Portable Data Loggers with USB Interface
OM-EL-USB Series
U Temperature, Temperature/RH/
Dew Point, Voltage, and
Current Models
U Data Logger Plugs Directly into
Computer’s USB Port for Easy
Setup and Data Download (No
USB Cable Required)
U User-Programmable Alarm
Thresholds with LED
Indicators
U Bright Red, Green, and
Orange LED Indication
U Low-Battery Warning
U IP67 Protection
The OM-EL-USB Series of data
loggers includes models for
temperature, temperature/relative
humidity, voltage, and current
measurement. The user can easily
set up the data logger and download
the stored data by plugging the
module into a PC’s USB port and
running the easy-to-use Windows
software. Software-selectable setup
parameters include logging rate,
start time, high/low alarm settings,
and temperature units (°C or °F).
Data can then be graphed, printed,
and exported to other applications
such as Excel. Each data logger
is supplied complete with a long-
life lithium battery. Built-in LED
indicators show data logger status.
OM-EL-USB Series data loggers are
protected against moisture to IP67
standards when the protective cap
is fitted.
Specifications
OM-EL-USB-1 TEMPERATURE
DATA LOGGER
Range: -35 to 80°C (-31 to 176°F)
Resolution: 0.5°C (1°F)
Accuracy: ±1.0°C (±2.0°F)
Memory: 16,000 temperature
readings
Logging Interval: 10 sec to 12 h
Operating Temperature
Range: -35 to 80°C (-31 to 176°F)
Alarm Thresholds:
High/low alarm thresholds
selectable in software
Start Date/Time:
Selectable in software
Status Indicators (LEDs):
Red, green and orange
OM-EL-USB-1
Dimensions: mm (inch)
27 (1.06)
20.5 (0.81)
94 (3.70)
OM-EL-USB-CASE, protective
metal case for OM-EL-USB-1
and OM-EL-USB-2 data loggers.
Software: Windows 2000/XP/Vista/7
(32- and 64-bit)
Power: 1⁄2 “AA” 3.6 V lithium
battery (included)
Battery Life: 1 year (at 25°C
and 1 minute logging interval)
Weight: 43 g (1.5 oz)
Dimensions: See dimensional drawing
Windows software—alarm setup window
End view
OM-EL-USB-1, shown
smaller than actual size
Windows software—initial setup window
Windows software—logger start window
To Order, Call or Shop Online at omega.com
SM
1
OM-EL-USB-2
26.4 (1.04)
103 (4.06)
OM-EL-USB-3
26.9 (1.05)
OM-EL-USB-4
112 (4.40)
OM-EL-USB-2
Dimensions: mm (in)
OM-EL-USB-2
AND OM-EL-USB-2-PLUS
(TEMPERATURE AND RELATIVE
HUMIDITY) (DEW POINT
INDICATION VIA WINDOWS
SOFTWARE)
TEMPERATURE
Range: -35 to 80°C (-31 to 176°F)
Resolution: 0.5°C (1°F)
Accuracy:
OM-EL-USB-2: ±0.5°C (±1.0°F);
OM-EL-USB-2-PLUS:
±0.3°C (±0.6°F)
HUMIDITY
Range: 0 to 100% RH
Resolution: 0.5% RH
Accuracy (20 to 80% RH):
OM-EL-USB-2: ±3% RH;
OM-EL-USB-2-PLUS:
±2.0% RH
DEW POINT
Accuracy (overall error in the
calculated dew point for RH
measurements from 40 to 100%
RH @ 25°C): ±2°C (±4°F)
Memory: 16,000 temperature and
16,000 relative humidity readings
Logging Interval:
10 seconds to 12 hours
Operating Temperature Range:
-35 to 80°C (-31 to 176°F)
Alarm Thresholds: High/low
alarm thresholds for % RH and
temperature, selectable in software
Start Date/Time:
Selectable in software
Status Indicators (LEDs):
Red and green
Software: Widows 2000/XP/VISTA/7
(32-bit and 64-bit)
Power: 1⁄2 “AA” 3.6 V lithium battery
(included)
Battery Life: 1 year typical (depends
on sample rate, ambient temperaure
and use of alarm LEDs)
Weight: 57 g (2 oz)
Dimensions: See dimensional drawing
OM-EL-USB-3, -4
Dimensions: mm (in)
OM-EL-USB-3 VOLTAGE
Range: 0 to 30 Vdc
Resolution: 100 mV
Accuracy: ±1%
Memory: 32,000 voltage readings
Logging Interval:
1 second to 12 hours
Input Connection:
Screw terminals
Operating Temperature Range:
-25 to 80°C (-13 to 176°F)
Alarm Thresholds: High/low alarm
thresholds selectable in software
Start Date/Time:
Selectable in software
Status Indicators (LEDs):
Red and green
Power:
1
⁄2 “AA” 3.6 V lithium
battery (included)
Battery Life: 1 year typical
(depends on sample rate,
ambient temperature and use
of alarm LEDs)
Weight: 57 g (2 oz)
Dimensions:
See dimensional drawing
OM-EL-USB-4 CURRENT
Range: 4 to 20 mA
Resolution: 0.1 mA
Accuracy: ±1%
Memory: 32,000 current readings
Logging Interval:
1 second to 12 hours
Input Connection: Screw terminals
Operating Temperature Range:
-35 to 80°C (-31 to 176°F)
Alarm Thresholds: High/low alarm
thresholds selectable in software
Start Date/Time: Selectable
in software
Status Indicators (LEDs):
Red and green
Power:
1
⁄2 “AA” 3.6 V lithium
battery (included)
Battery Life: 1 year typical
(depends on sample rate,
ambient temperature and use
of alarm LEDs)
Weight: 57 g (2 oz)
Dimensions:
See dimensional drawing
To Order Visit omega.com/om-el-usb-1 for Pricing and Details
Model No. Description
OM-EL-USB-1 Temperature data logger with USB interface
OM-EL-USB-2 Temperature/RH/dew point data logger with USB interface
OM-EL-USB-2-PLUS High accuracy temperature/RH/dew point data logger with
OM-EL-USB-3 Voltage data logger with USB interface
OM-EL-USB-4 Current data logger with USB interface
OM-EL-BATT Replacement 3.6 V lithium battery
OM-EL-USB-CASE Waterproof case NEMA 4X (IP67) for OM-EL-USB-1 and
Each data logger is supplied with Windows software on CD-ROM, operator’s manual
and 3.6 V lithium battery. Data logger plugs directly into computer’s USB port
(no USB cable required). OM-EL-USB-2 temperature/RH/dew point data logger is limited to
temperature measurement only when used inside the OM-EL-USB-CASE.
Ordering Example: OM-EL-USB-1, temperature data logger with USB interface.
USB interface
OM-EL-USB-2 data loggers
2
To Order, Call or Shop Online at omega.com