Omega Products G7L-2A-BUBJ-CB-AC200-240 User Manual

GENERAL PURPOSE
HIGH-CURRENT RELAYS
G7L-2A-TUB-J-CB-AC100/120, $21.50.
G7L Series
Starts at
$
19
l Ideally Suited for High-Inrush Fluid Pump Controls:
Such as Pool/Spa, Water Processing, Emergency, Chemical Industry
l High-Capacity, High-Withstand Voltage Relay with
No Contact Chattering for Momentary Voltage Drops Up to 50% of Rated Voltage
Used for all Insulation Material
l Quick-Connect and Screw Terminals Available
25
Bottom view
The G7L Series relays are general purpose panel-mount relays that are extremely compact. They are available with a DC coil voltage of 24 Vdc and AC coil voltages of 24, 120, and 240 Vac. The GL Series is available in SPST and DPST versions (NO contacts) and have a continuous current rating of 30A (resistive loads).
SPECIFICATIONS
Contact Resistance: 50 m max Operate Time: 30 ms max Release Time: 30 ms max Max Operating Frequency:
Mechanical: 1800 operations/hour
Electrical: 1800 operations/hour (under rated load) Insulation Resistance: 1000 M min (at 500 Vdc) Dielectric Strength:
4000 Vac: Min/5000 Vac typical, 50/60 Hz for 1 minute
between coil and contacts
2000 Vac: 50/60 Hz for 1 minute between contacts of
same pole
2000 Vac: 50/60 Hz for 1 minute between contacts of
different poles (DPST-NO type) Impulse Withstand Voltage: Between coil and contact;
10,000V min/12,000V typ (impulse wave used: 1.20 x 50 µs)
Vibration:
Mechanical and Malfunction Durability: 10 to 55 Hz;
1.50 mm (0.06") double amplitude
Shock:
Mechanical and Malfunction Durability: 1000 m/s
(approx 100 G)
Life Expectancy:
Mechanical: 1,000,000 operations min (at 1800
operations/hour)
G7L-2A-BUBJ-CB-DC24, $27.50.
Bottom view
Electrical: 100,000 operations min (at 1800 operations/hour
2
under rated load 250,000 ops typical)
Ambient Temperature: -25 to 60°C (-13 to 140°F) Humidity: 35 to 85% RH Weight:
Quick-Connect Terminal: Approx 90 g (3.17 oz) Screw Terminal: Approx 120 g (4.23 oz)
K-1
CONTACT DATA
Switching Voltage (V)
Switching Current (A)
AC resistive load
AC inductive load (p.f. = 0.4)
100
50
30
20
10
7
5
3
1
10 30
50 70
100 300
500
1000
Switching Current (A)
Service Life (X 10 Operations)
3
220 Vac resistive load
220 Vacinductive load (p.f. = 0.4)
5000
3000
1000
700
70 50
500
300
100
0 5 10
15 20
25 30
G7L-1A-T, G7L-1A-B G7L-2A-T, G7L-2A-B
Resistive load Inductive load Resistive load Inductive load (p.f. = 1) (p.f. = 0.4) (p.f. = 1) (p.f. = 0.4)
RATED LOAD 30 A at 220 Vac 25 A at 220 Vac
CONTACT MATERIAL AgSnIn
CARRY CURRENT 30 A 25 A
MAX OPERATING VOLTAGE 250 Vac
MAX OPERATING CURRENT 30 A 25 A
MAX SWITCHING CAPACITY 6600 VA 5500 VA
COIL DATA
AC COILS
MUST OPERATE MUST RELEASE MAXIMUM
RATED RATED COIL
VOLTAGE (V) CURRENT (mA) RESISTANCE ()
24 71 303 75% max 15% min 110% max 1.70 to 2.50 VA 100/120 17.0/20.4 5260 75V 18V 132V 1.70 to 2.50 VA 200/240 17.0/20.4 5260 75V 18V 132V 1.70 to 2.50 VA
DC COILS
24 79 303 75% max 15% min 110% max 1.90 W
VOLTAGE VOLTAGE VOLTAGE
(% OF RATED VOLTAGE)
POWER
CONSUMPTION
Maximum Switching Capacity
Electrical Service Life
K-2
Loading...
+ 2 hidden pages