M-43
Digital Panel Meters
For Temperature, Process,
Voltage and Current
The DP63000 Series provides the
user the ultimate in flexibility, from
its complete user programming to
the optional setpoint control and
communication capability. The
DP63000-TC accepts a thermocouple
input. The DP63000-RTD accepts
an RTD input and both provide a
temperature display in Celcius or
Farenheit. The meter also features
minimum and maximum display
capture, display offset, °F or °C
indicator, and programmable
user input. The display can be
toggled either manually or
automatically between the selected
displays. Other models include
process, DC voltage or current input
signal and provides a display in the
desired unit of measure.
DP63000
Starts at
$
125
⻬ Thermocouple Inputs
⻬ RTD Inputs
⻬ Programmable
Temperature Offset
⻬ Selectable °F or °C with
1 or 0.1 Degree Resolution
⻬ 3 Selectable
Process Ranges
⻬ 0 to 10 Vdc, 0 to 20 mA,
0 to 50 mA
⻬ 4 Selectable DC
Voltage Ranges
⻬ 0 to 200 mV, 2 V,
20 V, 200 V
⻬ 4 Selectable DC
Current Ranges
⻬ 200 mA, 2 mA,
20 mA, 200 mA
⻬ LCD, Reflective or
LCD with Green/Red
LED Backlight
⻬ 12.2 mm (0.48") H Digits
⻬ Optional Alarm
Output Modules
⻬ Optional Serial
Communication Modules
(RS232 or RS485)
⻬ Operates from 9 to 28 Vdc
Power Source (85 to
250 Vac Optional Supply)
⻬ Display Color
Change Capability at
Setpoint Output
⻬ NEMA 4X/IP65 Sealed
Front Bezel
⻬ Minimum and Maximum
Display Capture
The DP63000 Series display has
12.2 mm (0.48") H digits. The LCD
model is available in 2 versions,
reflective and red/green backlight.
The backlight version is userselectable for the desired color and
also has variable display intensity.
The capability of the DP63000 can
be easily expanded with the addition
of option modules. Setpoint
capability is field-installable with the
addition of the setpoint output
modules. Serial communications
capability for RS232 or RS485 is
added with a serial option module.
The DP63000 can be powered from
an optional power supply that
attaches directly to the back of a
DP63000. The power supply is
powered from 85 to 250 Vac and
provides up to 400 mA to drive the
unit and sensors.
DP63000B-E, $135,
shown smaller than
actual size.
DP63000A-E, $125,
shown smaller than
actual size.
DP6-COM1, DPS-RLYO2,
$30, shown smaller than
actual size.
M-44
M
Common Specifications
Display: 5-digit LCD, 12.2 mm (0.48") high digits
DP63000A: Reflective LCD with full viewing angle
DP63000B: Transmissive LCD with selectable red or
green LED backlight, viewing angle optimized; display
color change capability with output state when using an
output module
Response Time: 500 ms
Memory: Non-volatile E
2
PROM memory retains all
programming parameters and max/min values when power
is removed
Power: Input voltage range is 9 to 28 Vdc with short circuit
and input polarity protection (for 85 to 250 Vac power
operation, must use a model DP6-MLPS1 or a Class 2 or
SELV-rated power supply)
Normal Mode Rejection: 60 dB 50/60 Hz
Input Current Input Current
@ 9 Vdc @ 9 Vdc
Without With
Model No. Display Color DP6-RLY0 DP6-RLY0
DP63000A –– 10 mA 40 mA
DP63000B Red
(max intensity) 85 mA 115 mA
DP63000B Green
(max intensity) 95 mA 125 mA
Environmental Conditions
Operating Temperature Range for
DP63000A-I: -35 to 75°C (-31 to 167°F)
Operating temperature range depends on
display color and intensity level as per below:
Storage Temperature:
-35 to 85°C (-31 to 185°F)
Operating and Storage Humidity: 0 to 85% max relative
humidity (non-condensing)
Altitude: Up to 2000 meters
Construction: This unit is rated for NEMA 4X/IP65
requirements for indoor use, Installation Category I, Pollution
Degree 2; high-impact plastic case with clear viewing
window; panel gasket and mounting clip included
Weight:100 g (3.2 oz)
Intensity
Level Temperature
1 and 2 -35 to 75°C (-31 to 167°F)
Display 3 -35 to 70°C (-31 to 158°F)
4 -35 to 60°C (-31 to 140°F)
5 -35 to 50°C (-31 to 122°F)
Green 1 and 2 -35 to 75°C (-31 to 167°F)
Display 3 -35 to 65°C (-31 to 149°F)
4 -35 to 50°C (-31 to 122°F)
5 -35 to 35°C (-31 to 95°F)
Thermocouple Inputs
Readout: Thermocouple Input
Resolution: 1 or 0.1°
Scale: °F or °C
Offset Range: -999 to 9999 display units
Isolation: TC+ and TC- terminals are
not electrically isolated from the power supply
or optional comms cards
Maximum Input Voltage: 30 Vdc, TC+ to TC
Maximum Input Voltage TC-: 3 Vdc max with respect
to common
Input Accuracy Accuracy @
Type Range @ 23°C ±°C* -35 to 75°C ±°C*
-200 to 400°C 2.3 5.8
(-328 to 752°F)
-200 to 871°C 2.7 4.9
(-328 to 1600°F)
-200 to 760°C 1.9 4.3
(-328 to 1400°F)
-200 to 1372°C 2.3 5.8
(-328 to 2502°F)
-50 to 1768°C 4.5 15.0
(-58 to 3214°F)
-50 to 1768°C 4.5 15.0
(-58 to 3214°F)
100 to 300°C 9.1 <540°C 42.6 <540°C
(392 to 3308°F) 4.5 >540°C 15.0 >540°C
-200 to 1300°C 2.8 8.1
(-328 to 2372°F)
mV -10.00 to 65.00 0.02 mV 0.08 mV
Red
Display
Green
Display
Accuracy* Accuracy*
Input Type Range (18 to 28°C) (0 to 50°C)
100 Ω Pt
alpha = .00385 -200 to 850°C 0.4°C 1.6°C
100 Ω Pt
alpha = .00392 -200 to 850°C 0.4°C 1.6°C
120 Ω Nickel
alpha = .00672 -80 to 260°C 0.2°C 0.5°C
10 Ω Copper
alpha = .00427 -100 to 260°C 0.4°C 0.9°C
RTD Inputs
Readout: RTD input
Resolution: 1 or 0.1°
Scale: °F or °C
Offset Range: -19999 to 19999 display units
Isolation: Input and EXC terminals are not electrically isolated
from the power supply or optional communications cards
Maximum Input Voltage: 30 Vdc
Type: 2-, 3- or 4-wire
Excitation Current:
100 Ω Range: 165 µA
10 Ω Range: 2.5 mA
Lead Resistance:
100 Ω Range: 10 Ω/lead max
10 Ω Range: 3 Ω/lead max
Balanced Lead Resistance: Automatically compensated
up to maximum per lead
Unbalanced Lead Resistance: Uncompensated
* After 20 minute warm-up. Accuracy is specified in 2 ways: accuracy
@ 23°C and 15 to 75% RH environment, and accuracy over a -35 to
75°C and 0 to 85% RH (non condensing) environment. Accuracy
specified over the -35 to 75°C operating range includes meter
tempco and cold junction tracking effects.
* After 20 minute warm-up. Accuracy is specified in 2 ways: accuracy
at 23°C and 15 to 75% RH environment, and accuracy over a -35 to
75°C and 0 to 85% RH (non condensing) environment. Accuracy
specified over the -35 to 75°C operating range includes meter tempco
effects. The specification includes the A/D conversion errors and
linearization conformity. Total system accuracy is the sum of meter
and probe errors. Accuracy may be improved by field calibrating the
meter readout at the temperature of interest.