U 29 Engineering Units
(Including User Defined)
U Two Programmable Totalizers
U Programmable Alarms
U Isolated Analog 0 to 5 Vdc or
4 to 20 mA
U RS232 Communications
Standard
U Local Key Pad and 2 x 16
Characters LCD Display
U Free Communication Software
with Data Logging Capability
F
FP1400 Series flowmeters support various functions
including; two independently programmable flow
totalizers, user programmable low, high or range flow
and temperature alarm, two sets of user programmable
optically isolated outputs, self diagnostic alarm, and
flow pulse output. The flow rate can be displayed
in 29 different volumetric or mass flow engineering
units. Flowmeter parameters and functions can be
programmed locally via optional key pad and LCD
or remotely via the RS232/RS485 interface. Local
2 x 16 LCD readout with adjustable backlight provides
flow rate, temperature, total volume reading in
currently selected engineering units, diagnostic events
indication and feature a password protected access to
the process parameters to ensure against tampering
or resetting.
Liquid flowing through the unit causes the paddlewheel
to spin. As the magnets embedded in the paddle spin
past the sensor, electrical pulses are produced in
which frequency is proportional to the flow rate. The
number of pulses per desired time interval and the
K-factor (number of pulses/gal) make it is possible to
calculate the flow rate and volume passing through
the unit. On board CPU and signal conditioner circuitry
perform accurate flow and total computation, digital
communication and analog 0 to 5 Vdc or 4 to 20 mA
output signals. Non-volatile memory stores all hardware
specific and user programmable variables, including
flow linearization table.
FP1408 shown larger
than actual size.
SPECIFICATIONS
Viscosity: 1 cSt (water) can be used for liquids up to 50 cSt
with field calibration (max flow range may be affected)
Flow Accuracy (Including Linearity): ±1% of FS
Repeatability: ±0.25% of FS
Temperature Measurement Range: 60°C (140°F)
Temperature Accuracy (Including Linearity): ±0.5°C
Flow Response Time: Approx 1 sec (above 10% of full scale
flow), approx 2 seconds (below 10% of full scale flow)
Maximum Pressure: 10 bar (150 psig)
Maximum Pressure Drop: @ 15 psi for sized units @ 20 psi
all other sizes
Ambient Temperature: -10 to 60°C (14 to 140°F)
Output Signals:
Linear 0 to 5 Vdc (3000 Ω minimum load impedance); linear
4 to 20 mA (500 Ω maximum loop resistance). Maximum
noise 20 mV peak to peak (for 0 to 5 Vdc output)
Flow Pulse Output: 3.3 Vdc amplitude
(3000 Ω min load impedance)
Optically Isolated Outputs: UCE 40 Vdc, ICE 150 mA
Power: 11 to 26 Vdc, 100 mV maximum peak to peak
output noise
Consumption: +12 Vdc (150 mA maximum); +24 Vdc (100
mA maximum); circuit board have built-in polarity reversal
protection, 300 mA resettable fuse provide power input
protection
Communications: RS232 standard, RS485 (optional)
F-1
Also available on remote display.
FPB1400 Series with DPF701 meter.
Visit omega.com/fpb1400
FPB1406
Both models shown
smaller than actual size.
PVDF Models
Body: PVDF
LID: PVDF
Paddle Wheel: PVDF
Shaft: Zirconia ceramic
Bearings: Sapphire jewels
O-RINGS: PTFE
RTD: 316 SS casing
Electrical Connections: Built-in
female 12-pin M16, NEMA 4X (IP67)
connector. To be mated with 12-pin
M16 male EMI shielded NEMA 4X
(IP67) connector (sold separately)
Display: Optional local 2 x 16
characters LCD with adjustable
backlight (2 lines of text)
Keypad: Optional 4 pushbutton key pad
CE Compliant: EMC Compliance with
89/336/EEC as amended. Emission
Standard: EN 55011:1991, Group
1, Class A Immunity Standard: EN
55082-1:1992
To Order
Visit omega.com/fp1400 for Pricing and Details
DPF701
Visit omega.com/dpf701
Wetted Materials
Polypropylene Models
Body: Polypropylene
LID: Acrylic
Paddlewheel: PVDF
Shaft: Nickel tungsten carbide
Bearings: Sapphire jewels
O-Rings: EPDM
RTD: 316 SS casing
Maximum
Model No. Ports Pressure Drop Range
Model No. Description with RTD NPT bar (psi) GPM
FP1402 Polypropylene flowmeter, with display FP1402-RTD ³⁄₈ 1 (15) 0.5 to 5
FP1404 Polypropylene flowmeter, with display FP1404-RTD ¹⁄₂ 1.4 (20) 1 to 10
FP1406 Polypropylene flowmeter, with display FP1406-RTD ³⁄₄ 1.4 (20) 2 to 20
FP1408 Polypropylene flowmeter, with display FP1408-RTD 1 1.4 (20) 3.5 to 35
FP1412 PVDF flowmeter, with display FP1412-RTD ³⁄₈ 1 (15) 0.5 to 5
FP1414 PVDF flowmeter, with display FP1414-RTD ¹⁄₂ 1.4 (20) 1 to 10
FP1416 PVDF flowmeter, with display FP1416-RTD ³⁄₄ 1.4 (20) 2 to 20
FP1418 PVDF flowmeter, with display FP1418-RTD 1 1.4 (20) 3.5 to 35
Accessories
DPF701 ¹⁄₈ DIN digital display, 115 Vac 7.5 to 13 Vdc powered
FP1400-CABLE 12-pin cable
Comes complete with operator’s manual.
For units with RS485 communications in place of RS232 add suffix “-485” to the model number, no additional charge.
Ordering Example: FP1404, polypropylene flowmeter with display 1 to 10 GPM range,
1
⁄
NPT connections.
2
F-2