PANEL MOUNT INFRARED COMMUNICATIONS MODULE
INSTRUCTION
SHEET
M-3147
The OM-EL-PANEL-IR moduleconverts serial data between electrical and InfraRed formats. Idealfor applications that require remote control or dangerous
environments where cables would be a safety risk, OM-EL-PANEL-IR employs the IrDA infra-red communications standard to achieve reliable transfer of
data. The snap-inintegral bezel makes installation quickand easy.
Panel mounted
Uses IrDA Communication Standard
Connects to Microcontroller, UART,
or EasyLog Module
Half-duplex Communications
10-Way Pin Header
Baud rate
Select the baudrateas shown inthe table below. Wherea "0"
is shown, either connect the pin to 0V or leave it
unconnected. Where a"1" is shown, connectthe pinto V+.
Pin6 Pin7 Pin8 Baud
0 0 0 9600
0 0 1 14400
0 1 0 19200
0 1 1 28800
1 0 0 38400
1 0 1 57600
1 1 0 115200
InfraRed Module OM-EL-PANEL-IR
Specification Min Typ Max Unit
Power supply 3 5 5.5 V
Current consumption Receive 3 5 6 mA
Transmit 7 12 25 mA
Communication cone ±15 °
Communication distance 0 1/3.3 m/ft
Data rate ( ) 9600 115200 bps
Infra-red pulse duration 1.6 s
Latency 10 ms
Note 1: Depending on transmission duty cycle
Note 2: Under normal lighting conditions
Note 3: This is the time delay between receive and transmit operations
bits per second
3
1
2
Model No
µ
DIMENSIONS All dimensions in mm (inches)
20.0 (0.79)
12.7 (0.50)
17.5 (0.69)
40.0 (1.57)
27.3 (1.07)
e
fg
5
3
2
4
1
37.5 (1.78)
6
10
9
8
7
abcd
h
a. 2.00 (0.08)
b. 6.00 (0.24)
c. 1.60 (0.06) max
d. 6.00 (0.24)
e. 2.54 (0.10)
f. 0.50 (0.02)
g. 6.00 (0.23)
h. 2.00 (0.08)
Pin Name
1. Polarity
2. Disable
3. N/C
4. 0V
5. V+
6. Baud 3
7. Baud 2
8. Baud 1
9. RxD
10. TxD
Panel cut-out
38.0 x 18.0 (1.50 x 0.71)
Panel thickness
1.0 to 2.5 (0.04 to 0.1)
PANELFITTING
Locate the module by passing it through the front of the panel cut-out and gently push until the rear of the bezel is flush with the panel.
DO NOT PUSH ON THE SCREEN. The snap-in lugs will now automatically hold the module firmly in position.
PIN FUNCTION
1. Polarity Selects whether the transmit/receivelines usepositive ornegative logic.
2. Disable Disablesthe receiver/transmitter. Connect to0V todisable.
3. N/C Noconnection. Do not connectanything tothis pin.
4. 0V 0V Powersupply.
5. V+ 5V Powersupply.
6. Baud3
7. Baud2 Baud rate select (seetable overleaf).
8. Baud1
9. RxD Receive data - receiveddataappears on this pin.
10. TxD Transmitdata -apply datatobe transmitted to this pin.
Connect to 0V forpositive logic. Connect toV+ orleave unconnectedfornegative logic.
Connect to V+ orleave unconnectedto enable.
If the PANEL-IRis solely used for receivingdata thenTxD shouldbeconnected to V+ viaa 47kresistor.
APPLICATIONNOTES
Communication can take place atdistances from0m(i.e. "nose-to-nose") to1m. Theredwindow of the OM-EL-PANEL-IR module should bepointed atthe
window of the device atthe other endof the InfraRedlink. The InfraRed light beamspans approximately 30°,so the twodevices do nothave tobe directly
aligned. Thereshould however be a clear line of sight between the twodevices. At closerange, communicationis more forgiving and small obstacles will
not affect the link.
1m (3.3ft)
1m (3.3ft)
30°
OM-EL-PANEL-IR
OM-EL-PANEL-IR
OM-EL-PANEL-IR
Protocol
The OM-EL-PANEL-IR module acts as a "transparent" data translator i.e.: there is no built-in communications protocol to adhere to. The deviceworks by
transmitting anIR pulse for "Low" bits,and not transmitting anything for"High" bits.Since the first bit ofthe serialbyte (the start bit) isalways "Low", this
marks the start of thebyte. Subsequent bits are synchronized from there. Take care to set the Polarity pin (pin 1) correctly. For more detailed application
advice, contact OMEGA.
Connection to EasyLog Data Logging Modules
Connect as shown below to give your OM-EL-1 InfraRed communication capability. The flying leads should be soldered into the two PCB holes on the
OM-EL-1 module,at the lefthand end of the10-way pin header. A1K resistor mustbe fitted asshown if aserial communication cableis used inaddition to
the InfraRed link, otherwiseit canbeomitted.
10
TxD
RxD
5V
0V
OM-EL-PANEL-IR
V+
1K
1
+
LITHIUM
BATTERY
OM-EL-1
-
V-
Typical application: industrial controller
The OM-EL-PANEL-IRmoduleforms part of anInfraRed communicationslink betweentwo totallyisolatedsystems.
The OM-EL-PANEL-IRmodulewillcommunicate with any computer featuringan IrDAcompatible serialport, orany otherPCfittedwith a OM-EL-LINK-IR adapter.
Microcontroller
OMEGAnet On-Line Service
http://www.omega.com
USA:
ISO 9001 Certified
Canada:
For immediate technical or application assistance:
USA and Canada:
Mexico and
Latin America:
Benelux:
Czech Republic:
France:
Germany/Austria:
United Kingdom:
ISO 9002 Certified
OM-EL-PANEL-IR
1
UART
omega.com
SM
RxD
TxD
10
TM
®
Internet e-mail
@
info omega.com
Servicing North America:
One Omega Drive, Box 4047
Stamford, CT 06907-0047
Tel: (203) 359-1660 FAX: (203) 359-7700
@
e-mail: info omega.com
976 Bergar
Laval (Quebec) H7L 5A1
Tel: (514) 856-6928 FAX: (514) 856-6886
e-mail: canada omega.com
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Tel: (95) 800-TC-OMEGA FAX: (95) 203-359-7807
En Español: (203) 359-1660 ext:2203 e-mail:
@
SM
SM
SM
SM
espanol omega.com
@
Servicing Europe:
Postbus 8034, 1180 LAAmstelveen, The Netherlands
Tel: (31) 20 6418405 FAX: (31) 20 6434643
Toll Free in Benelux: 06 0993344
@
e-mail: nl omega.com
Ostravska 767, 733 01 Karvina
Tel: 42 (69) 6311899 FAX: 42 (69) 6311114
e-mail: czech omega.com
9, rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400 FAX:(33) 130-699-120
Toll Free in France: 0800-4-06342
e-mail: france omega.com
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: 49 (07056) 3017 FAX: 49 (07056) 8540
Toll Free in Germany: 0130 11 21 66
e-mail: germany omega.com
25 Swannington Road, PO Box 7, Omega Drive,
Broughton Astley, Leicestershire, Irlam, Manchester,
LE9 6TU, England M44 5EX, England
Tel: 44 (1455) 285520 Tel: 44 (161) 777-6611
FAX: 44 (1455) 283912 FAX: 44 (161) 777-6622
Toll Free in England: 0800-488-488
e-mail: uk omega.com
@
@
@
@
OM-EL-PANEL-IR
10
TxD
RxD
RS232 driver
1
e.g. MAX232
Isolation
barrier
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of
from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal
to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each
warranty
product.
Ifthe unit should malfunction, itmust be returned tothe factory for evaluation.OMEGA’sCustomerService Department willissue
anAuthorizedReturn (AR) number immediatelyupon phone or writtenrequest.UponexaminationbyOMEGA,ifthe unit is found
to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any
actionofthe purchaser,includingbutnot limited to mishandling, improperinterfacing,operationoutsideof design limits, improper
repair,orunauthorizedmodification.This WARRANTY is VOIDif the unit showsevidenceof having been tampered withor shows
evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification;
misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted,
includingbutnotlimitedtocontactpoints,fuses,andtriacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes
responsibilityfor any omissions or errorsnor assumes liability forany damages that result from the use of its products
in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts
manufactured by it will be specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL
IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are
exclusive and the total liability of OMEGA with respect to this order,whether based on contract, warranty,negligence,
indemnification,strict liability or otherwise, shall not exceed the purchase price of the component upon which liability
isbased.InnoeventshallOMEGAbeliableforconsequential,incidentalorspecialdamages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under
10CFR21 (NRC), used in or withanynuclearinstallation or activity;or (2) in medical applicationsorused on humans.Shouldany
Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way,
OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and additionally, purchaser
will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s)insuchamanner.
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY
PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S
CUSTOMERSERVICEDEPARTMENT(INORDERTOAVOIDPROCESSING DELAYS).The assignedAR number should then
bemarkedontheoutsideofthereturn package and on any correspondence.
Thepurchaserisresponsibleforshippingcharges,freight,insuranceandproperpackagingtopreventbreakageintransit.
WARRANTY NON-WARRANTY
FOR RETURNS,pleasehavethefollowing FOR REPAIRS,consultOMEGAfor
informationavailableBEFORE contacting OMEGA: currentrepaircharges.Havethefollowinginformation
1.P.O.numberunderwhichtheproductwasPURCHASED, availableBEFORE contacting OMEGA:
2.Modelandserialnumberoftheproductunderwarranty, 1. P.O.numbertocovertheCOSTofrepair,
and 2. Modelandserialnumberofthe product, and
3.Repairinstructionsand/orspecificproblemsrelativeto 3.
theproduct. theproduct.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our
customersthelatestintechnologyandengineering.
OMEGAisaregisteredtrademarkofOMEGA ENGINEERING, INC.
© Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written
consentofOMEGAENGINEERING,INC.
Itisthepolicyof OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply.OMEGAisconstantlypursuingcertification of
itsproductstotheEuropeanNew Approach Directives.OMEGAwilladd the CE mark to every appropriate deviceuponcertification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc.acceptsno liability for any errors it contains,
andreservestherighttoalterspecificationswithout notice.
Theseproductsarenotdesignedfor use in, and should notbeusedfor,patient connected applications.WARNING:
WARRANTY/DISCLAIMER
RETURNREQUESTS/INQUIRIES
LT1081
one (1) year product
Repairinstructionsand/orspecificproblemsrelativeto
13 months