Omega Products G3NA-210B-AC100-120 User Manual

omegamation.com omegamation.com
GENERAL PURPOSE SOLID STATE RELAYS (SSR)
G3NA Series
Starts at
$
20
Current Ratings to 90 Amps
Multi-Million Hour Life
Compatible with Temperature
Controllers
Solid-State, SCR Design
Zero Voltage Switching
(AC Loads)
Built-In Varistor Effectively
Absorbs External Surges
Control AC Loads to 400 Vac
Control DC Loads to 200 Vdc
AC and DC Control Signal Models
LED Operation Indicator
Thermal Conductive Pad Included
The G3N series of solid state relays are used to control large resistance heaters in conjunction with temperature controllers. Solid state relays are SPST, normally open switching devices with no moving parts, capable of millions of hours of operation. By applying a control signal, an SSR switches ON the AC (or DC) load current, just as the moving contacts do on a mechanical relay. Three-phase loads can be controlled using 2 or 3 SSR’s. Use 3 SSR’s for Y or star 3-phase loads using a neutral line. Two SSR’s will control “delta” loads with no neutral line. Three solid state relays are also used when there is no neutral load to provide redundancy and extra assurance of control.
“Switching” takes place at the zero voltage crossover point of the alternating current cycle. Because of this, no appreciable electrical noise is generated, making SSR’s ideal for environments where there are apparatuses susceptible to RFI.
50
G3NA-240B-DC5-24,
$45, shown actual size.
SPECIFICATIONS
Operate Time:
G3NA-205B, G3NA-210B, G3NA-220B, G3NA-240B, G3NA-420B, G3NA-440B, G3NA-450B:1⁄2 of load power source
cycle + 1 mS max (DC input), 3⁄2 of load power source cycle + 1 mS max (AC input) G3NA-D210B: 1 mS max (DC input), 30 mS max (AC input)
Release Time:
G3NA-205B, G3NA-210B, G3NA-220B, G3NA-240B, G3NA-420B, G3NA-440B, G3NA-450B:1⁄2 of load power source
cycle + 1 mS max (DC input), 3⁄2 of load power source cycle + 1 mS max (AC input) G3NA-D210B: 5 mS max (DC input), 30 mS max (AC input)
Output ON Voltage Drop:
G3NA-205B, G3NA-210B, G3NA-220B, G3NA-240B:
1.6 V (RMS) max
G3NA-420B, G3NA-440B, G3NA-450B: 1.8 V (RMS) max G3NA-D210B: 1.5 V max
Leakage Current:
G3NA-205B, G3NA-210B, G3NA-220B, G3NA-240B: 5 mA max
(@ 100 Vac), 10 mA max (@ 200 Vac)
Leakage Current Cont:
G3NA-420B, G3NA-440B, G3NA-450B: 10 mA max (@ 200 Vac)
20 mA max (@ 400 Vac)
G3NA-D210B: 5 mA max (@ 200 Vdc)
Insulation Resistance: 100 M min
(@ 500 Vdc) Dielectric Strength: 2500 Vac,
50/60 Hz for 1 min Vibration Resistance: Destruction;
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock Resistance: Destruction; 1000 m/s
Ambient Temperature:
Ambient Humidity: Operating, 45 to 85% Weight:
2
Operating: -30 to 80°C (-22 to 176ºF) (with no icing or condensation) Storage: -30 to 100°C (-22 to 212ºF) (with no icing or condensation)
G3NA-205B, G3NA-210B, G3NA-220B: Approx 60 g G3NA-240B, G3NA-D210B: Approx 70 g G3NA-420B, G3NA-440B, G3NA-450B: Approx 80 g
SHOP
ONLINE AT
To download information and to order automation products online, visit omegamation.com
1
1-888-55-663421-888-55-66342
1-888-55-OMEGA1-888-55-OMEGA
TM
HOTLINE TO
AUTOMATION
PRODUCTS
12
34
((−)) (+)(+)
4.5 (0.17) 25
(0.98)
Load
4.5 dia
(0.17)
dia
43 (1.69)
max
Terminal Arrangement/ Internal Connections (Top View)
11.9
(0.47)
58
(2.28)
max
47.5
(1.87)
44
(1.73)
Four, M4 x 8 screws
Operating
Indicator
Height will be 30 mm for all G3NA-420B (-UTU) models manufactured after July 1, 2010
15.8 (0.62)
25 (0.98) max 27 (1.06)
47.6
(1.87)
±0.2
Two, 4.3 dia or M4 holes
Mounting Holes
Output
Input
Load
power
supply
Load
12
34
()(+)
Mounting Holes
Terminal Arrangement/ Internal Connections (Top View)
4.5 (0.17) 25
(0.98)
4.5 dia (0.17)
dia
43 (1.69)
max
11.9
(0.47)
58
(2.28)
max
47.5
(1.87)
44
(1.73)
Two, M5 x 12 screws
Operating
Indicator
Height will be 30 mm for all G3NA-240B/2500B (-UTU) models manufactured after July 1, 2010
47.6
(1.87)
±0.2
Two, 4.3 dia or M4 holes
Output
Load
power
supply
Two, M4 x8 screws
15.8 (0.62)
25 (0.98) max 27 (1.06) max
Input
Load
12
34
(−) (+)
+
Mounting Holes
Terminal Arrangement/ Internal Connections (Top View)
4.5 (0.17) 25
(0.98)
4.5 dia (0.17)
dia
43 (1.69)
max
11.9
(0.47)
58
(2.28)
max
47.5
(1.87)
44
(1.73)
Four, M4 x 8 screws
Operating
Indicator
47.6
(1.87)
±0.2
Two, 4.3 dia or M4 holes
Output
Load
power
supply
15.8 (0.62)
25 (0.98) max 27 (1.06) max
Input
Note: When connecting the load,
either the positive or negative side of the load terminals can be connected.
Note: The load can be connected to either the positive or negative side.
G3NA-205B, G3NA-210B, G3NA-220B, G3NA-420B
G3NA-240B, G3NA-440B
2
omegamation.com for new details!
G3NA-D210B
Relays and timers product line
continues to expand, visit
Loading...