Omega Products MVX001A0-4 User Manual

SenSorleSS Vector AdjuStAble Frequency Ac driVeS
MVX005A0-2 shown smaller than actual size.
MVX9000 Series
l Sensorless Vector Control
with Auto Tuning
l Easy to Understand Keypad l PID Control of a Process
l Built-In Dynamic
Braking Chopper
l RS485 Serial Communication Port l Single-Phase or 3-Phase Input
Capability on 240 Vac Rated Units, 3 hp and Below
MVXF25A0-1 shown smaller than actual size.
The Cutler-Hammer® MVX9000 Series sensorless vector adjustable frequency AC Drives from Eaton’s electrical business are designed to provide adjustable speed control of 3-phase motors. These microprocessor­based, sensorless vector drives have standard features that can be programmed to tailor the drive’s performance to suit a wide variety of application requirements. The MVX9000 sensorless vector series utilizes a 32-bit microprocessor and insulated gate bipolar transistor (IGBTs) which provides quiet motor operation, high motor efficiency and smooth low speed performance. The size and simplicity of the MVX9000 Series makes it ideal for hassle free installation where size is a primary concern. Models rated at 480V, 3-phase, 50/60 Hz are available in sizes ranging from 1 to 10 hp. Models rated at 240V, single- or 3-phase, 50/60 Hz are available in sizes ranging from 0.5 to 7 Models rated at 115V, single-phase, 50/60 Hz are available in the range. The standard drive includes a digital display, operating and programming keys on a removable keypad. The display provides drive monitoring as well as adjustment and
1
4 to 1 hp size
1
2 hp.
DESCRIPTION DIMENSIONS IN mm (inch) SHIPPING WEIGHT HORSEPOWER VOLTS WIDTH HEIGHT DEPTH KG (LBS)
1⁄4 to 1 100 - 120 100 (3.9) 151 (5.9) 145 (5.7) 2.8 (6.2)
1
2 to 2 200 - 240 100 (3.9) 151 (5.9) 145 (5.7) 2.8 (6.2) 3 to 7 1 to 3 380 - 480 100 (3.9) 151 (5.9) 145 (5.7) 2.8 (6.2) 5 to 10 380 - 480 125 (4.9) 220 (8.6) 193 (7.6) 5.5 (12.1)
diagnostic information. The keys are utilized for digital adjustment and programming of the drive and for operator control. Separate terminal blocks for control and power wiring are provided for customer connections. Other features provided as standard include built-in DC braking, RS485 serial communications and PID control.
SPECIFICATIONS
OUTPUT RATINGS Horsepower: 90 to 132V, 1⁄4 to 1 hp
200 to 240V: 380 to 480V: 1 to 10 hp 425 to 660V: 1 to 10 hp
Frequency Range: 0.1 to 400 Hz Overload Rating: 150% for 60 sec Frequency Resolution:
Digital: 0.1 Hz Analog: Max (set frequency/1000) Hz
1
2 200 - 240 125 (4.9) 220 (8.6) 193 (7.6) 5.5 (12.1)
Frequency Accuracy: Digital: ±0.01% of max frequency
Analog: ±0.2% of max frequency Undervoltage Carryover Limit:
0.3 to 25 sec
MOTOR PERFORMANCE Motor Control: Sensorless vector Constant and Variable Torque:
Standard Speed Regulation: 0.5% of base speed
1
2 to 71⁄2 hp
INPUT POWER Voltage: 50/60 Hz ±3 Hz
100 to 120V: -10% +10%/1-phase 200 to 240V: -10% +5%/1-phase 200 to 240V: -10% +5%/3-phase 380 to 480V: -10% +10%/3-phase 500 to 600V: -15% +10%/3-phase
Displacement Power Factor: Better than 0.95
1
Efficiency: Typically greater than 95% DESIGN TYPE
Microprocessor: 32-Bit Converter Type: Diode Inverter Type: Insulated gate
bipolar transistor
Waveform: Sensorless vector ENVIRONMENT
Operating Temperature: -10 to 50°C
(14 to 122°F), -10 to 40°C (14 to 104°F); above 7
1
2 hp)
Humidity: 20 to 90%, non-condensing Maximum Elevation: 1000 m (3281') Codes and Standards: NEMA, IEEE,
NEC, design standards, UL Listed, cUL listed, CE marked (requires EMI filter)
Enclosure: Standard, protected chassis (IP20)
PROTECTIVE FEATURES Ground Fault: Standard Overload Protection: Standard Overcurrent: Standard Overvoltage: Standard Undervoltage: Standard Overtemperature: Standard Overload Limit: Standard
SET UP ADJUSTMENTS, PERFORMANCE FEATURES, OPERATOR CONTROL AND EXTERNAL INTERFACE KEYPAD
Alphanumeric Display: Standard,
1 x 4 character Digital Indications: Frequency (Hz),
Motor Current (amps), User-Defined RUN/STOP, FORWARD/REVERSE and parameters
Diagnostics: Last 3 trips with cause LED Status Indicators: 8; RUN/STOP,
FORWARD/REVERSE, Hz, amps, user defined, and input speed
Operator Functions: START/STOP, speed control (digital or potentiometer), RESET, SETUP keys and ENTER
I/O TERMINAL BLOCK Analog Inputs: 2 Inputs; 0 to 10 Vdc,
4 to 20 mA
Potentiometer: 1 to 2 KΩ Analog Voltage: Nominal 10 Vdc,
10K Ω input impedance Analog Current: Nominal
4 to 20 mA, 250 Ω
Digital Inputs: 6 programmable inputs Digital Outputs: 1 programmable
open collector and 1 form C relay contact
Analog Monitor Output: Analog meter; frequency or output current dynamic brake chopper
PROGRAMMABLE PARAMETERS
Accel. and Decel.: 2 separately
adjustable linear or S curve times;
0.1 to 3000 sec Auto Restart: Overcurrent, overvoltage
and undervoltage with 4 selectable retry restart modes
DC Injection Braking: External Fault: Terminal input Jog: Terminal input
Fault Reset: STOP/RESET or terminal input
I/O: NO/NC Selectable Jump Frequencies: 3; with
adjustable width Parameter Security: Programmable
software lock
Preset Speeds: 7 preset speeds PID Controller: PID process control Reversing: Keypad or terminal Speed Setting: Keypad, terminal or pot START/STOP Control: Keypad
or terminal Stop Modes: Decel, coast or
DC injection
RELIABILITY Pretested Components: Standard Surface Mount Technology:
Standard (PCBs) Computerized Testing: Standard Final Test with Full Load: Standard
Eaton’s Cutler-Hammer Engineering Systems and Service: National network
of AF drive specialists
Out of the Box: Factory settings loaded for quick start-up
To Order Visit omega.com/mvx9000 for Pricing and Details
INPUT AMP. CONT. WATT SINGLE/ OUTPUT LOSS AT MODEL NO. DESCRIPTION 3 PH RATING AMP RATING 9 KHZ
115 VOLT
MVXF25A0-1 0.25 hp AC drive, 1 ph input, 230V, 3 ph output 6.3/* 1.6 20.0 MVXF50A0-1 0.5 hp AC drive, 1 ph input, 230V, 3 ph output 9.0/* 2.5 20.0
230 VOLT
MXVF50A0-2 0.5 hp AC drive, 1 ph/3 ph input, 3 ph output 6.3/2.9 2.5 20.0 MVX001A0-2 1 hp AC drive, 1 ph/3 ph input, 3 ph output 11.5/6.3 5.0 38.0 MVX002A0-2 2 hp AC drive, 1 ph/3 ph input, 3 ph output 15.7/8.8 7.0 75.0 MVX003A0-2 3 hp AC drive, 1 ph/3 ph input, 3 ph output 27.5/12.5 10 110 MVX005A0-2 5 hp AC drive, 3 ph input, 3 ph output */19.6 17.0 185.0 MVX007A0-2 7.5 hp AC drive, 3 ph input, 3 ph output */31.5 25.0 275.0
460 VOLT
MVX001A0-4 1 hp AC drive, 3 ph input 460V, 3 ph output */4.2 3.0 38.0 MVX002A0-4 2 hp AC drive, 3 ph input 460V, 3 ph output */5.7 4.0 75.0 MVX003A0-4 3 hp AC drive, 3 ph input 460V, 3 ph output */7.0 5.0 110.0 MVX005A0-4 5 hp AC drive, 3 ph input 460V, 3 ph output */10.5 8.2 185.0 MVX007A0-4 7.5 hp AC drive, 3 ph input 460V, 3 ph output */14.0 13.0 275.0 MVX010A0-4 10 hp AC drive, 3 ph input 460V, 3 ph output */20.6 18.0 375.0
Comes complete with operator’s manual. * Not applicable. Horsepower ratings are based on the use of a 240 or 480V NEMA B, 4- or 6-pole squirrel cage induction motor and are for reference only. Units are to be selected such that the motor current is less than or equal to the MVX9000 rated continuous output current. For 208V, 380V or 415V applications, select the unit such that the motor current is less than or equal to the MVX9000 rated continuous output current.
Ordering Examples: MVXF25A0-1, 0.25 hp AC drive, 115V 1 ph input, 230V 3 ph output. MVX003A0-2, 3 hp AC drive, 230V 1 ph/3 ph input, 230V 3 ph output.
2