Omega Products DP63700-AC User Manual

M-59
1
8 DIN Digital Panel Meters
For AC True RMS Voltage and Current
Specifications
Display: 5-digit, 14 mm (0.56") red
Power:
AC Versions:
AC Power: 85 to 250 Vac,
50/60 Hz, 15 VA Isolation: 2300 Vrms for 1 min
to all inputs and outputs
Keypad: 3 programmable function keys, 5 keys total
A/D Converter: 16-bit resolution
Update Rates:
A/D Conversion Rate: 20 readings/s Step Response: 200 ms max to within
99% of final readout value (digital filter and internal zero correction disabled); 1 s max to within 99% of final readout value (digital filter disabled)
Display Update Rate: 1 to 20 updates/s Setpoint Output On/Off Delay Time:
0 to 3275 seconds
Analog Output Update Rate: 0 to 10 s Max/Min Capture Delay Time:
0 to 3275 seconds
The DP63700 Series panel meters offer many features and performance capabilities to suit a wide range of industrial applications. Models include AC true RMS voltage/current inputs. The optional plug-in output cards allow the opportunity to configure the meter for present applications while providing easy upgrades for future needs. The meters have a bright 14 mm (0.56") LED display. The unit is available with a red, sunlight­readable or a standard green LED. The intensity of display can be adjusted from dark-room- to sunlight-readable, making it ideal for viewing in bright light applications.
The meters provide a max and min reading memory with programmable capture time. The capture time is used to prevent detection of false max or min readings which may occur during start-up or unusual process events.
DP63700-AC
Starts at
$
317
AC True RMS Voltage
and Current Meter
1
8 DIN (50 x 97 mm)
5-Digit, LED Display
14 mm (0.56")
Green or Red Sunlight-
Readable Display
4 Voltage Ranges
(300 Vac Max) and 5 Current Ranges (5 A Max)
Field-Upgradeable
Option Cards
3-Way Isolation: Power,
Input and Outputs
NEMA 4X (IP65)
The meters have up to 4 setpoint outputs, implemented on plug-in option cards. The plug-in cards provide dual form “C” relays (5A), quad form “A” (3A), or either quad­sinking or quad-sourcing open collector logic outputs. The setpoint alarms can be configured to suit a variety of control and alarm requirements. Communication and bus capabilities are also available as option cards. These include RS232, RS485, and MODBUS®.
Memory: Non-volatile EEPROM retains all programmable parameters and display values
Environmental Conditions
Operating Temperature Range:
0 to 50°C (32 to 122°F) [0 to 45°C (32 to 113°F) with all 3 plug-in cards installed]
Storage Temperature Range:
-40 to 60°C (-40 to 140°F)
Operating and Storage Humidity:
0 to 85% max RH non-condensing
Altitude: Up to 2000 meters Connections: High-compression,
cage-clamp terminal block Construction: This unit is rated for
NEMA 4X (IP65) outdoor use, IP20 touch-safe, Installation Category II, Pollution Degree 2, 1-piece bezel/case, flame-resistant, synthetic rubber keypad—panel gasket and mounting clip included
Weight: 295 g (10.4 oz)
True RMS AC Voltage/Current
Isolation to Option Card Commons and User Input Commons: 125 Vrms
Isolation to AC Power Terminals:
250 Vrms
Maximum Crest Factor (Vp/VRMS):
5 @ FS Input
Input Coupling: AC, or AC and DC Input Capacitance: 10 pF Common Mode Voltage:
125 Vac working
Common Mode Rejection:
(DC to 60 Hz) 100 dB Output Modules: For complete
specifications, see LDP63100 Series, page M-100
DP63700-AC,
$317, shown smaller than
actual size.
Panel punches
available, visit
omega.com/
panelpunches
M-60
M
To Order
(Specify Model Number)
Model No. Price Description (Display Meter Only, No Outputs) DP63700-AC $317 AC inputs, red display, 85 to 250 Vac, 50/60 Hz DP63700-AC-GN 334 AC inputs, green display, 85 to 250 Vac, 50/60 Hz DPP-5 525
1
8 DIN panel punch
EE-1319 85 Reference Book: Grounding and Shielding Techniques
Optional Plug-in Output Cards (Field Installable)
*
Free DP6-SOFT software download available at omega.com/dp63700. Comes complete with operator’s manual. Note: Adding option cards—meters can be fitted with up to 3 optional plug-in cards, however, only 1 card from each function type can be
installed at a time. The function types include setpoint alarms, analog output and communications. The cards can be installed initially or at a later date. Each optional plug-in card is shipped with installation and programming instructions.
Ordering Example: DP63700-AC, AC inputs, red display, 85 to 250 Vac, 50/60 Hz, LDP6-CDC20, RS232 serial communications output card with terminal block, $317 + 48 = $365.
Dimensions: mm (in)
Model No. Price Description
Setpoint Alarms (Only 1 Alarm Card Can Be Installed Into Base Meter)
LDP6-CDS10 $37 Dual setpoint relay output card
LDP6-CDS20 37 Quad setpoint relay output card
LDP6-CDS30 37 Quad setpoint sinking open collector output card
LDP6-CDS40 37 Quad setpoint sourcing open collector output card
Analog Output
LDP6-CDL10 $74 Analog output card
Communications (Only 1 Communications Card Can Be Installed Into Base Meter)*
LDP6-CDC10 $48 RS485 serial communications output card with terminal block
LDP6-CDC1C 48 Extended RS485 serial communications output card with dual RJ11 connector
LDP6-CDC20 48 RS232 serial communications output card with terminal block
LDP6-CDC2C 48 Extended RS232 serial communications output card with 9-Pin D connector
LDP6-CDC40 58 MODBUS communications card
LDP6-CDC4C 58 Extended MODBUS communications card with dual RJ11 connector
Input Max DC Impedance Continuous
Range Accuracy* Blocking (60 Hz) Overload Resolution
200 mV 0.1% of rdg
+ 0.4 mV ±10V 686 kΩ 30V 0.01 mV
2V 0.1% of rdg
+ 2 mV ±50V 686 kΩ 30V 0.1 mV
20V 0.1% of rdg
+ 20 mV ±300V 686 kΩ 300V 1 mV
300V 0.2% of rdg
+ 0.3V ±300V*** 686 kΩ 300V 0.1 V
200 µA 0.1% of rdg
+ 0.4 µA ±15 mA 1.11 kΩ 15 mA 0.01 µA
2 mA 0.1% of rdg
+ 2 µA ±50 mA 111 Ω 50 mA 0.1 µA
20 mA 0.1% of rdg
+ 20 µA ±150 mA 11.1 Ω 150 mA 1 µA
200 mA 0.1% of rdg
+ 0.2 mA ±500 mA 1.1 Ω 500 mA 10 µA
5 A 0.5% of rdg
+ 5 mA ±7 A*** 0.02 Ω 7 A** 1 mA
True RMS Voltage/Current Inputs
*
Conditions for accuracy specification: 20 minutes warm-up, 18 to 28°C (64 to 82°F) temperature range, 10 to 75% RH non-condensing, 50 Hz to 400 Hz sine wave input, 1% to 100% of range. Add 0.1% reading + 20 counts error over 0 to 50°C (32 to 122°F) range, 0.2% reading + 10 counts error for crest factors up to 3, add 1% reading up to 5, 0.5% reading + 10 counts of DC component and 1% reading + 20 counts error over 20 Hz to 10 KHz range.
**
Non-repetitive surge rating: 15 A for 5 seconds
***
Inputs are directly coupled to the input divider and shunts. Input signals with high DC
component levels may reduce the usable range.
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 53.4 (2.1) H x 127 (5) W.
49.5
(1.95)
96.5
(3.80)
v
91.4
(3.60)
44.5
(1.75)
2.5
(0.10)
104.1 (4.10)
44.5
(1.75)
AVAILABLE FOR FAST DELIVERY!
Loading...
+ 1 hidden pages