Omega Products MDS-DTM-RTD User Manual

Battery Powered Benchtop Meter
Single-Channel RTD Models with Wireless Option
Available with
Built‑In Wireless
Antenna connection for wireless option.
Large 25 mm
(1") Digits
Transmitter Option
MDS-DTM-RTD Series
Optional
U Large Multicolor Backlit
Display with 25 mm (1") Digits Readable From Over 10.7 m (35')
U Up to ±0.2°C (±0.3°F) or
±0.1% Rdg Accuracy
U Connects Directly to
3-Wire Pt100 RTD Sensors
U Powered by Internal
Battery or External DC Power Supply
U Included Setup and
Service Software Allows for Fast Maintenance and Calibration via USB Connection
U Wireless Transmitter
Option Sends Readings to Remote Locations and Allows for PC-Based Chart
Recording and
Data Logging
U Low Power Operation
and Sleep Mode for Long Battery Life
U Display Backlight
Changes from Green to
Blue for Low Alarm and
from Green to Red for High Alarm
U Portable, Rugged Metal
Benchtop Enclosure with Tilt Handle
U User-Friendly, Simple to
Configure
U High Quality
M-1
MDS-DTM-RTD-W with wireless
transmitter option, shown
smaller than actual size.
The OMEGA® MDS-DTM-RTD is a rugged benchtop metal enclosure featuring a large backlit LCD display that incorporates both large 25 mm (1") digits and a 25 segment bar graph that makes reading at distances up to 10.7 m (35') easy. Models are available with or without wireless capability. Standard features include: internal battery, external DC power supply operation, analog output and user programmable alarms. The wireless transmitter option allows for remote monitoring, chart recording and data logging. A variety of user­configurable options and settings include: update rate, dampening, units, backlight, and auto-off.
M
Specifications
Range: -51 to 538°C (-60 to 1000°F)
(depending on sensor selected) Accuracy: ±0.2°C (±0.3°F) or ±0.1%
of reading
Resolution: 0.1°C (0.1°F) Operating Environment: -40 to 70°C
(-40 to 158°F) 5-100% RH non-condensing
RTD Probe/Sensor Input: Pt100, 3-wire Display Type: LCD with selectable
backlight
Display Digits: 4 digits, 9999 counts Character Height: 25.4 mm (1.0") Computer Interface: USB (one
programming cable included) Input Type: RTD, analog voltage,
analog current RTD Input (ITS 68): 100/500/1000 Ω
Pt sensor, 2-, 3-, or 4-wire; 0.00385 or
0.00392 curve Sample/Display Rate: User adjustable
from 0.375 to 30 sec, preset to 1/sec Power: Two “D” size alkaline batteries
included, 12 to 24 Vdc
Battery Life (Typical): 2 years* Analog Output: 0 to 5 Vdc, 0 to 10 Vdc,
or 4 to 20 mA; Requires external 12 to 24 Vdc power supply for operation
Enclosure: Case—aluminum, handle—aluminum
Enclosure Finish: Case—painted, handle—anodized
Settings (USB/Software) Auto-Off: Locked-on, 1 min, 2 min,
5 min, 10 min, 15 min, 30 min, 60 min
Units: °F, °C, K Lock: Allows for front button “lock-out”
Without wireless option
*
Alarms: User selectable “high” and “low” alarm limits
Analog Output: User selectable scaling Backlight: On/off, or 10 sec, 30 sec,
1 min, 5 min Wireless Transmitter (Optional):
Channel number, transmission rate, alarms, sensor offset, chart recording, data logging
Dimensions:
93.47 H x 206.50 W x 203.20 mm D (3.68 x 8.13 x 8.00"), height not including sensor
Calibrate: Zero and span Weight: 1.2 kg (2.65 Ib)
Wireless Option Specifications
Transmit Sample Rate: User
programmable from 1 sample/2 min to 1 sample/every 2 sec
Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz
RF Output Power: 10 dBm (10 mW) Range of RF Link:
Outdoor Line of Sight:
Up to 120 m (400')
Indoor/Urban: Up to 40 m (130')
Software (Included Free): Requires
Windows Internal Battery: Two (2) “D” size
Alkaline batteries; recommended battery type: Duracell batteries for the best performance at low temperatures
Data Transmitted to Host: Temperature reading, ambient temperature reading, RF transmit strength and battery level
®
2000, XP or Vista (32 bit)
®
type MN1300 “D” size
Visit omega.com/
wireless
for Details
Wireless Receivers
UWTC-REC4
receiver.
Receive data from up to 48 transmitters, and provide a scalable retransmitted, hard wired analog output for 4 user selected transmitters in your system.
UWTC-REC1.
Large 25 mm (1") Digits
25 Segment Bargraph
High Alarm Backlight
Read From Up to 10.7 m (35') Away!
Receive data from up to 48 transmitters, powered directly by the USB connection on your computer.
UWTC-REC3 32-channel receiver with ethernet.
Temperature
Units (°C/°F)
Low Alarm Backlight
Receiver/host with ethernet is compatible
with UWTC and UWRTD connectors,
transmitters and wireless probe
assemblies. Connects directly to your
network or the Internet—no PC required!
M-2
MDS-DTM-RTD Benchtop Meter Wireles Versions
MDS-DTM-RTD-M8-W model
shown with M8 RTD connector
input, wireless option, alarm
output, and analog output.
MDS-DTM-RTD-W model shown with terminal RTD input, wireless option, alarm output, and analog output.
* Wireless Models Include FREE Monitoring, Charting and Data Logging Software For Your PC!
* Supplied with receivers
MDS-DTM-RTD-M12-W model shown with M12 RTD connector input, wireless option, alarm output, and analog output.
All models shown smaller than actual size.
M-3MM-4
Typical Multi-Unit Wireless Data Logging System
Up to 122 m (400')
UWTC-REC1 USB
MDS-DTM-RTD-M12-W with M12C-PUR-4-S-F-10 polyurethane cable.
All models shown
smaller than actual size.
MDS-DTM-RTD-W with PR-10-2-100-1/4-6-E general purpose RTD probe.
receiver.
Laptop not included.
To Order Visit omega.com/mds-dtm-rtd for Pricing and Details
Model No. Description MDS-DTM-RTD Benchtop meter with RTD terminal block input connection, alarm output,
analog output MDS-DTM-RTD-W Wireless benchtop meter with RTD terminal block input connection, alarm
output, analog output* MDS-DTM-RTD-M8 Benchtop meter with RTD M8 input connection, alarm output, analog output MDS-DTM-RTD-M8-W Wireless benchtop meter with RTD M8 input connection, alarm ouput,
analog output* MDS-DTM-RTD-M12 Benchtop meter with RTD M12 input connection, alarm output, analog output
MDS-DTM-RTD-M12-W
Wireless benchtop meter with RTD M12 input connection, alarm output,
analog output*
Comes complete with operator’s manual, USB cable, user software, and two alkaline “D” cell batteries.
* Units with the wireless option require a UWTC series receiver or transceiver to operate.
Ordering Example: UWTC-REC1, 48 channel USB receiver.
MDS-DTM-RTD-M12, benchtop meter with RTD M12 input connection, alarm output, analog output, and UWTC-REC1, 48 channel USB receiver.
MDS-DTM-RTD-M8-W, wireless benchtop meter with RTD M8 input connection, alarm output, analog output, and
Accessories
Model No. Description UWTC-REC1 Wireless 48-channel USB receiver (used with wireless option only)
UWTC-REC4(**) 48-channel DIN rail wireless receiver with 4 analog outputs and alarms
UNIV-AC-100/240 Replacement universal 9 Vdc adaptor
CAL-3 NIST traceable calibration (meter only) 3 points CAL-3-SYSTEM NIST traceable calibration (meter with probe) 3 points
** Specify analog output signal: “V1” for 0 to 5 Vdc; “V2” for 0 to 10 Vdc, “TC” for Type K Thermocouple, or “MA” for 4 to 20 mA signal.