Omega Products FTB8007HW-PT User Manual

HOT WATER METERS FOR TOTALIZATION AND RATE INDICATION WITH PULSE OUTPUT
FTB8000HW Series
Starts at
$
191
FTB8015HW-PR, $690
All models shown
smaller than actual size.
Flow Rates from
0.22 to 132 GPM
150 psi Maximum
Operating Pressure
Operating Temperature
Field-Adjustable Pulse
Output (Optional)
FTB8015HW-PR, $690
FTB8007HW-PR, $240
The FTB8000HW Series meters use the multi-jet principle, which has been an internationally accepted standard for many years. This type of meter is known for its wide range, simplicity, and accuracy in low­quality water. The impeller is centered in a ring of jets, with inlet jets on one level and outlet jets on another. A gear train drives the register totalizer dials. For pulse output, one of the dials is replaced by a gear, which turns a magnet that is detected by an encapsulated sensor threaded into the outside of the lens. Pulse rate is determined by the gear and the dial on which
F-X
F
the gear is placed. Changing the pulse rate requires no special tools and can be done in the field.
Mechanically, all FTB8000HW meters are the same. The difference between the -PR, -PT, and standard models is in the sensor. -PR model meters use a solid state, long­lasting Hall-effect sensor, which requires power. -PT model meters use a 2-wire reed switch. They provide a dry-contact closure and do not require power. Basic FTB8000HW meters totalize only and do not have an output. Never install water meters above or over areas where leakage would cause damage.
A
B
C
D
Typical Pressure Drop Curve
3
/4'' 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25
1'' 5 10 15 20 25 30 35 40 45 50
1
1
/2'' 10 20 30 40 50 60 70 80 90 100
2'' 13 26 39 52 65 78 91 104 117 130
Rate of flow in gallons per minute (GPM)
Pressure drop in P.S.I.
20 15 10
5 0
Top removes
with no
special tools
Either pulse sensor
threads into
lens without removing top
Dimensions: cm (in)
Cast bronze body
(meets AWWA
specifications)
Union end couplings
for easy service
1
2 2
3
) 30 (11
4
5
) 45 (17
8
22
1
2 2
1
2 2
3
)
4
5
)
8
1
2
3
4
3
4
1
) 26 (10
2
5
8
3
4
11
1
) 30 (11
4
) 40 (15
5
) 45 (17
8
1
4
11
11
NPT Size A (Body) 19 (7 B (w/Couplings) 32 (12 C (IPS Thread) 11 D (NPT Thread)
NPT Size
20* ———
Pulses per 10 ———
Gallon 2* 2* 2* 2*
1111
1111
5* 5* 5* 5*
Gallons per 10 10 10 10
Pulse 50* 50* 50* 50*
100 100 100 100
* These pulse rates are only available on units with the “-PT” option.
SPECIFICATIONS
Materials:
Body: Cast bronze Internals: Engineered thermoplastic
Magnet: Permanent ceramic Max Temperature: 90°C (194°F) Max Operating Pressure: 150 psi Accuracy: 1.5% of reading Sensor:
-PR: Hall-effect device
-PT: Reed switch Max Current: 20 mA Max Voltage:
-PR: 24 Vdc
-PT: 24 Vdc or Vac Sensor Power (-PR):
Minimum 6 mA at 12 Vdc Cable Length: 3.7 m (12') standard, 610 m (2000') max
Flow Rates (GPM):
NPT Size3⁄4 111⁄2 2 Minimum 0.22 0.44 0.88 1.98
Maximum 22 52 88 132
MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)
Model No. Price NPT Size (GPM) (Default Setting) FTB8007HW $191
3
4 0.22 to 22 None, total only
FTB8010HW 305 1 0.44 to 52 None, total only FTB8015HW 585 11⁄2 0.88 to 88 None, total only FTB8020HW 765 2 1.98 to 132 None, total only FTB8007HW-PT 240
3
4 0.22 to 22 20
FTB8010HW-PT 335 1 0.44 to 52 1 FTB8015HW-PT 690 11⁄2 0.88 to 88 1 FTB8020HW-PT 865 2 1.98 to 132 1 FTB8007HW-PR 240
3
4 0.22 to 22 1
FTB8010HW-PR 335 1 0.44 to 52 1 FTB8015HW-PR 690 11⁄2 0.88 to 88 1 FTB8020HW-PR 865 2 1.98 to 132 1
Comes complete with MNPT couplings, 3.7 m (12') cable and operator’s manual. Ordering Examples: FTB8015HW-PR, 88 GPM max flow rate water meter with adjustable pulse
output set to 1 pulse per gallon with hall effect sensor, $690. FTB8010HW-PR, 52 GPM max with adjustable pulse output set to 1 pulse per gallon with hall
effect sensor, $335.
Recommended Reference Book: Water Resources Handbook,
ES-2022, $140. Visit omega.com/bobi for Additional Books.
F-X
Flow Range Pulses per Gallon
Loading...