NOMAD
TM
Datalogger
Features
•
16,192 records
•
Record length from 4 hrs 29 min to over 2 years
•
Nonvolatile EEPROM memory for record
keeping
•
Over 2 years operation on replaceable battery
•
4 different launch modes
•
Average, minimum or maximum recording
•
Single or Wrap-around recording
•
PC compatible
•
External RTD sensor for temperature
dataloggers
•
Windows user friendly OMEGA
®
Software to view
plots, make prints, and export data for use in
other programs
•
Weighs only 2 ounces with battery
Setup the NOMADTMDATALOGGER
NOTE: Close all programs before launching the
NOMAD Datalogger.
Attach the NOMAD to an available Serial port of
your computer using your RS-232 cable
purchased with your unit (see ordering block).
If you wish to use the external RTD sensor with
Temp dataloggers only, plug it in to the “Temp
Probe” socket on the NOMAD.
From the Windows program manager select the
NOMAD icon and start the program. The NOMAD
Datalogger main menu screen will appear.
Choose “COM port” from the “Setup” menu to
set and test serial communication with the
datalogger.
NNOO TTEE::
If NOMAD is not connected, an error message
“Port is available, but no NOMAD was detected” will be
displayed. Check cable connections and COM port settings
on your computer. Select “Setup” again to test
communication. If you still get an error message, choose an
alternate COM port setting.
Once successful, you will be greeted by the
“NOMAD Launch Utility” screen.
Follow your application requirements in choosing
the appropriate menu item, using on-line help as
needed.
Ordering Information
To place an order from the USA or Canada call: 1-800-TC-OMEGA
®
NOMADTMQuick Start
Installing “NOMAD” software:
Verify your computer clock is set to correct time,
and date since NOMAD obtains its time stamp
from your computer.
Before installation, make sure all other
Windows programs have been closed.
Having open programs may conflict with the
installation process, causing the computer to
lock-up. If this occurs, you will need to
reboot your computer.
W
indows 95 and above: Insert this CD into your
CD-ROM drive, open your favorite browser and go
to the file menu, select “open File...” go to the CD
and Selet the file: “Setup.exe” (or Nomad24.exe).
Follow the directions on the screen to complete
installation. The installation will make a program
group called NOMAD. Click on this icon , to
start the NOMAD software.
NOTE: Please review the on-line user manual for a
complete description of all features. This is a text file
included on the installation disk. File Name: manual.txt
NOMADTMLogger Specifications
Temperature:
Operating range with internal sensor:
0 to 50°C (32 to 122°F)
Measurement range with external sensor:
-40 to 90°C (-40 to 194°F)
Accuracy: ±1.8°C using internal sensor
Electronics temperature coefficient of error using
external sensor ±.025% Full Scale/°C
Resolution better than 0.9°C:
Sensor 1 K ohm, RTD alpha = 3750
Humidity:
Measurement range:
20 to 90% non-condensing
Operating temperature range: 0-50°C
Measurement accuracy: ± 5% RH @25°C
±0.3%RH/°C away from 25°C
Sensor: Bulk polymer resistive
RH response: 63% of step change in less than
5 minutes
Measurement Interval:
Programmable: from 1 second to 3 hours
EEPROM memory size: 16K data samples
Battery: one 3.6 volt AA Lithium Cell operating
for more than 2 years
Note: This is not a standard battery.
Slide to Open
Battery Compartment
Dimensions:
Length: 2.80" [71.1mm]
Width: 2.20" [55.9mm]
Depth: 0.96" [24.4mm]
This device is marked with the international hazard symbol. It is important to read
the Setup Guide before installing or commissioning this device as it contains
important information relating to safety and EMC.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace
period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures
that OMEGA’s customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon
examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s
WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to
mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized
modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows
evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper
specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components
which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to of fer suggestions on the use of its various products. However, OMEGA
neither assumes responsibility for any omissions or er rors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA war rants only that the parts manufactur ed by it will
be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of pur chaser set forth herein are exclusive and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for consequential,
incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity,
medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in
our basic WARRANTY/ DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold
OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a
manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR W
ARRANTY RETURNS, please have the
following information available BEFORE contacting
OMEGA:
1. P.O. number under which the product
was PURCHASED,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult
OMEGA for current repair charges. Have the
following information available BEFORE contacting
OMEGA:
1. P.O. number to cover the COST
of the repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific
problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the
latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced,
translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of
OMEGA ENGINEERING, INC.
M2510/1003
TRADEMARK NOTICE: , omega.com
®
, and NOMAD
TM
are trademarks of OMEGA
Engineering, Inc.
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply.
OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the
CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for
any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
NOMAD
™
Datalogger
OM-NOMAD-T
OM-NOMAD-RH
www.omega.com
e-mail: info@omega.com
User ’s Guide
Shop on line at
Serial #
Label
located
under
cover
MODEL # DESCRIPTION
OM-NOMAD-T-16 Temperature datalogger 16K memory
(16,192 samples)
OM-NOMAD-RH-32 Temp/RH datalogger 32K memory
(16,192 samples).
OM-NOMAD-RTD External temp. sensor with 6ft cable
NOTE: Not useable with OM-NOMAD-RH models
OM-NOMAD-CP9 RS-232 cable for IBM PC, 9 pin female D-sub.
connector
OM-NOMAD-CP25 RS-232 cable for IBM PC, 25 pin female D-sub.
connector
OM-NOMAD-WIN Windows software, CD-ROM
OM-NOMAD-BATT Replacement 3.6V Lithium battery
This is not a
standard AA
battery.
®
e-mail: sales@omega.co.uk
Toll Free in England: 0800 488 488
TEL: +44 161 777 6611 FAX: +44 161 777 6622
Northbank, Irlam Manchester M44 5BD United Kingdom
ISO 9002 Certified River Bend Technology Centre
United Kingdom: One Omega Drive
e-mail: info@omega.de
Toll Free in Germany: 0800 639 7678
TEL: +49 7056 9398-0 FAX: +49 7056 9398-29
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
e-mail: sales@omega.fr
Servicing Europe:
FAX: (001) 203-359-7807
®
®
®
®
info@omega.com
Internet e-mail
®
®
ñol: (001) 203-359-7803
Servicing North America:
On-Line Service
®
Toll Free in France: 0800 466 342
TEL: +33 1 61 37 29 00 FAX: +33 1 30 57 54 27
France: 11, rue Jacques Cartier, 78280 Guyancourt
e-mail: info@omegashop.cz
TEL: +420 59 6311899 FAX: +420 59 6311114
Czech Republic: Frystatska 184, 733 01 Karviná
e-mail: sales@omegaeng.nl
Toll Free in Benelux: 0800 0993344
TEL: +31 20 3472121 FAX: +31 20 6434643
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
e-mail: espanol@omega.com
Latin American: En Espa
Mexico and TEL: (001)800-TC-OMEGA
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
Customer Service: 1-800-622-2378 / 1-800-622-BEST
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
For immediate technical or application assistance:
e-mail: info@omega.ca
TEL: (514) 856-6928 FAX: (514) 856-6886
Laval (Quebec) H7L 5A1
Canada: 976 Bergar
e-mail: info@omega.com
TEL: (203) 359-1660 FAX: (203) 359-7700
ISO 9001 Certified Stamford CT 06907-0047
USA: One Omega Drive, P.O. Box 4047
www.omega.com
OMEGAnet
Select popular
pre-defined data
formats for
applications.
Use Export
data
summary from
the View menu
for detailed
information
about the
export format.
Custom allows
user to specify
time format and
field separators.
Accept chosen
parameters.
Abort selection
process.
On-line help
available.
Select information to export, temperature
and humidity counts are used primarily as
diagnostic tool.
Export Setup
Launching the NOMAD
TM
DATALOGGER
From NOMAD Datalogger
menu select Setup, submenu Readout.
After data download the
attached NOMAD information
will appear.
Alternately from File select
Open to view a previously
saved data file. One file at a time.
The Y axis automatically scaled for
maximum resolution based upon
max and min data records.
Temperature shown on left in
segmented red while RH is shown
on the right in continuous blue line.
Recording start date and time
stamp along the X axis with serial
number and units of sampling
interval selected.
NOMAD application description.
User entered at time of launch.
Zoom in on any
selected plot.
Using the mouse,
click and drag
draw box around
area of interest.
Multiple zooms
are allowed.
Plots can be
copied and
imported into
applications
running under
Windows.
Readout and Plotting
Shutdown any unnecessary programs before launching the
NOMAD Data Logger, especially programs that would be
busy processing data (and using much CPU time).
Otherwise, the NOMAD Data Logger may not launch
properly.
Run the NOMAD Launch Utility. Change the CommPort
number if necessary. The Comm Port setting will be stored
and then retrieved upon subsequent executions of the
NOMAD Launch Utility.
After successfully completing a communication test the
NOMAD datalogger can be launched. Choose "Configure &
Launch Datalogger" from the "Logger" menu. The program
establishes a serial link with the NOMAD and opens the
"Launch the Datalogger" dialog window.
You can enter up to 48 characters of arbitrary descriptive
text to the "Memo or Description" entry box. This text is
saved in the NOMAD memory during the launching process
and then retrieved along with the recorded data during the
readout process.
There are 4 different ways to start data recording.
1. Now.
2. At time specified below.
3. When button on datalogger is pressed.
4. After delay starting when button is pressed.
There are 2 different data recording options when the
NOMAD memory is full. The NOMAD may either stop
recording data or it may start overwriting the oldest data. In
addition, The datalogger stops recording when it is
connected to the computer, and the computer begins data
readout or tries to launch the NOMAD again. In the latter
case, new data starts filling the memory from the beginning,
overwriting the previous record.
By pressing the "Sampling Option" pushbutton you can
choose to record maximum, minimum, average, or one
sample every interval. If maximum, minimum, or average is
chosen, the datalogger takes 4 samples over the interval
and uses these 4 points for the maximum, minimum, or
average calculation. The "Sampling Interval" pushbutton
allows you to select the interval at which the data is
recorded. The highest sampling rate available internally is 1
sample per second. This means that the minimum sampling
interval is 1 second for sampling option set to "single", and
4 seconds for the other sample options. If you select a
sampling interval of less then 4 seconds, and then select a
sampling option of minimum, maximum or average, the
program will automatically adjust the sampling interval to 4
seconds. The displayed total record length indicates the
recording time available until the NOMAD memory is full.
This number depends on the memory size and sampling
interval.
The displayed NOMAD Version Number is a firmware
version number which allows you to distinguish between
subsequent versions of the datalogger. Sample capacity
indicates the amount of memory available. The system time
is the computer current time. The NOMAD automatically
sets its clock by reading the time from the computer. If the
computer time is incorrect, use the appropriate Windows
commands to set the computer clock.
Launching NOMAD
Recording starts
immediately upon
Launch command.
Recording starts at time
set in entry box.
Recording starts after
“Run” button is pressed
on Datalogger.
Recording starts, following
a user specified delay
time set in the entry box,
after “Run” button is
pressed.
Delayed Data Collection
entry box.
Sampling option, selects
single recording or the
highest, lowest or average
of 4 samples.
Sampling interval in
seconds, minutes or hours
may be specified.
Automatically calculated
from interval entry and
device capacity.
User entry Describe the
NOMAD application, will
appear on print plot.
(48 characters max.)
Stop sampling when
memory is full.
Continuous recording most
recent data available.
Selects the Serial Port
NOMAD Serial # Factory
Assigned.
Current time stamp based
on host computer’s internal
clock setting.
Relative Humidity Alarm
20 to 70% allowed.
Temperature Alarm
user specified limits in
degrees F or C.
Pressing “RUN” button
while recording will indicate
alarm excursions on the
NOMAD Led.
Start Sampling Abort Launch