Omega Products OM-MT20 Installation Manual

User’s Guide
http://www.omega.com
e-mail: info@omega.com
OM-MT20
Operator’s Manual
OMEGAnet® On-Line Service Internet e-mail http://www.omega.com info@omega.com
Servicing North America:
USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047
Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM
Customer Service: 1-800-622-2378 / 1-800-622-BESTSM Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSM
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico and Latin America: Tel: (95) 800-826-6342 FAX: (95) 203-359-7807
En Español: (95) 203-359-7803 e-mail: espanol@omega.com
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: (31) 20 6418405 FAX: (31) 20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: nl@omega.com Czech Republic: ul. Rude armady 1868, 733 01 Karvina-Hranice
Tel: 420 (69) 6311899 FAX: 420 (69) 6311114
Toll Free: 0800-1-66342 e-mail: czech@omega.com France: 9, rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400 FAX: (33) 130-699-120
Toll Free in France: 0800-4-06342
e-mail: france@omega.com Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: 49 (07056) 3017 FAX: 49 (07056) 8540
Toll Free in Germany: 0130 11 21 66
e-mail: info@omega.de United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5EX, England
Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622
Toll Free in the United Kingdom: 0800-488-488
e-mail: info@omega.co.uk
OM-MT20 Manual, Page i
M3532 / 0300
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
OM-MT20 Manual, Page ii
Table of Contents
Introduction Page 1
What’s In This Package Safety Precautions Palm OS Handheld Computer Compatibility
Hardware Page 2 - 5
Getting Started Thermocouple Sensors Batteries Specifications Regulatory Compliance Calibration Certification of Accuracy
Software Page 6 - 7
Specifications Software Installation
OmegaWare AL Software Page 8 - 11
Getting Started Running a Test Viewing Data Details OmegaWare AL Options About OmegaWare AL HotSync and Data Uploads Restoring the OmegaWare AL Application
OmegaWare SE Software Page 12 - 14
Getting Started Collecting Temperature Data Viewing and Clearing Saved Data OmegaWare SE Options About OmegaWare SE HotSync and Data Uploads Restoring the OmegaWare SE Application
Contacting Omega Page 15 Software License Agreement Page 16 Warranty/Disclaimer Page 17 Return Requests / Inquiries Page 18 Copyright Information Page 19
OM-MT20 Manual, Page iii
INTRODUCTION
Congratulations on your purchase of the Omega OM-MT20 Temperature Acquisition Module for Palm OS (Operating System) handheld computers!
The OM-MT20 Temperature Acquisition Module enables you to measure and record temperature values right on your Palm OS handheld computer, and organize your data to turn it into useful information.
This manual will describe the features of the hardware to help you get the most out of your OM-MT20. Consult the OM-MT20 software section of this manual and the documentation that came with your Palm OS
handheld computer if you are not familiar with the operation of these components.
What’s In This Package
Your OM-MT20 Temperature Acquisition Module comes complete with the following components:
1 OM-MT20 Temperature Acquisition Module
2 AAA batteries
1 OM-MT20 Manual
1 OM-MT20 Software CD-ROM
If any of these components are missing please contact Omega Engineering.
Safety Precautions
Your OM-MT20 Temperature Acquisition Module is a precision electronic device. As with any such electronic device, care should always be exercised in its proper use.
Do not, under any circumstances, attempt to measure temperatures on energized electrical components or inside electrical or electronic enclosures.
The wires in thermocouple sensors carry electrical signals and power and should not be exposed to any environment where they could cause harm.
Never plug anything into the OM-MT20 module inputs except type J, K ,T, or E thermocouples. If you are unsure about thermocouple compatibility please consult Omega Engineering.
Do not drop your OM-MT20 module. Do not store your OM-MT20 module in direct sunlight or near a source of heat or cold outside of the
operating limits of the module (refer to the specifications included in this manual). Always keep your OM-MT20 module dry. Do not immerse your OM-MT20 module in water. Never open the OM-MT20 module case. There are no user modifiable or serviceable parts, adjustments, or
mechanisms contained in the case. If you are having any problem with the operation of your module please contact Omega Engineering.
Palm OS Handheld Computer Compatibility
The OM-MT20 Temperature Acquisition Module is compatible with handheld computers running either Palm OS version 2.x or Palm OS 3.x. These include the following handheld computers:
Palm Pilot SE, Palm Pilot Professional, Palm III series, Palm VII.
IBM WorkPad
Symbol Technologies SPT 1500
Check the Omega website for information regarding compatibility with other handheld computers as they become available.
OM-MT20 Manual, Page 1
HARDWARE
Getting Started
The OM-MT20 Temperature Acquisition Module is very easy to use. To get started as quickly as possible follow these simple steps.
Install two AAA batteries to power up your OM-MT20 Module.
Install the Palm Desktop version 2.x or 3.x onto your PC, HotSync your Palm to your desktop, and run
the setup.exe program included on the OM-MT20 OmegaWare software CD-ROM.
Consult the OM-MT20 manual and the documentation that came with your Palm OS handheld computer if you are not familiar with the operation of these components.
Clip the OM-MT20 onto the HotSync / serial port located on the bottom of your Palm OS handheld computer,
Plug one or two thermocouple probes with miniature connectors into the inputs located on the bottom of your OM-MT20 module.
Launch your preferred OM-MT20 application software to collect and manage your temperature information.
Use the HotSync capabilities of the Palm OS handheld computer to upload your collected temperature data to your personal computer desktop.
Thermocouple Sensors
Thermocouple Types and Configurations
The OM-MT20 is designed to operate with type J, K, T, and E thermocouples with industry standard miniature connectors.
Thermocouple sensors are available in a wide range of configurations from various suppliers. These configurations range from very small beaded thermocouples with minimal thermal mass to heavy-duty penetration probes. Please contact Omega Engineering if you have any difficulty locating a sensor suited to your application.
Installing Sensors
The industry standard miniature connectors on the thermocouple have a wide blade and a narrow blade. Insert the connector in the channel 1 or channel 2 input on the OM-MT20 with the narrow blade (sometimes marked with a “+”) on the right.
The lower input port of the OM-MT20 is configured as channel 1. The upper input port of the OM-MT20 is configured as channel 2.
Batteries
Battery Installation
Remove the battery cover by gripping the ribs at the right front and left front corners of the OM-MT20 case between your thumb and forefinger. Holding the case in one hand and the battery cover in the other, slide the cover forward without lifting to expose the battery compartment.
Place two standard AAA alkaline cells in the battery compartment in the orientation indicated by the markings in the compartment and replace the cover.
Battery Life
A new set of batteries in the OM-MT20 will last approximately 100 hours while taking temperatures every second.
OM-MT20 Manual, Page 2
The OM-MT20 module is inactive when it is not taking temperatures or communicating with the Palm OS handheld computer. Significant power savings can be realized by increasing the interval between temperature readings. For example, when data logging every ten seconds, a new set of batteries should last for approximately 1000 hours.
Actual battery life will depend on how you use your OM-MT20 Temperature module.
If you use any power source other than AAA alkaline batteries to power your OM-MT20 module you will cause damage to the module.
OM-MT20 Manual, Page 3
Specifications
Inputs 1 or 2 External Thermocouples Internal Temperature (Thermistor) Internal Battery Voltage
Supported Temperature Sensors Thermocouple Types J, K, T, E Uses industry standard miniature connectors
The thermocouple leads must be less than 3 meters in length.
Units Degrees F or C
Temperature Measuring Range
-328°F (-200°C) to +1832°F (+1000°C) for Type J
-328°F (-200°C) to +1832°F (+1000°C) for Type K
-328°F (-200°C) to +734°F (+390°C) for Type T
-328°F (-200°C) to +1814°F (+990°C) for Type E
Resolution .1 degree for all temperatures in range
Accuracy ±1.8°F (±1°C) ±0.1% of Reading
When subjected to a field strength of at least 3V/m over a frequency range of 27-500 MHz in accordance with BS EN50082-1, the unit exhibited no more than +/-3°C error.
Data Storage 10,000+ readings for SE and AL with 300K free memory on your Palm
Logging Interval 1 second to 49 hours
Power 2 AAA alkaline batteries provide 100 hours of continuous operation
Operating Temperature Range 32°F (0°C) to +122°F (50°C)
Dimensions (Versid Module Only)
3.2 x 2.6 x 0.875 inches (8.13 x 6.60 x 2.22 cm)
Weight, with Batteries
2.8 ounces (79.4 grams)
OM-MT20 Manual, Page 4
Loading...
+ 16 hidden pages