Omega Products DP470-RTD-C2 User Manual

1
8 DIN Temperature/Process
Meter/Scanner
With Data Logging and RS232 Communications
DP470-T-C2, $365, shown larger than actual size.
DP470 Series
Starts at
$
365
Single- and Multiple-
Input Models
Thermocouple, RTD, and
Process Input Models
Selectable 0.1/1° Resolution Selectable Digital °C/°F
Temperature Units
Alphanumeric Display
RS232 Communications
Standard
Captures Min
and Max Readings
Free Windows-Based
Software
View all Channel Data,
Alarm Status, and Min/Max Values Simultaneously
Log Real-Time DataCreate Exportable
Data Files
The DP470 Series of single- and multiple-input digital temperature and process indicators sets a standard for performance, features, value, and reliability. With built-in digital programmability, communications, and powerful Windows-based software, the DP470 is ideal for monitoring,
1
8 DIN
testing, and process-control applications. Complete configuration of the instrument can be quickly performed from the front panel, including designating sensor input type, sampling rate, limit settings, and resolution. Display of process and min/max values is also user selectable from the front panel. The standard single-input model features easy-to-use front-panel configuration and display of temperature or process measurement with either
0.1 or 1° resolution, min/max values, and limit conditions.
Windows-Based RS232 Communications Software
The DP470 is far more than a stand-alone, high-performance digital temperature or process indicator. Thanks to the exclusive DP470 software, the DP470 is a powerful real-time data monitoring, control, and data logging system. Clear, menu-driven displays guide the user through instrument setup and allow the monitoring, collection, and logging of data remotely through a PC serial port. Software alarms, channel ID, and min/max values are presented, along with a simulated LED display of the selected channel, in an on-screen control panel format. In addition, data can be exported as text to create graphs and print hard-copy reports. (No Protocol is
available).
M-81
Multiple Inputs
With the multiple-input model installed, the DP470 Series can monitor up to 6 thermocouple or process inputs or 3 RTD channels. On single-input models, an optional board can be installed. This board provides enhanced alarm functions as well as a scalable 4 to 20 mA/0 to 10V analog output.
All active inputs can be manually selected or automatically scanned. A front-panel channel indicator accompanies the displayed data. Individual limits can be assigned to each channel. A built-in 5 A rated form “C” relay is energized whenever the limit on the selected channel is exceeded.
Dual Alarms
With the dual-alarm model, the DP470 can be configured to perform on/off control functions as well as process monitoring. Setpoints can be set for high, low, or deviation. In addition, hysteresis (deadband) and delay can be programmed into each setpoint. Alarm conditions can be programmed for manual acknowledgment or for automatic reset. The dual-alarm option comes equipped with two 5 A rated form “C” (SPDT) relays, one for each alarm setpoint. A flashing display alerts the user to an alarm condition.
Panel punches
available, visit
omega.com/
panelpunches
Analog Output Models
Extended Warranty
Program
SM
Analog output capability is also available in combination with the dual alarm option. A linearized output (4 to 20 mA or 0 to 10V) with fully adjustable zero and span allows the instrument to serve as an indicating transmitter, or as a high-level input to a PC-based converter or other recording device.
Specifications
Power: 100 to 240 Vac (±10%),
50 to 400 Hz Display: 4-digit, 14-segment red
14.2 mm H (0.56") LED, 10 mm (0.4") green °C/°F LED, option 10 mm (0.4") green
Accuracy:
1° Resolution:
J, K, T, E: ±1°C/F + 0.03% rdg R, S: ±1°C/F + 0.05% rdg 2-, 3-, 4-Wire RTD:
±0.8°C/F + 0.03% rdg
0.1° Resolution: J, K, T, E: ±0.5°C (0.9°F) ±1 digit 2-, 3-, 4-Wire RTD:
±0.5°C/0.9°F ±1 digit
Process: 0.02% rdg ±1 count
Multi-Input Option Accuracy:
Add ±0.5°C/0.9°F to instrument accuracy specification
Repeatability: ±1 count Temperature Stability:
Zero: 1 µV/°C Span: 0.01%
Thermocouple Reference Junction:
Internal, automatic, 0.03°C/°C, 5 to 45°C (41 to 113°F) Break Detection: Up-scale 50 nA, unit displays OL
Environmental Ranges:
Operating Temperature:
0 to 50°C (32 to 122°F)
Storage Temperature:
-40 to 65°C (-40 to 149°F)
Humidity:
<80% RH, non-condensing
Stability with Time: 0.8° per year Noise Rejection: NMRR 60 dB @
50/60 Hz, CMRR 120 dB @ 50/60 Hz (±0.1 Hz with 250 unbalanced)
Overload Protection: Power Leads to Ground:
1500 Vdc or Vac rms
Across Inputs, for 1 Minute:
Inputs up to 250 Vac/dc
Input Impedance:
Thermocouple: 20 M, exclusive of
break detect current effects
RTD: 16.9 k Process:
Voltage, 1 M; current, 5
Point Update Rate: 2/s nominal (1° readings); 1/s nominal (0.1° readings)
Alarm Relay Contact Rating:
5 A @ 120 Vac SPDT (non-inductive load) form “C”
Multiple-input viewer monitors channels, alarm conditions
and data logging functions.
RS232 Serial Communications:
Full-duplex voltage, isolated from ground to 500 Vac; 9600 baud, 8 bits, 1 stop bit, no parity, ASCII, (No Protocol is available).
Options/Accessories Dual Alarm Model: Two 5 A/120V,
form “C” relay outputs Analog Output Model: 0 to 10 Vdc, fully scalable (load current 2 mA max); 4 to 20 mA DC, fully scalable (load resistance 300 max)
Analog Output Accuracy:
0.25% FS of display value
Analog Output Resolution:
Approximately 0.0125 FS
Analog Output Isolation:
Isolated between input and internal circuit to 500 Vac Multiple-Input Option: Up to 6 thermocouple/process inputs or three 3- or 4-wire RTDs; auto/manual scanning; LED channel indicator, 10 mm (0.4") green; individually programmable setpoints on each input; 5 A/120V, form “C” relay (SPDT) output energized whenever limit exceeded on any channel
Size: 48 x 96 mm (1.89 x 3.78") Panel Cutout:
1
8 DIN,
45 x 92 mm (1.8 x 3.6") Weight: 454 g (1 lb)
OMEGACARESMextended warranty program is available for models shown on this page. OMEGACARESMcovers parts, labor, and equivalent loaners. Ask your sales representative for full details when placing an order.
M-82