Omega Products DP63600-DC User Manual

M-57
1
8 DIN Digital Panel Meters
For DC Voltage and Current Inputs
Specifications
Display: 5-digit, 14.2 mm (0.56") red
Power:
AC Versions:
AC Power: 85 to 250 Vac,
50/60 Hz, 15 VA Isolation: 2300 Vrms for 1 minute
to all inputs and outputs
DC Power: 11 to 36 Vdc, 11 W (derate operating temperature to 40°C if operating <15 Vdc and 3 plug-in option cards are installed)
AC Power: 24 Vac, ± 10%, 50/60 Hz, 15 VA
Isolation: 500 Vrms for 1 minute to all inputs and outputs (50V working)
Keypad: 3 programmable function keys, 5 keys total
A/D Converter: 16-bit resolution Update Rates:
A/D Conversion Rate: 20 readings/s Step Response: 200 ms max to
within 99% of final readout value (digital filter and internal zero correction disabled), 700 ms max (digital filter disabled, internal zero correction enabled)
Display Update Rate: 1 to 20 updates/s
The DP63600 Series panel meters offer many features and performance capabilities suitable for a wide range of industrial applications. These meters accept universal DC voltage/current inputs. The optional plug-in output cards allow the opportunity to configure the meter for present applications, while providing easy upgrades for future needs.
The meters employ a bright,
14.2 mm (0.56") LED display. The unit is available with a red sunlight readable or a standard green LED. The intensity of display can be adjusted from dark room to sunlight readable, making it ideal for viewing in variable light applications.
The meters provide a max and min reading memory with programmable capture time. The capture time is used to prevent detection of false max or min readings which may occur during start-up or unusual process events.
DP63600
Starts at
$
254
Universal DC Input Green Display or
Red Sunlight-Readable Display
5-Digit, 14.2 mm
(0.56") LED
4 V (300 Vdc Max) and
5 Current (2A dc Max) Ranges
3 Resistance Ranges—
10 KΩ Max
Field-Upgradeable
Option Cards
AC and DC Powered
Versions
NEMA 4X (IP65)
The meters have 4 setpoint outputs, implemented on plug-in option cards.The plug-in cards provide dual form “C” relays (5A), quad form “A” (3A), or either quad-sinking or quad-sourcing open collector logic outputs. The setpoint alarms can be configured to suit a variety of control and alarm requirements. Communication and bus capabilities are also available as option cards; these include RS232, RS485, and MODBUS®.
Setpoint Output On/Off Delay Time:
0 to 3275 seconds
Analog Output Update Rate:
0 to 10s
Max/Min Capture Delay Time:
0 to 3275 s Memory: Non-volatile EEPROM
retains all programmable parameters and display values
Environmental Conditions:
Operating Temperature Range:
0 to 50°C (32 to 122°F) [0 to 45°C (32 to 113°F) with all 3 plug-in cards installed]
Storage Temperature Range:
-40 to 60°C (-40 to 140°F)
Operating and Storage Humidity:
0 to 85% max RH non-condensing
Altitude: Up to 2000 m (6562')
Connections: High-compression,
cage-clamp terminal block Construction: This unit is rated for
NEMA 4X (IP65) outdoor use, IP20 touch-safe, Installation Category II, Pollution Degree 2, 1-piece bezel/case, flame-resistant, synthetic rubber keypad—panel gasket and mounting clip included
Weight: 295 g (10.4 oz)
Excitation Power
Transmitter Power: 24 Vdc, ±5%,
regulated, 50 mA max
Reference Voltage: 2 Vdc, ±2% Compliance: 1 kΩ load min (2 mA max) Temperature Coefficient:
40 ppm/°C max
Reference Current: 1.75 mAdc, ±2% Compliance: 10 kΩ load max Temperature Coefficient:
40 ppm/°C max Output Modules: For complete
specifications, see LDP63100 Series, page M-100
DP63600-DC, $254,
shown smaller
than actual size.
Panel Punches
Available, Visit
omega.com/panelpunches
M-58
M
To Order
(Specify Model Number)
Model No. Price Description (Display Meter Only, No Outputs) DP63600-DC $254 Universal DC inputs, red display, 85 to 250 Vac, 50/60 Hz DP63600-DC-LV 282 Universal DC inputs, red display, 11 to 36 Vdc, 24 Vac DP63600-DC-GN 269 Universal DC inputs, green display, 85 to 250 Vac, 50/60 Hz DP63600-DC-GN-LV 297 Universal DC inputs, green display, 11 to 36 Vdc, 24 Vac
MOST POPULAR
MODELS HIGHLIGHTED!
Optional Plug-in Output Cards (Field Installable)
*
Free software available at omega.com/dp63600-dc Comes complete with operator’s manual. Note: Adding option cards—meters can be fitted with up to 3 optional plug-in cards, however, only 1 card from each function type can be
installed at a time. The function types include setpoint alarms, analog output and communications. The cards can be installed initially or at a later date. Each optional plug-in card is shipped with installation and programming instructions.
Ordering Examples: DP63600-DC-GN, universal DC inputs, green display, 85 to 250 Vac, 50/60 Hz, and LDP6-CDL10 analog output card, $269 + 74 = $343.
DP63600-DC, universal DC inputs, red display, 85 to 250 Vac, 50/60 Hz, $254.
Dimensions: mm (in)
Model No. Price Description
Setpoint Alarms (Only 1 Alarm Card Can Be Installed Into Base Meter)
LDP6-CDS10 $37 Dual setpoint relay output card
LDP6-CDS20 37 Quad setpoint relay output card
LDP6-CDS30 37 Quad setpoint sinking open collector output card
LDP6-CDS40 37 Quad setpoint sourcing open collector output card
Analog Output
LDP6-CDL10 $74 Analog output card
Communications (Only 1 Communications Card Can Be Installed Into Base Meter)*
LDP6-CDC10 $48 RS485 serial communications output card with terminal block
LDP6-CDC1C 48 Extended RS485 serial communications output card with dual RJ11 connector
LDP6-CDC20 48 RS232 serial communications output card with terminal block
LDP6-CDC2C 48 Extended RS232 serial communications output card with 9-Pin D connector
LDP6-CDC40 58 MODBUS communications card
LDP6-CDC4C 58 Extended MODBUS communications card with dual RJ11 connector
Max
Input Accuracy Accuracy Impedance/ Continuous
Range (18 to 28°C) ( 0 to 50°C) Compliance Overload Resolution
±200 µAdc
0.03% of rdg 0.12% of rdg + 0.03 µA + 0.04 µA
1.11 kΩ 15 mA 10 nA
±2 mAdc
0.03% of rdg 0.12% of rdg
+ 0.3 µA + 0.4 µA
111 Ω 50 mA 0.1 µA
±20 mAdc
0.03% of rdg 0.12% of rdg
+ 3 µA + 4 µA
11.1 Ω 150 mA 1 µA
±200 mAdc
0.05% of rdg 0.15% of rdg
+ 30 µA + 40 µA
1.1 Ω 500 mA 10 µA
±2 Adc
0.5% of rdg 0.7% of rdg + 0.3 mA + 0.4 mA
0.1 Ω 3 A 0.1 mA
±200 mVdc
0.03% of rdg 0.12% of rdg + 30 mV + 40 mV
1.066 MΩ 100V 10 µV
±2 Vdc
0.03% of rdg 0.12% of rdg
+ 0.3 mV + 0.4 mV
1.066 MΩ 300V 0.1 mV
±20 Vdc
0.03% of rdg 0.12% of rdg
+ 3 mV + 4 mV
1.066 MΩ 300V 1 mV
±300 Vdc
0.05% of rdg 0.15% of rdg + 30 mV + 40 mV
1.066 MΩ 300V 10 mV
100 Ω
0.05% of rdg 0.2% of rdg + 30 MΩ + 40 MΩ
0.175V 30V 0.01 Ω
1000 Ω
0.05% of rdg 0.2% of rdg
+ 0.3 Ω + 0.4 Ω
1.75V 30V 0.1 Ω
10 kΩ
0.05% of rdg 0.2% of rdg
+ 1 Ω + 1.5 Ω
17.5V 30V 1 Ω
DC Inputs
*
After 20 minute warm-up. Accuracy is specified in two ways: Accuracy over an 18 to 28°C and 10 to 75% RH environment; and accuracy over a 0 to 50°C and 0 to 85% RH (non­condensing environment). Accuracy over the 0 to 50°C range includes the temperature coefficient effect of the meter.
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 53.4 (2.1) H x 127 (5) W.
49.5
(1.95)
96.5
(3.80)
v
91.4
(3.60)
44.5
(1.75)
2.5
(0.10)
104.1 (4.10)
44.5
(1.75)
Model No. Price Description DPP-5 $525
1
8 DIN panel punch
Accessory
Loading...