AdjustAble Frequency
Ac drives
NFX9000 Series
NFXF50A0-1
shown smaller
than actual size.
l V/Hz Control: Provides 150%
Starting Torque and Advanced
Low Speed Control
l Easy to Understand Keypad
l RS485 Serial
Communication Port
l Single-Phase or 3-Phase
Input Capability on 115/240 Vac
Rated Units
Cutler-Hammer® NFX9000 adjustable
frequency AC Drives from Eaton’s electrical
business are designed to provide adjustable
speed control of 3-phase motors. These
microprocessor-based drives have standard
features that can be programmed to tailor
the drive’s performance to suit a wide variety
of application requirements. The NFX9000
volts-per-hertz product line utilizes a 32-bit
microprocessor and insulated gate bipolar
transistor (IGBTs) which provides quiet
motor operation, high motor efficiency and
smooth low speed performance. The size
and simplicity of the NFX9000 make it ideal
for hassle-free installation where size is a
primary concern.
Models rated at 240V, single- or
3-phase, 50/60 Hz are available in sizes
ranging from
115V, single-phase, 50/60 Hz are available
in the
drive includes a digital display as well as
operating and programming keys on a
removable keypad. The display provides
drive monitoring and diagnostic information.
The keys are utilized for digital adjustment
and programming of the drive plus operator
control. Separate terminal blocks for control
and power wiring are provided for customer
connections. The drives feature RS485 serial
communications.
1
⁄4 to 2 hp. Models rated at
1
⁄4 to 1⁄2 hp size range. The standard
SPECIFICATIONS
OUTPUT RATINGS
Horsepower: 90 to 132V, 1⁄4 to 1⁄2 hp,
200 to 240V, 1⁄2 to 2 hp
Frequency Range: 0.1 to 400 Hz
Overload Rating: 150% for 60 sec
Frequency Resolution: Digital, 0.1 Hz
Frequency Accuracy:
Digital: ± 0.01% of maximum frequency
Analog: ± 0.2% of maximum frequency
Undervoltage Carryover Limit:
0.3 to 25 sec
MOTOR PERFORMANCE
Motor Control: V/Hz
Constant Torque: Standard
Speed Regulation: 0.5% of base speed
INPUT POWER
Voltage: 50/60 Hz, ±3 Hz
100 to 120V: -10% +10%/1-phase
200 to 240V: -10% +5%/1-phase
200 to 240V: -10% +5%/3-phase
Displacement Power Factor:
Better than 0.95
Efficiency: Typically greater than 95%
DESIGN TYPE
Microprocessor: 32-bit
Converter Type: Diode
Inverter Type: Insulated Gate Bipolar
Transistor
Waveform: PWM V/Hz
ENVIRONMENT
Operating Temperature: -10 to 40°C
(14 to 104°F)
Humidity: 20 to 90% non-condensing
Maximum Elevation: 1000 m (3281')
1
Dimensions: mm (inch)
132.0
(5.20)
5.0 (0.20)
68.0 (2.68)
56.0 (2.20)
R/L1 S/L2 T/L3
RUN
FWD
REV
MIN. MAX.
RA RC +1 0V AVID1
RUN
STOP
NFX9000
0.5 HP
230V 1 PHASE
!
WARNING
D2 D3 D4 GND
U/T1 V/T2 W/T3
STOP
MODE
RESET
ENTER
RS-485
120.0
(4.72)
CODES AND STANDARDS
NEMA, IEEE, NEC: Design standards,
UL listed, cUL listed, CE marked
Standard Enclosure: Protected chassis
(IP20)
PROTECTIVE FEATURES
Ground Fault: Standard
Overload Protection: Standard
Overcurrent: Standard
Overvoltage: Standard
Undervoltage: Standard
Overtemperature: Standard
Overload Limit: Standard
SET UP ADJUSTMENTS,
PERFORMANCE FEATURES,
OPERATOR CONTROL AND
EXTERNAL INTERFACE
Keypad:
Alphanumeric Display: Standard,
1 x 4 character
Digital Indications: RUN/STOP and
FORWARD/REVERSE
Diagnostics: Last 3 trips with cause
Dia.
RS-485
128.1
123.4
(5.04)
(4.86)
LED Status Indicators: 4; RUN/STOP
and FORWARD/REVERSE
Operator Functions: RUN/STOP,
speed control (digital or
potentiometer), RESET, MODE
keys and ENTER
I/O TERMINAL BLOCK
Analog Inputs: 1 Input, 0 to 10 Vdc,
4 to 20 mA
Potentiometer: 1 to 2K Ω
Analog Voltage: Nominal 10 Vdc,
10K Ω input impedance
Analog Current: Nominal 4 to 20 mA,
250 Ω
Digital Inputs: 4 programmable inputs
Digital Outputs: 1 form A relay contact
PROGRAMMABLE PARAMETERS
Out of the Box: Factory settings loaded
for quick start-up
Acceleration and Deceleration:
2 separately, adjustable linear or S curve
times, 0.1 to 600 sec
DC Injection Braking:
External Fault: Terminal input
Jog: Terminal input
Fault Reset: STOP/RESET or
terminal input
I/O: NO/NC selectable
Jump Frequencies:
3, with adjustable width
Parameter Security: Programmable
software lock
Preset Speeds: 2 preset speeds
Reversing: Keypad or terminal
Speed Setting: Keypad, terminal or pot
RUN/STOP Control: Keypad or terminal
Stop Modes: Decel, coast or
DC injection
RELIABILITY
Pretested Components: Standard
Surface Mount Technology:
Standard, PCBs
Computerized Testing: Standard
Final Test with Full Load: Standard
Eaton’s Cutler-Hammer Engineering
Systems and Service: National network
of AF drive specialist
To Order Visit omega.com/nfx9000_series for Pricing and Details
INPUT AMP
MODEL NO. DESCRIPTION AMPERE RATING
115 VOLT
NFXF50A0-1
1
⁄2 hp single phase, watt loss: 20 W 9.0 2.50
230 VOLT
NFXF25A0-2 Micro drive 0.25 Hp 230 Vac V/Hz (open chassis), watt loss: 20 W 4.9 1.6
NFX001A0-2 Micro drive 1 Hp 230 Vac V/Hz (open chassis), watt loss: 38 W 9.7 4.2
NFX002A0-2 Micro drive 2 Hp 230 Vac V/Hz (open chasis), 3 ph, watt loss: 75 W 9.0 7.0
Comes with operator’s manual.
Ordering Example: NFXF50A0-1, 1⁄2 Hp single phase, 20 W loss.
2