DP41-B-EI
Ethernet Server Option
®
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
!
This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as the guide contains important information relating to safety and EMC.
®
®
OMEGAnet® On-Line Service
www.omega.com
Internet e-mail
info@omega.com
Servicing North America:
USA: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford CT 06907-0047
 TEL: (203) 359-1660 FAX: (203) 359-7700  e-mail: info@omega.com
Canada: 976 Bergar  Laval (Quebec) H7L 5A1  TEL: (514) 856-6928 FAX: (514) 856-6886  e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
 Customer Service: 1-800-622-2378 / 1-800-622-BEST  Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
Mexico and TEL: (001)800-TC-OMEGA® FAX: (001) 203-359-7807 Latin American: En Espa
 e-mail: espanol@omega.com
ñol: (001) 203-359-7803
®
®
®
Servicing Europe:
Czech Republic: Frystatska 184, 733 01 Karviná
 TEL: +420 59 6311899 FAX: +420 59 6311114  e-mail: info@omegashop.cz
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany  TEL: +49 7056 9398-0 FAX: +49 7056 9398-29  Toll Free in Germany: 0800 639 7678  e-mail: info@omega.de
United Kingdom: One Omega Drive
ISO 9002 Certified River Bend Technology Centre
 Northbank, Irlam Manchester M44 5BD United Kingdom  TEL: +44 161 777 6611 FAX: +44 161 777 6622  Toll Free in England: 0800 488 488  e-mail: sales@omega.co.uk
TABLE OF CONTENTS
Part 1: Introduction
1.1 Safety and EMC Considerations........................................................................2
1.2 Description ..........................................................................................................3
Part 2: Hardware
2.1 Physical Characteristics and Mounting ...........................................................4
2.2 Rear Panel of Meter with Embedded Ethernet Server .....................................4
2.3 DIP Switches on the iServer...............................................................................5
2.4 Network Communication Interfaces .................................................................6
2.4.1 10Base-T RJ-45 Pinout.........................................................................6
2.4.2 10Base-T Crossover Wiring.................................................................6
Part 3: Network Configuration
3.1 Network Protocols .............................................................................................7
3.2 Ethernet (MAC) Address ....................................................................................7
3.3 DHCP ...............................................................................................................8
3.4 DNS ...............................................................................................................8
3.5 IP Address ...........................................................................................................9
3.5.1 Default IP Address................................................................................9
3.6 Port Number ........................................................................................................9
Part 4: Operations
4.1 Serial Interface Configuration-Communication Protocol..............................10
4.2 Command Structure..........................................................................................10
4.3 Command Formats ...........................................................................................10
4.4 Operations .........................................................................................................12
4.5 Setup and Operation using a Web Browser ..................................................12
4.5.1 Read Devices .....................................................................................14
4.5.1.1 Device Setpoints ................................................................................14
4.5.2 Send Raw Command ..........................................................................14
4.5.3 Device Setup .......................................................................................15
4.5.3.1 Modify Device Parameters (or Device List Entry)............................15
4.5.4 Configuration ......................................................................................16
4.5.5 Access Control ..................................................................................19
4.6 Setting a New IP Address over the Network ..................................................21
4.7 Terminal Server Function ................................................................................22
4.8 Terminal Emulation...........................................................................................23
4.9 Telnet Setup ......................................................................................................24
4.10 HTTPGET Program............................................................................................26
4.11 ARP Protocol .....................................................................................................27
4.12 Remote Access (Tunneling) .............................................................................28
4.12.1 Remote iServer ..................................................................................29
4.12.2 Local iServer ......................................................................................30
4.13 Mail Notifier Software .......................................................................................31
4.13.1 Installation...........................................................................................31
4.13.2 Program Options Setup and Configuration ....................................32
4.13.3 Device Setting Setup and Configuration ..........................................33
Part 5: Specifications .................................................................................................................. 34
Part 6: Factory Preset Values ......................................................................................................35
Appendix A Glossary.............................................................................................................36
Appendix B IP Address ........................................................................................................37
Appendix C IP Netmask.........................................................................................................38
Appendix D ASCII Chart .......................................................................................................39
ASCII Chart Control Codes .............................................................................40
Part 7: Approvals Information
7.1 Electromagnetic Compatibility (EMC) ............................................................41
7.2 FCC ..............................................................................................................41
i
LIST OF FIGURES:
Figure 1.1 iServer on the Ethernet Network.................................................................3
Figure 2.1 Rear Panel View of Meter with Embedded Ethernet Server .....................4
Figure 2.2 DIP Switches on the iServer........................................................................5
Figure 2.3 Option Card Installation...............................................................................5
Figure 2.4 RJ45 Pinout ..................................................................................................6
Figure 2.5 10Base-T Crossover Cable Wiring .............................................................6
Figure 3.1 Labeling ........................................................................................................7
Figure 3.2 DIP Switch on the iServer ...........................................................................8
Figure 4.1 Pinging eis03ec MS-DOS Prompt ............................................................12
Figure 4.2 Device Type ............................................................................................... 13
Figure 4.3 iServer Home Page Menu .........................................................................13
Figure 4.4 Login and Administrator Password .........................................................13
Figure 4.5 Read Devices ............................................................................................ 14
Figure 4.6 Device Setpoints ...................................................................................... 14
FIgure 4.7 Serial Device Query .................................................................................. 14
Figure 4.8 Device Setup ............................................................................................. 15
Figure 4.9 Modify Device Parameters ....................................................................... 15
Figure 4.10 Configuration ............................................................................................ 16
Figure 4.11 Access Control ......................................................................................... 19
Figure 4.12 Access Control .........................................................................................21
Figure 4.13 Terminal Server Configuration .................................................................22
Figure 4.14 Terminal Emulation ....................................................................................23
Figure 4.15 Tera Term Telnet Connection Screen ......................................................24
Figure 4.16 Telnet Setup Menu - iServer Configuration Page ...................................24
Figure 4.17 Telnet Setup Menu - iServer Help Page ...................................................25
Figure 4.18 ARP Commands and Responses .............................................................27
Figure 4.19 PC-to-Device Communication...................................................................28
Figure 4.20 Device-to-Device Communication ............................................................28
Figure 4.21 Configuration Menu - Remote iServer......................................................29
Figure 4.22 Configuration Menu - Local iServer..........................................................30
Figure 4.23 iServer Mail Notifier Main Window............................................................31
Figure 4.24 iServer Mail Notifier Profile Setup ............................................................32
Figure 4.25 iServer Mail Notifier Device Setting .........................................................33
LIST OF TABLES:
Table 2.1 Rear Panel Annunciators ............................................................................5
Table 4.1 Command Prefix Letters ...........................................................................10
Table 4.2 Command Formats ....................................................................................10
ii
NOTES, WARNINGS and CAUTIONS
Information that is especially important to note is identified by following labels:
• NOTE
• WARNING or CAUTION
• IMPORTANT
• TIP
NOTE: Provides you with information that is important to successfully
setup and use the iServer.
CAUTION or WARNING: Tells you about the risk of electrical shock.
CAUTION, WARNING or IMPORTANT: Tells you of circumstances or
practices that can effect the instrument’s functionality and must refer to accompanying documents.
TIP: Provides you helpful hints.
Before You Begin
Inspecting Your Shipment:
Remove the packing slip and verify that you have received everything listed. Inspect the container and equipment for signs of damage as soon as you receive the shipment. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. The carrier will not honor damage claims unless all shipping material is saved for inspection. After examining and removing the contents, save the packing material and carton in the event reshipment is necessary.
Customer Service:
If you need assistance, please contact the Customer Service Department nearest you.
Manuals, Software:
The latest Operation Manual as well as free configuration software and iServer Mail Notifier are available at the website listed on the cover page of this manual or on the CD-ROM enclosed with your shipment.
1
PART 1
INTRODUCTION
1.1 Safety and EMC Considerations
This device is marked with the international caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility).
This instrument is a panel mount device protected in accordance with EN 61010­1:2001, electrical safety requirements for electrical equipment for measurement, control and laboratory. Installation of this instrument should be done by qualified personnel. In order to ensure safe operation, the following instructions should be followed.
This instrument has no power-on switch. An external switch or circuit-breaker shall be included in the building installation as a disconnecting device. It shall be marked to indicate this function, and it shall be in close proximity to the equipment within easy reach of the operator. The switch or circuit-breaker shall meet the relevant requirements of IEC 947–1 and IEC 947-3 (International Electrotechnical Commission). The switch shall not be incorporated in the main supply cord.
Furthermore, to provide protection against excessive energy being drawn from the main supply in case of a fault in the equipment, an overcurrent protection device shall be installed.
Do not exceed voltage rating on the label located on the top of the instrument housing.
Always disconnect power before changing signal and power connections.
Do not use this instrument on a work bench without its case for safety reasons.
Do not operate this instrument in flammable or explosive atmospheres.
Do not expose this instrument to rain or moisture.
Unit mounting should allow for adequate ventilation to ensure instrument does not exceed operating temperature rating.
Use electrical wires with adequate size to handle mechanical strain and power requirements. Install without exposing bare wire outside the connector to minimize electrical shock hazards.
EMC Considerations
Whenever EMC is an issue, always use shielded cables.
Never run signal and power wires in the same conduit.
Use signal wire connections with twisted-pair cables.
Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems persist.
Failure to follow all instructions and warnings may result in injury!
2
1.2 Description
This iServer is designed to connect industrial devices with serial interfaces to the Ethernet network using the TCP/IP protocol. It contains an Ethernet Server interface.
The standard features include:
• Use standard Web Browser (TCP/IP protocol), HTTPGET DOS program or Telnet Simulation, for network connectivity.
• Use a standard home page or customize web page for OEM applications.
For this Ethernet Option, the Communication Menu is only used for internal interface with the Ethernet Option. There is no RS-232 or RS-485 for the user to access. The setting in the Communication Menu should be: 9600 baud rate, 1 stop bit, odd parity and RS-232. For the server side, the settings would be the same.
The following example illustrates how you can hookup the devices with serial interface on the net using the iServer:
Figure 1.1 iServer on the Ethernet Network
TX RX RTN
COMMUNICATIONS
ETHERNET
DC POWER IN
RX TX ON COL
RESET
+ - N/C
Meters and
3
4
PART 2
HARDWARE
2.1 Physical Characteristics and Mounting
For physical dimensions and installation instructions reference the Quickstart and Operator’s Manual .
2.2 Rear Panel of Meter with Embedded Ethernet Server
Figure 2.1 Rear Panel View of Meter
with Embedded Ethernet Server
Table 2.1 Rear Panel Annunciators
Network Communication Interface Section:
ETHERNET RJ45 interface for 10BASE-T connection.
RESET Button: Used for power reseting the iServer.
COL LED (Red) Blinking: Indicates network activities (receiving or sending packets).
ON LED (Green) Solid: Indicates good network link.
1
11
11
P9
P6 P7 P18A P18B
COL
P1
1
ON
J4
1
P5
ETHERNET
119
P2
RESET
1
P3
1
5
2.3 DIP Switches on the iServer
For Dipswitch access you must remove the main board from the case. Refer to the Disassembly Instructions in your Quickstart or Operator’s Manual.
Figure 2.2 DIP Switches on the iServer
Figure 2.3 Option Card Installation
SIGNAL INPUT BD
AC POWER BD
ETHERNET BD
J10
J11
J12
P11
11
4
1A
4
11
10
1
SW2
J4
4
ON
1
OFF
P11
The iServer is shipped with all
DIP switches in "OFF" position
1 To change the IP address
from the serial port
2 To change to default factory
settings 3 To enable/disable DHCP 4 To enable/disable Terminal
Server function
6
2.4 Network Communication Interfaces
2.4.1 10Base-T RJ-45 Pinout
The 10BASE-T Ethernet network (RJ-45) system is used in the iServer for network connectivity. The 10 Mbps twisted-pair Ethernet system operates over two pairs of wires. One pair is used for receiving data signals and the other pair is used for transmitting data signals. This means that four pins of the eight-pin connector are used.
Figure 2.4 RJ45 Pinout
2.4.2 10Base-T Crossover Wiring
When connecting the iServer directly to the computer, the transmit data pins of the computer should be wired to the receive data pins of the iServer, and vice versa. The 10Base-T crossover cable with pin connection assignments are shown on Figure 2.5.
Figure 2.5 10Base-T Crossover Cable Wiring
Use straight through cable for connecting the iServer to an Ethernet hub. The ports on the hub are already crossed.
Pin Name Description
1 +Tx + Transmit Data 2 -Tx - Transmit Data 3 +RX + Receive Data 4 N/C Not Connected 5 N/C Not Connected 6 -Rx - Receive Data 7 N/C Not Connected 8 N/C Not Connected
COL
ON
1
8
7
PART 3
NETWORK CONFIGURATION
3.1 Network Protocols
The iServer can be connected to the network using standard TCP/IP protocols. It also supports ARP, HTTP (WEB server), DHCP, DNS and Telnet protocols.
3.2 Ethernet (MAC) Address
MAC (Media Access Control) address is your computer's unique hardware number. When you're connected to the LAN from your computer, a correspondence table relates your IP address to your computer's physical (MAC) address. The MAC address can be found on the label of your device and contains 6 bytes (12 characters) of hexadecimal numbers XX:XX:XX:XX:XX:XX hex
For example: 0A:0C:3D:0B:0A:0B
Remove the small label with the default IP address and there will be room to put your IP address. See Figure 3.1.
Figure 3.1 Labeling
REMOVE DEFAULT IP ADDRESS LABEL AND PUT NEW CUSTOMER'S IP ADDRESS
MICRO-PRO VERSION #
HEX CODE
CASE SIDE
MODEL NO: SERIAL NO: VOLTS: 90 -240V~ FREQ: 50/60 HZ WATTS: 8.5W IP:
#.# #.#
iSERVER VERSION #
192.168.1.200
MAC
00:00:00:00:00:00
8
3.3 DHCP
DHCP, Dynamic Host Configuration Protocol enables individual computers or devices to extract their IP configurations from a server (DHCP server). If the DHCP is enabled on your iServer, as soon as the iServer is connected to the network, there is an exchange of information between DHCP server and the iServer. During this process the IP address, the Gateway address, and the Subnet Mask will be assigned to the iServer by the DHCP server. Note that the DHCP server must be configured correctly to do such assignment.
If fixed or static IP address is desired, the DHCP must be disabled. The iServer is shipped with DHCP disabled (factory default). The DHCP can be enabled by setting the DIP switch # 3 to the “ON” position.
Figure 3.2 DIP Switch on the iServer
3.4 DNS
DNS, Domain Name System enables individual computers and devices to be recognized over a network based on a specific name instead of an IP address. For example, instead of having to use http://192.168.1.200 (IP address), you would use only http://eis03ec or any eight character name stored as Host Name under Access Control menu in the iServer Home Page. The default DNS name for an iServer is "eis" followed by the last four digits of the MAC address of that particular iServer.
1. It is very important to communicate with the network administrator in order to understand the DHCP and its existing configurations on the host server, before enabling the DHCP on the iServer.
2. The iServers are shipped with a default static IP address of
192.168.1.200 and Subnet Mask of 255.255.255.0.
3. On Novell networks or Windows 2000 where the DCHP is an updated function of DNS this feature may be beneficial since a particular name can be assigned eliminating the need for the IP address, as described in Section 3.4.
SW2
4 1
ON OFF
J4
RESET
DIP switch # 3 shown in “ON” position
9
3.5 IP Address
Every active device connected to the TCP/IP network must have a unique IP address. This IP address is used to build a connection to the iServer’s serial port. Every computer using TCP/IP should have a unique 32-bit address. It is divided into two portions, the network ID and the host ID. For instance, every computer on the same network uses the same network ID. At the same time, all of them have a different host ID. For more details about the IP address see Appendix B.
3.5.1 Default IP Address
The iServer is shipped with a default IP address set to 192.168.1.200 and Subnet Mask of 255.255.255.0. If you are going to use a Web browser or Telnet program to access the iServer using its default IP address, make sure that the PC from which you’re establishing the connection has an IP address that is in the same range as the iServer’s IP address (192.168.1.x, where x can be any number from 1 to 254.
Your PC’s IP address cannot be the same as the iServer’s IP address).
You also need to make sure that your PC’s Subnet Mask is 255.255.255.0. This is a good way to access the iServer over the network and make any configuration changes needed. If the factory default address is already in use on your network, use an Ethernet crossover cable between your computer and the iServer and modify the IP address or any other settings within the iServer.
3.6 Port Number
All TCP connections are defined by the IP address and a port number. A port number is an internal address that provides an interface between an application running on your computer and the network through the TCP/IP protocol.
There are three default TCP socket port numbers assigned to the iServer:
1. Port (socket) number 1000 when using HTTPGET program.
2. Port (socket) number 2000 when trying to access your serial device connected to the serial port of the iServer.
3. Port (socket) number 2002 when trying to access the iServer itself for reading or changing the settings. This can be done using Telnet application.
Example: C:\>Telnet 192.168.1.200 2002
PART 4
OPERATIONS
An industrial device with serial interfaces (PLC, CNC controllers, PC, Data Display Devices, etc.) can be connected to the serial port of the Web Server.
4.1 SERIAL INTERFACE CONFIGURATION - Communication Protocol
A data communication protocol defines the rules and structure of messages used by all devices on a network for data exchange. A typical transaction will consist of a request to send from the MASTER followed by the response from one or more SLAVE devices. Either a single (point-to-point) or multi-drop network (multi-point) is possible.
4.2 Command Structure
There are different command types associated with communication between the Ethernet Server and your device shown in Table 4.1, which shows the Command Prefix Letters (Command Classes)
Table 4.1 Command Prefix Letters
COMMAND PREFIX (COMMAND CLASS) MEANING
^AE Special read, Communication parameters P (Put) Write HEX data into RAM W (Write) Write HEX data into EEPROM. G (Get) Read HEX data from RAM R (Read) Read HEX data from EEPROM U Read status byte V Read measurement data string in decimal format X Read measurement data values in decimal format D Disable E Enable Z Reset
4.3 Command Formats
Table 4.2 shows the command formats for the Ethernet Server.
Table 4.2 Command Formats
For "P" and "W" Command For "G" and "R" Command For "X", "V", "U", "D", "E", classes: classes: & "Z" Command classes: Point-to-point mode Point-to-point mode Point-to-point mode
* ccc<data><cr> * ccc <cr> * ccc <cr>
Multi-point mode Multi-point mode Multi-point mode
* nnccc [<data>]<cr> * nnccc <cr> * nnccc <cr>
10
10
Where: "*" is the selected Recognition Character. You may select any ASCII table symbol from
"!" (HEX address "21") to the right-hand brace (HEX "7D") except for the caret "^", "A", "E", which are reserved for bus format request.
"ccc" stands for the hex-ASCII Command Class letter (one of eleven given in Table 4.1), followed by the two hex-ASCII Command Suffix characters identifying the meter data, features, or menu items to which the command is directed.
"<data>" is the string of characters containing the variable information the computer is sending to the meter. These data (whether BCD or binary) are encoded into hex-ASCII character (see Appendix D for binary-hex-ASCII chart), two characters to the byte. Square brackets [indicating optional status] enclose this string, since some commands contain no data.
"<nn>" are the two ASCII characters for the device Bus Address of RS485
communication.
Use values from "00" to hex "C7" (199 decimal).
The following format is used for each byte sent and received through serial port of Ethernet Server:
1. Seven or Eight-bit binary, Hexadecimal (0 ... 9, A ... F)
2. Two hexadecimal characters contained in each eight-bit field of the message
3. 1 start bit; 7 or 8 data bit; 1 Stop Bit; Odd, Even (No Parity) Bit
The figure below shows the bit sequences when a byte is transmitted or received through the Ethernet Server.
LSB MSB
LSB – Least Significant bit MSB – Most Significant bit
Least Significant beat sent first
11
START 1 2 3 4 5 6 7 8 STOP PARITY