Output Voltage Range:
Run Mode: 4.5V min, 5.25V max
Suspend Mode, Enumeration:
0V
GENERAL
Operating Temperature
Range: 0 to 50°C (32 to 122°F)
Storage Temperature
Range: -40 to 85°C (-40 to 185°F)
Humidity: 0 to 90% RH
non-condensing
Communications:
USB 2.0 (high-speed)
Acquisition Data Buffer: 4 kS
Signal I/O Connector: 2 banks
of screw-terminal blocks
Dimensions:
127 L x 89.9 W x 35.6 mm H
(5.00 x 3.53 x 1.40")
Weight: 160 g (5.6 oz)
+5V Output Current (Run Mode,
No Other Output Loads):
265 mA max (1.325 W)
USB SPECIFICATIONS
USB Device Type: USB 2.0
(high-speed)
USB Device Compatibility:
USB 1.1, 2.0
USB Cable Length: 5 m
OMEGACARE
available for models shown on this page. Ask
your sales representative for full details when
placing an order. OMEGACARE
labor and equivalent loaners.
SM
extended warranty program is
(16.4') max
MOST POPULAR MODELS HIGHLIGHTED!
To Order Visit omega.com/om-usb-1208hs_series.com for pricing and details
Model No.Description
OM-USB-1208HSHigh speed multifunction USB data acquisition module with eight 13-bit
OM-USB-1208HS-2AO1 high speed multifunction USB data acquisition module with eight 13-bit
OM-USB-1208HS-4AOHigh speed multifunction USB data acquisition module with eight 13-bit
SWD-TRACERDAQ-PROTracerDAQ Pro software
To Order, Callor Shop Online at omega.com
1 MS/s analog inputs
1 MS/s analog inputs and two 12-bit 1 MS/s analog outputs
1 MS/s analog inputs and four 12-bit 1 MS/s analog outputs