OMEGA®high accuracy integral signal conditioners are designed for direct mounting onto OMEGA FTB-100 and 200 Series turbine meters. The input circuitry of the signal conditioners has been designed to receive and condition low level turbine meter signals while rejecting unwanted noise and spurious signals. A signal threshold control is provided which allows the user to set the input sensitivity above the ambient noise level, thereby eliminating any false signal on the output. Signal conditioners are available that can provide 4 to 20 mA, 0 to 5V, and scaled frequency pulse outputs that run on unregulated power supplies. Other units which run off 115 Vac provide both an unscaled pulse output and a 0 to 5V or 4 to 20 mA output. A zero and a span potentiometer allow for simple field adjustment of the analog outputs from the signal conditioners.
®
SPECIFICATIONS
Accuracy: See “To Order” box Temperature Range:
0 to 70°C (32 to 158°F) Pulse Output: TTL/CMOS; open
collector for FLSC-51B Input Frequency: 10-1000 Hz, 28 mV
P-P; 1000-2500 Hz, 70 mV P-P. Can be used with any OMEGA
®
Turbine Meter
Maximum Input: 120V RMS Electrical Connections:
Screw terminals Maximum Lead Length: 305 m (1000')
of 24 gage copper wire for pulse or mA; 30 m (100') for 0 to 5V output.
Weight: 2.3 kg (5 lb)
Signal Conditioner (Enclosure Mounted) Only
To Order
Model No. Price Output Power
FLSC-18B $586 4 to 20 mA
FLSC-34 822
FLSC-28 603 0 to 5V
FLSC-35B 822
FLSC-51 586
FLSC-51B 586 pulse, 50 ms @10 mA ±1% FS
Signal conditioners are installed at no charge when purchased with turbine meter. Note: The use of explosion-proof heads does not imply that complete assembly is either
explosion-proof or intrinsically safe. It is the user’s responsibility to determine the suitability of materials for a given installation.
Comes complete with operator’s manual. Ordering Examples: SYS/FTB-101/FLSC-18B, turbine and signal conditioner system, $1765,
see page F-57. SYS/FTB-201/FLSC-34, turbine and signal conditioner, $2001, see page F-60.
(Specify Model Number)
F-59
MOST POPULAR MODELS HIGHLIGHTED!
4 to 20 mA with 115 Vac
unscaled pulse 50/60 Hz
0 to 5V with 115 Vac
unscaled pulse 50/60 Hz
scaled squarewave 8 to 35 Vdc
pulse, 2 ms duration @10 mA
scaled squarewave 8 to 35 Vdc
duration
Signal Compatible Meters
Conditioners Model No. (Page)
FLSC-18B, FLSC-34 DPF50 (M-9), DPF60 (M-21) FLSC-28, FLSC-35B DPF300 (M-29), DPi8 (M-35)
FLSC-51 DPF70 (M-22), DPF701 (M-5)
Input
8 to 40 Vdc
@30 mA
10 to 40 Vdc
@10 mA
Accuracy
±0.05% FS
±0.1% FS
±0.5% FS
±0.1% FS
±1% FS
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...