integral or remote
signal conditioner
FLSC-C3-LIQ
U DC or AC Powered
U Pulse and Analog Outputs
U High and Low Alarms (Optional)
U 20 Point Linearization
U Factory Configuration
Available
U Windows
Configuration
Software*
The FLSC-C3-LIQ is a DC powered,
microprocessor controlled
transmitter. It outputs a pulse scaled
per unit of flow, and analog signal
proportional to flow rate. The
FLSC-C3-LIQ-AL can be configured
with high and low alarms. They are
designed for integral mounting to
the FTB-100 and FTB-200 Series**
liquid turbines.
Visit omega.com/ftb100 and
**
omega.com/ftb200 for details
®
³⁄₄-14 NPT
Conduit
Hubs
121
(4.75)
133
(5.23)
FLSC-C3-LIQ shown
smaller than actual size.
122
140
(5.5)
156
(6.125)
(4.81)
Dimensions: mm (inch)
92
(3.63)
7.9
(0.31)
F
SPECIFICATIONS
Input Signal Type: Magnetic pickup,
MCP pickup, contact closure, pulse
Input Frequency Range: 0.2 Hz to 4 KHz
Signal Level: 10 mV rms to 30 Vdc
Power Supply: 13 to 30 Vdc reverse
polarity protection
Analog Output: 4 to 20 mA, 1 to 5V
24 mA overflow condition
Load Resistance: Maximum 650 Ω at
24 Vdc
Accuracy: ±0.02% of full scale
Temperature Drift: 40 ppm/degree C
Pulse Output: 0 to 5V, 0 to 10V, open
collector, AC square. Internal pull up
10 kΩ. Recommended minimum
load resistance 50 kΩ
Pulse Scaling: Divide by 1, 10 or 100 per
flow unit
Hi/Lo Alarm (-AL Model) Optional:
Relay (2A, 30 Vdc), 0 to 5V, open
collector (0.5A, 30V)
Communications: RS232 port for
configuration and diagnostics
Operating Temperature: -40 to 85ºC
(-40 to 185°F)
6 (0.25) Diameter Mounting Holes
Enclosure meets Class I, Div 1 & 2, Groups A, B, C & D. Class 1, Zones 1 & 2,
Groups IIB + H2IIA. Class ll, Div 1 & 2 Groups E, F & G. Class lll. NEMA 3, 4 7(B, C, D)
9(E, F, G). Cenelec EEx d llC IP66, UL, CSA, FM Approved. ATEX Certified.
Humidity: 0 to 90% non-condensing
Enclosure: Extruded aluminum
explosion-proof ATEX
To Order Visit omega.com/flsc-c3-liq for Pricing and Details
Model No. Description
FLSC-C3-LIQ DC powered signal conditioner 4 to 20 mA, CE ATEX
FLSC-C3-AL-LIQ DC powered signal conditioner 4 to 20 mA, alarm CE ATEX
OM-CONV-USB USB to RS232 converter
FLSC-C-CABLE Molex to 9-pin “D” connector
Comes complete with operator’s manual and enclosure.
Available free at omega.com/ftp
*
Ordering Example: FLSC-C3-LIQ, DC powered turbine signal conditioner with
FLSC-C-CABLE Molex to 9-pin “D” connector.
Regulatory: CE Compliant up to 20 point
linearization Windows
Software* (cable sold separately)
®
Configuration
F-1