N-30
N
⻬ Small, Economical
⻬ 2-Wire, 4 to 20 mA Output
⻬ Thermocouple, RTD,
and mV Inputs
⻬ Automatic Cold-Junction
Compensation
⻬ Automatic Self-Calibration
The TX66 “smart” transmitters offer
isolation, linearization, automatic
temperature compensation, automatic
self-calibration, and easy-to-use
menus. These compact units accept
a large number of inputs. The
optional 1-line display will fit within
the same footprint as the
transmitter. The 2-line,
plug-in display is
slightly larger, with
2 pushbuttons
and LCD glass.
Both displays
are field
mountable.
At least 1 display
is required to
set up and
scale the
transmitter.
To Order
(Specify Model Number)
Model No. Price Description
TX66A $310 Basic transmitter
TX67A
††
340 Intrinsically safe
transmitter
Comes complete with operator’s manual.
Note: TX60-2A required for scaling input in
the field.
††
Intrinsic safety barrier required.
FM/CSA Entity Parameters
V
max
= 30 Vdc I
max
= 125 mA
C
I
= 1.2 nF LI= 80 µH P
max
= 90 mW
Class 1, Div 1, Groups A, B, C, D
Ordering Example: TX67A, intrinsically safe
transmitter, TX60-2A, 2-line digital display,
$340 + 159 = $499.
“Smart” Temperature
Transmitters
TX66A transmitter shown
with explosion-resistant
housing (included with some
models, see table).
Both models shown
smaller than actual size.
Model Number Price Description
TX60-2A $159 2-line, plug-in display
NEP-TX-66A-(*) 465 TX66A in explosion-resistant housing with SS
1
⁄
4
" OD, 12" long unearthed thermocouple
NEP-TX-66A-RTD 505 TX66A in explosion-resistant housing with
1
⁄
4
" OD, 12" long, 100 Ω Platinum RTD
NEP-TX-67A-(*) 495 TX67A in explosion-resistant housing with SS
1
⁄
4
" OD, 12" long unearthed thermocouple
NEP-TX-67A-RTD 535 TX67A in explosion-resistant housing with
1
⁄
4
" OD 12" long, 100 Ω Platinum RTD
Additional Models
*
Add thermocouple Type (J, K, T or E).
Ordering Example: NEP-TX-66A-K, TX66A transmitter in an explosion-resistant housing,
12" unearthed thermocouple,
1
⁄
4
" OD, Type K probe with
1
⁄
2
NPT, $465.
OCW-3, OMEGACARESMextends standard 2-year warranty to a total of 5 years ($116),
$465 + 116 = $581.
Input Type
Range Accuracy
°C °F °C °F
100 to 1800 212 to 3272 ±0.6 ±1.08
0 to 2320 32 to 4208 ±0.5 ±0.9
-50 to 1000 -58 to 1832 ±0.2 ±0.36
-180 to 750 -292 to 1382 ±0.2 ±0.36
-180 to 1250 -292 to 2282 ±0.2 ±0.36
L
-200 to 900 -328 to 1652 ±0.4 ±0.72
0 to 1200 32 to 2192 ±0.2 ±0.36
0 to 1600 32 to 2912 ±0.5 ±0.9
0 to 1550 32 to 2822 ±0.5 ±0.9
-150 to 400 -238 to 752 ±0.3 ±0.54
U
-100 to 600 -148 to 1112 ±0.4 ±0.72
100 Ω Pt RTD
1
-200 to 850 -328 to 1562 ±0.08 ±0.14
100 Ω Pt RTD
2
-200 to 645 -328 to 1193 ±0.08 ±0.14
Millivolt -15 to 115 mV ±0.006 mV
Ω 0 to 500 Ω ±0.002 Ω
TX60-2A,
2-line
plug-in
display,
$159.
TX66A
transmitter,
$310.
Additional
power supplies
available, please see
pages N-50 to 54
for details.
TX66A Series
Starts at
$
310
Specifications
Linearization: ±0.05°C
Output:
Analog: 2-wire
Digital: 4 to 20 mA
Minimum Output Range: None
Output Rezolution:
Analog: 3.5 µA
Digital: 4 significant digits
Accuracy:
Digital: ±0.03% of the mV or equivalent
reading or the accuracy from the table
below, whichever is greater
Analog: Digital accuracy plus ±4 µA,
typical, ±8 µA max
Repeatability: One half of accuracy
Failsafe: User-programmable for high,
low, or off
Operating Temp Range:
Transmitter: -40 to 85°C (-40 to 185°F)
Display: -20 to 70°C (-4 to 158°F)
0 to 100% RH (non-condensing)
Isolation: 500 Vdc or Vac p-p;
operating input-output voltage:
250 Vac p-p or ±250 Vdc
Power and Load: 12 to 48 Vdc; V
SUPPLY
(MIN) = 12 + (R
LOAD
in kΩ) x 23 mA
Common-Mode Rejection: 120 dB
Reverse Polarity Protection:
42 Vdc applied with either polarity
Dimensions: 41 mm H x 61 Dia.
(1.6 x 2.4")
Weight: 227 g (8 oz)
MOST POPULAR MODELS HIGHLIGHTED!
1
European curve (␣= 0.00385).
2
American curve (␣= 0.003923). Call factory for special units with 100 Ω Ni, 120 Ω Ni and 10 Ω Cu.