Omega Products CT89 Installation Manual

Page 1
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
Extended Warranty
Shop online at
MADE IN
User’s Guide
SM
CT89 SERIES
Temperature Recorder
Page 2
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified
Stamford, CT 06907-0047 Toll-Free: 1-800-826-6342 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec), H7L 5A1 Canada Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico En Español: 001 (203) 359-7803 FAX: 001 (203) 359-7807 Latin America info@omega.com.mx e-mail: espanol@omega.com
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic Toll-Free: 0800-1-66342 TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: info@omegashop.cz
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany Toll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0 FAX: +49 (0) 7056 9398-29 e-mail: info@omega.de
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified
One Omega Drive, River Bend Technology Centre, Northbank Irlam, Manchester M44 5BD United Kingdom Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611 FAX: +44 (0) 161 777-6622 e-mail: sales@omega.co.uk
OMEGAnet®Online Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
Page 3
I
NTRODUCTION
The CT89 is a precision instrument used to monitor and record temperature on a 6” circular paper chart. The CT89 may be carried as a portable instrument or mounted in a fixed location.
The CT89 offers a variety of features to meet any temperature recording require­ments. A combination of three temperature ranges and four chart speeds provide a high degree of flexibility. In addition, the chart rotation may be set for single or continuous turn operation as required by a particular application. To protect the data being recorded the CT89 uses an automatic battery backup to maintain operation during a power outage.
TWO REAR KEYWAY SLOTS
12
FOR WALL MOUNTING
CHANGING PENS
13
19
17
LATCH
PLUG-IN AC
16
ADAPTER
BATTERY HOLDER
FIG. 1
1
Page 4
12
2
3
4
5a
1
7
13
5
6
11
18
8
9
19
10
15
14
16
2
Page 5
CT89 FEATURES AND CONTROLS
1. The 3 DIGIT TEMPERATURE DISPLAY shows temperature of the environment
being monitored. When the batteries are nearly discharged, the display will alternate the display reading and “LO” to advise the operator that the batteries are discharged and the CT89 will shortly cease operation.
NOTE: The battery backup feature of the CT89 is primarily intended for use in
situations where primary power is lost for short periods of up to 48 hours. The CT89 is not intended to be used as a battery powered instrument. If the CT89 is to be stored for an extended period, it is strongly advised to disconnect the battery pack and remove the batteries to avoid damage to the instrument from battery leakage.
2. The TEMPERATURE RANGE SELECTOR allows the user to choose the desired
temperature range for measurement and recording.
3. The CHART SPEED SELECTOR allows the user to select the time of one full
chart revolution. The corresponding chart has to be chosen according to the desired chart speed. Chart part numbers are listed in this manual.
4. The PEN POSITION ADJUSTMENT KNOB allows the user to adjust the position
of the chart pen.
5. The CHART ADVANCE BUTTON allows the operator to set the chart to the cor-
rect time. Press and hold the chart advance button until the desired time lines up with the Time Pointer. The chart is rotated counterclockwise only. CAUTION:
Movement of the Chart Spindle (Item 9) by hand may cause permanent dam­age to the chart mechanism.
5a. The TIME POINTER
6. TEMPERATURE ADJUSTMENT feature allows the user to adjust the reading of
the digital display during periodic calibration. The CT89 has been factory calibrat­ed and requires no adjustment to meet all published specifications.
7. The POWER ON/OFF / CONTINUOUS / SINGLE CHART SELECTOR allows the
user to apply power to the CT89 and to select Continuous or Single Turn for the chart rotation. When power is first applied to the CT89, the display will show “888” to test each segment of the display, and the pen will move to the edge of the chart. The pen will then move to the correct position on the chart. In the Continu­ous switch position, the chart will rotate until power is removed. In the Single Turn switch position, the chart will make one complete revolution and stop. A blinking dot on the display (Item 1) will indicate that the chart has made one complete revolution and stopped. To reset the chart for another revolution place the switch in the Continuous switch position until the blinking dot goes out and then slide the switch back to the Single Turn position. The chart will make one com­plete revolution and stop.
DO NOT move the pen by hand or interrupt the pen movement. Failure to observe
this will cause the pen to read incorrectly and may result in damage to the pen mechanism.
8. The RECORDING PEN contains special ink. The pen has a wrap-around arm
latch which makes the pen replacement “A SNAP!” To replace the pen, gently lift up the PEN ARM, (do not over bend pen arm) release the pen latch by pushing it
3
Page 6
down, and remove the pen; place a new pen on top of the pen arm, align the notches on the pen arm with the notches on the pen latch and close the latch by wrapping it around the pen holder until it is secured. Replace cap on the pen tip when the CT89 is not used to insure long pen life. For pen installation see
Fig. 1.
9. The CHART SPINDLE holds and rotates the chart during the recording opera­tion. DO NOT ROTATE THE SPINDLE BY HAND AS IT MAY DAMAGE THE
INTERNAL MECHANISM.
10. The PAPER CHART is 6 inches in diameter. in a box of 60 charts each. The chart part numbers are listed on the following page.
TO INSTALL A NEW CHART disconnect power from the CT89 by selecting
OFF with the Power / Single/ Continuous Chart Selector. Place pen cap on pen point. Gently lift the pen arm and while holding it remove the old chart. Slide a new chart under the pen holder and the chart holding tabs. Align the chart with the chart spindle. Apply power to the CT89 and rotate the chart by depressing the chart advance button until the time pointer is aligned with the line on the chart representing the right time or day. Remove the pen cap. If desired, adjust the pen position according to the scale you wish to record.
11. The ROTATION POINTER indicates direction of chart rotation.
12. The HANDLE for carrying folds towards the back of the case to be out of the way when CT89 is mounted on the panel or on the wall.
13. The KEYHOLE SLOTS located on the back of the case are provided for wall or panel mounting.
14. The FRONT COMPARTMENT under chart was designed to store the battery holder for battery backup as well as the connection for the adapter box.
15. The REMOTE TEMPERATURE SENSOR is interchangeable. The furnished 4" stainless steel sensor has 15 feet of cable. The temperature sensor is an electronic digital proprietary design for precision and very high interference im­munity. It utilizes the standard RCA connector.
Note:
The 4 inch metal probe tip may be immersed in fluids compatible with 304
stanless steel. The black platic probe sheathing is moisture resistant, but should not be submersed. If moisture is present the sheathing should be
protected or probe failure will occur.
4
Page 7
16. The BATTERY HOLDER is stored in the front compartment for backup batteries.
Use of 8 alkaline “AA” batteries is required for proper operation.
17. The 12VDC PLUG IN WALL ADAPTER provides primary power for the CT89. Alternate sources of 12 Volt power may also be used. This allows use of the CT89
in automotive, marine or other mobile applications.
18. The POWER CONNECTOR is a connection point for the 12VDC wall adapter or
alternate source of 12VDC power.
19. Back Brace for counter top use.
OW TEMPERATURE (CT89) CHART PART NUMBERS
L
CT87C- -40-30F / 24H CT87 - -40-0C / 24H CT87C- -40-30F / 6H CT87C- -40-0C / 6H CT87C- -40-30F / 7D CT87C- - 40-0C / 7D
CT87C- -20-50F / 24H CT87C- -30-10C / 24H CT87C- -20-50F / 6H CT87C- -30-10C / 6H CT87C- -20-50F / 7D CT87C- -30-10C / 7D
CT87C-50-120F / 24H CT87C-10-50C / 24H CT87C-50-120F / 6H CT87C-10-50C / 6H CT87C-50-120F / 7D CT87C-10-50C / 7D
CT87C-LF-MIX CT87C-LC-MIX
SPECIFICATIONS
Temperature Scale Selectable -40°F to +30°F, -20°F to +50°F, (Fahrenheit Model) +50°F to +120°F Temperature Scale Selectable -40°C to 0°C, -30°C to +10°C, (Celsius Model) +10°C to +50°C Chart Speed Selectable 6 Hours, 24 Hours, 7 Days, 31 Day Chart Speed Accuracy +/-1% Chart Diameter 6 Inches Temperature Display 3 Digit LED 0.5" Temperature Accuracy +/-2°F (+/-1°C) Temperature Sensor Stainless steel tip submersible with 15 ft. of
cable Recording Pen Ink Type Power Supply 120 VAC, 50/60 Hz. or 220/240 VAC, 50Hz. Battery Backup 8 Alkaline “AA” cells (Not included) Battery Life 48 Hours Operating Ambient Temperature Range +32°F to +120°F (0°C to +49°C) Relative Humidity 96% maximum Dimensions 9 ¼” x 7 ¼” x 2 ¾” Weight 4 lbs., 7 oz.
CAUTION: The Temperature Recorder should be placed outside the chamber being
monitored. DO NOT PLACE THE RECORDER DIRECTLY IN AREAS OF EXTREME
TEMPERATURES, HIGH HUMIDITY OR HEAVY CHEMICAL CONTENT.
5
Page 8
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY
RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which
the product was PURCHASED,
2. Model and serial number of the product
under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the
COST of the repair,
2. Model and serial number of theproduct, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2011 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
Page 9
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
SM
TEMPERATURE
䡺⻬
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
䡺⻬
Wire: Thermocouple, RTD & Thermistor
䡺⻬
Calibrators & Ice Point References
䡺⻬
Recorders, Controllers & Process Monitors
䡺⻬
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
䡺⻬
Transducers & Strain Gages
䡺⻬
Load Cells & Pressure Gages
䡺⻬
Displacement Transducers
䡺⻬
Instrumentation & Accessories
FLOW/LEVEL
䡺⻬
Rotameters, Gas Mass Flowmeters & Flow Computers
䡺⻬
Air Velocity Indicators
䡺⻬
Turbine/Paddlewheel Systems
䡺⻬
Totalizers & Batch Controllers
pH/CONDUCTIVITY
䡺⻬
pH Electrodes, Testers & Accessories
䡺⻬
Benchtop/Laboratory Meters
䡺⻬
Controllers, Calibrators, Simulators & Pumps
䡺⻬
Industrial pH & Conductivity Equipment
DATA ACQUISITION
䡺⻬
Data Acquisition & Engineering Software
䡺⻬
Communications-Based Acquisition Systems
䡺⻬
Plug-in Cards for Apple, IBM & Compatibles
䡺⻬
Data Logging Systems
䡺⻬
Recorders, Printers & Plotters
HEATERS
䡺⻬
Heating Cable
䡺⻬
Cartridge & Strip Heaters
䡺⻬
Immersion & Band Heaters
䡺⻬
Flexible Heaters
䡺⻬
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
䡺⻬
Metering & Control Instrumentation
䡺⻬
Refractometers
䡺⻬
Pumps & Tubing
䡺⻬
Air, Soil & Water Monitors
䡺⻬
Industrial Water & Wastewater Treatment
䡺⻬
pH, Conductivity & Dissolved Oxygen Instruments
M4927/0510