LOW FLOW TURBINE METERS
For Liquid and Gas Applications
FLR1000 Series
†
Optional
U PPS or Brass Construction
U 1% Accuracy for Liquids
U Up to 0.2% Repeatability
U 0 to 5V Analog Output
U Available With or Without Display
FLR1000 Series flow sensors can measure extremely
low flow rates from 20 mL/min to 5 L/min. These
sensors are suitable for a wide variety of industrial,
commercial, and laboratory flow applications.
FLR1000 Series flow sensors operate on 12 Vdc
power and are designed for incorporation into data
acquisition systems that supply 12.5 Vdc to sensors
and receive 0 to 5 Vdc linear signals in return.
Because of their cost effectiveness, FLR1000 Series
units may replace conventional glass tube and ball
flowmeters in applications in which an electrical signal
proportional to flow rate is desired.
The FLR1000 Series uses a Pelton-type turbine wheel
to determine the flow rate of the gas. The rotation
rate of the turbine wheel is linear over a wide dynamic
range. The electro-optical system consists of a diode
emitting energy in the infrared spectrum. Light energy
is alternatively reflected and absorbed from “spokes”
deposited on the small turbine wheel. This reflected
light energy is detected by a photodiode. Thus, as
the turbine wheel rotates in response to gas flow rate,
electrical pulses are generated. Processing circuitry
provides a DC voltage output proportional to the flow
rate. For example, output signal is 1.0 Vdc at 20%
of rated flow, 2.5 Vdc at 50% of rated flow, 4.0 Vdc
at 80% of rated flow, and 5.0 Vdc at 100% of rated
flow. Sensors can handle 20% above their rated flow
without being damaged.
For liquid flow metering with integrated rate display,
the FLR1000ST-D Series has been setting the pace.
Their advanced Pelton-turbine design provides
high turndown ratios, fast response, and repeatable
accuracy. A 0 to 5 Vdc analog output is standard.
Featuring a 31⁄2-digit display of flow rate in engineering
units, these flowmeters are perfect for any laboratory
or test facility. For higher-pressure applications or
where metal may be required, the FLR1000ST Series
is the solution, see page F-89 for complete details.
†, ††
Refer to footnote on next page for NIST calibration
ordering information.
Specifications
(FLR1000 Series)
Accuracy: ±1% FS (liquids), ±3% (gases)
Display: 31⁄2 -digit LCD, 22 mm (7⁄8") H
Output Signal: 0 to 5 Vdc, adjustable ±20% (typical)
Power Requirement: 11.5 to 15 Vdc regulated,
30 mA (typical)
Standard Sensor Material: 40% glass filled polyphenelene
sulfide, glass window, stainless steel bearing support;
sapphire shaft and bearing; FKM rubber O-rings standard
FLR1001, shown
actual size.
FLR1009ST-D,
shown actual size.
Visit omega.com for
deatails.
F-87
Pressure Rating: 40 psi at 20°C (68°F)
for gas, 100 psi for liquid, 500 psi for
brass units using liquid services
Temperature Rating: 0 to 50°C
(32 to 122°F)
Temperature Sensitivity: ±0.2%/°C
Linearity: ±3% FS
Repeatability: ±0.5% FS from 50 to
100% of rated max flow for gas;
Dimensions:
Display: 76 x 44 x 89 mm
(3 x 1.75 x 3.5")
Non-Display: 60 x 42 x 37 mm
(2.35 x 1.65 x 1.25")
Pressure Sensitivity: ±0.07%/mm
Hg (using air at 1 to 3 atm)
Mounting: Holes for #4 screw
provided
±0.2% FS for liquid
Cable Assembly: 0.9 m (3’)
cable length
Options
Order
Suffix Description Compatible Units
-BR Brass body Liquid: FLR1007-1013
-P Pulse output Liquid: FLR1007-1013
-BR-D Brass body Gas: FLR1001-1006, FLR1201
and display Liquid: FLR1007-1013
-BR-P Brass body Liquid: FLR1007-1013
and pulse output
FLR1010-D, shown
smaller than
actual size.
To Order Visit omega.com/flr1000 for Pricing and Details
Model No. † Model No. †Gas
HIGHLIGHTED MODELS AVAILABLE FOR FAST DELIVERY!
(No Display) (Display) Flow Range Max Pressure Drop (psi) Acetal Tube Fitting (in)
FLR1001 FLR1001-D 20 to 100 mL/min 20 ¹⁄₈
FLR1002 FLR1002-D 40 to 200 mL/min 8 ¹⁄₈
FLR1003 FLR1003-D 100 to 500 mL/min 2 ¹⁄₈
FLR1004 FLR1004-D 200 to 1000 mL/min 2 ¹⁄₈
FLR1005 FLR1005-D 0.4 to 2.0 L/min 2 ¹⁄₄
FLR1006 FLR1006-D 1.0 to 5.0 L/min 2 ¹⁄₄
FLR1201 FLR1201-D 2.0 to 10.0 L/min 3 ¹⁄₄
FLR1202 FLR1202-D 4.0 to 20.0 L/min 3 ³⁄₈
FLR1203 FLR1203-D 10 to 50 L/min 3 ³⁄₈
FLR1204 FLR1204-D 20 to 100 L/min 3 ¹⁄₂
FLR1205 FLR1205-D 40 to 200 L/min 5 ¹⁄₂
FLR1206 FLR1206-D 100 to 500 L/min 20 ¹⁄₂
Model No. †† Model No. †† Liquid Max Pressure Acetal Tube
(No Display) (Display) Flow Range Drop (psi) Fitting (in)
FLR1007 FLR1007-D 13 to 100 mL/min 10 ¹⁄₈
FLR1008 FLR1008-D 20 to 200 mL/min 10 ¹⁄₄
FLR1009 FLR1009-D 50 to 500 mL/min 10 ¹⁄₄
FLR1010 FLR1010-D 100 to 1000 mL/min 6 ¹⁄₄
FLR1011 FLR1011-D 0.2 to 2.0 L/min 6 ¹⁄₄
FLR1012 FLR1012-D 0.5 to 5.0 L/min 6 ³⁄₈
FLR1013 FLR1013-D 1 to 10 L/min 10 ³⁄₈
F
Accessories
Model No. Description
FLR1000-PW 115 Vac power supply
FLR1000-230PW 230 V power supply with European connector
FLR1000-C35 Replacement 0.9 m (3') cable
† For a 4-point NIST calibration for air, add suffix “-NISTAIR” to model number for additional cost.
†† For a 4-point NIST calibration for water add suffix “-NISTWATER” to model number, for additional cost, (FLR1007 calibrations are 3-points).
Comes complete with 0.9 m (3') cable and operator’s manual.
Ordering Examples: FLR1012, liquid flow sensor, 0.5 to 5.0 L/min range.
FLR1006-D, gas flow sensor with display, 1.0 to 5.0 L/min range.