ENHANCED MODULAR
CONTROLLER
SERIES MASTER
CSMSTR
l Provides Enhanced Features For Data Acquisition
Or Multi-Zone Pid Control Applications
l Webserver Provides Worldwide Access to
Data Logs And Virtual HMI
l Virtual HMI Offers Built-In PC-Based
SCADA Functionality
l Performs Hierarchical Control of Other Modules
in the Modular Controller Series
l Stores Module Configuration Information,
and Automatically Reprograms Replaced Modules
l Extensive Built-In Driver List Allows Easy
Data Mapping to PLCs, PCs, and SCADA Systems
l Independent Serial Ports Provide Virtually
Unlimited Integration Methods
l 10 Base-T/100 Base-Tx Ethernet Connection
Provides Networking Capability
l Supports up to 16 Modular Controller
Series Modules
l Compactflash
®
Slot Allows Process Data to be
Logged Directly to CSV Files
CSMSTRSX
shown smaller
than actual size.
The CSMSTR is programmed with Crimson 2.0 software for Windows®
2000 or later platforms. The software is an easy to use, graphical
interface which provides a means of communication configuration,
as well as commissioning and calibration of new systems.
Automation Controllers and HMI
The Model CSMSTR is a communications and control platform
designed for use with Modular Controller Series slave modules.
The CSMSTR uses a proprietary high speed serial protocol to
communicate, via backplane connection, with up to 16 slave
modules. Through the same connection, the Master also provides
power to the modules.
When powered up, the CSMSTR automatically identifies and
addresses connected slave modules. By storing the configuration
information of all of the modules, the CSMSTR is able to
automatically configure modules if they are replaced.
The Master provides high-speed RS232/422/485 communication
ports and an Ethernet port for connection to PCs, PLCs, and SCADA
systems. An extensive list of master and slave protocol drivers are
available to allow the CSMSTR to share and exchange variable data
with external devices. The 10 Base-T/100 Base-TX Ethernet port can
also be used to connect and share data with other devices at high
speeds. The virtual HMI feature allows you to create and control
an HMI from any networked PC. An onboard CompactFlash slot
provides storage for the Master’s built-in data logger.
The design of the Modular Controller Series high density packaging
and DIN rail mounting saves time and panel space. The controller
snaps easily onto standard top hat (T) profile DIN rail.
SPECIFICATIONS
Power: 24 Vdc ± 10% 400 mA min. (1 module) 3.5 Amps
max. (16 modules + Expansion Card)
Must use Class 2 or SELV rated power supply
Communications:
USB/PG Port: Adheres to USB specification 1.1
(Device only using Type B connection)
Serial Ports: Format and Baud Rates for each port are
individually software programmable up to 115,200 baud
RS232/PG Port: RS232 port via RJ12
COMMS Ports: RS422/485 port via RJ45,
and RS232 port via RJ12
DH485 TXEN: Transmit enable; open collector,
VOH=15 Vcd, VOL=0.5 V @ 25 mA max
Ethernet Port: 10 BASE-T / 100 BASE-TX RJ45 jack is
wired as a NIC (Network Interface Card)
LEDs:
STS: Status LED indicates condition of master
TX/RX: Transmit/Receive LEDs show serial activity
Ethernet: Link and activity LEDs
CF: CompactFlash LED indicates card status
and read/write activity
Memory:
On-Board User Memory: 4MB of non-volatile flash memory
On-Board SDRAM: CSMSTRSX=2MB; CSMSTRGT=8MB
Memory Card: Compactflash type II slot for type I and
type II cards
1
Real-Time Clock: Typical accuracy is less
than one minute per month drift. Crimson
2.0’s SNTP facility allows synchronization
with external servers
Battery: Lithium coin cell (included).
Typical lifetime of 10 years at 25°C (77°F) A
“battery low” system variable is available
so that the programmer can choose
specific action(s) to occur when the
battery voltage drops below its nominal
voltage.
Environmental Conditions:
Operating Temperature Range:
0 to 50°C (32 to 122°F)
Storage Temperature Range:
-30 to 70°C (-22 to 158°F)
Operating and Storage Humidity:
80% max relative humidity,
non-condensing, from 0 to 50°C
(32 to 122°F)
Vibration According to IEC 68-2-6:
5 to 150 Hz, in X, Y, Z direction for
1.5 hours, 2 g’s
Shock According to IEC 68-2-27:
Operational 25 g, 11 msec in 3 directions
Altitude: Up to 2000 meters
Construction: Case body is burgundy
high impact plastic and stainless steel.
Installation category I, pollution degree 2
Power Connection: Removable wire
clamp screw terminal block
Wire Gage Capacity: 24 AWG to 12 AWG
Torque: 4.45 to 5.34 in/lb (0.5 to 0.6 N-m)
Mounting: Snaps onto standard DIN style
top hat (T) profile mounting rails according
to EN50022 -35 x 7.5 and -35 x 15
Certifications and Compliances:
Safety: UL Listed, File #E302106,
UL508, CSA 22.2 No. 14-M05 Listed
by Und. Lab. Inc. to U.S. and Canadian
safety standards
IEC 61010-1, EN 61010-1: Safety
requirements for electrical equipment
for measurement, control, and
laboratory use, part 1
Electromagnetic Compatability:
Emissions and Immunity to EN 61326:
Electrical equipment for measurement,
control and laboratory use
Immunity to Industrial Locations*:
Electrostatic discharge EN 61000-4-2
Criterion A2; 4 kV contact discharge; 8
kV air discharge; Electromagnetic RF
fields EN 61000-4-3 criterion A 10 V/m;
Fast transients (burst) EN 61000-4-4
Criterion A; 2 kV power; 2 kV signal;
Surge EN 61000-4-5 Criterion A; 1kV
L-L,2 kV L&N-E power; RF conducted
interference EN 61000-4-6 Criterion A;
3 V/rms
Emissions: Emissions EN 55011 class A
Weight: 456.4 g (15.1 oz)
*Notes:
1. Criterion A: Normal operation within specified limits.
2. This device was designed for installation in an enclosure. To avoid electrostatic discharge to the unit in environments with static levels above
4 kV, precautions should be taken when the device is mounted outside an enclosure. When working in an enclosure (ex. making adjustments,
setting jumpers etc.), typical anti-static precautions should be observed before touching the unit.
To Order Visit omega.com/csmstr for Pricing and Details
MODEL NO. MASTER MODULE DESCRIPTION
CSMSTRSX Modular controller master with multiple protocol converter,
CSMSTRGT Modular controller master with multiple protocol conversion,
SFCRM2MC Modular controller crimson programming software,
ACCESSORIES
MODEL NO. DESCRIPTION
G3CF064M 64 MB compact flash card
G3CF256M 256 MB compact flash card
G3CF512M 512 MB compact flash card
CBLPROG0 Programming cable for CS, G3, and paradigm
CBLUSB00 USB programming cable for G3, DSP and modular
PSDR0100 Mini power supply 1A
PSDR0200 Mini power supply 2A
PSDR0400 Mini power supply 4A
RSRSTP00 Rail stops (qty 2)
CSTERM00 Replacement termination plug
CSBASE00 Replacement base
CSTERM00 Replacement termination plug
MODULES
MODEL NO. MODULE DESCRIPTION
CSDIO14R 8-inputs 6 relay outputs
CSDIO14S 8-inputs 6 solid state outputs
CSINV800 8-channel ±10 V input module
CSINI800 8-channel 0(4) to 20 mA input module
CSOUT400 4-channel analog output
CSPID1R0 Single loop module, relay outputs
CSPID1RA Single loop module, relay outputs, analog output
CSPID1RM Single loop module, relay outputs, heater current input
CSPID1S0 Single loop module, solid state outputs
CSPID1SA Single loop module, solid state out. Analog output
CSPID1SM Single loop module, solid state, heater current input
CSPID1TA Single loop module, triac outputs, analog output
CSPID2R0 Dual loop module, relay outputs
CSPID2RM Dual loop module, relay outputs, heater current input
CSPID2S0 Dual loop module, solid state outputs
CSPID2SM Dual loop module, solid state outputs, heater current input
CSPID2T0 Dual loop module, triac outputs
CSPID2TM Dual loop module, triac outputs, heater current input
CSRTD600 6-channel input, RTD
CSSG10RA Single loop, 1 strain gage input, relay outputs, analog out
CSSG10SA Single loop, 1 strain gage input, solid state out, analog out
CSSG11RA Single loop, 2 strain gage input, relay outputs, analog out
CSSG11SA Single loop, 2 strain gage input, solid state out, analog out
CSTC8000 8-channel thermocouple module
Comes complete with termination plug, terminal power block, lithium cell battery, and
operator’s manual.
Ordering Example: CSMSTRSX, controller, SFCRM2MC, software, G3CF512M, 512 MB
flash card, PSDR0100, power supply, CSDIO14R, module.
data logger, web server , virtual HMI up to QVGA (320X240)
size and expansion slot.
data logger, web server, full VGA virtual HMI (640X480)
size and expansion slot with increased DRAM
manual and download cable
(industrial grade 2 million write cycles)
(industrial grade 2 million write cycles)
(industrial grade 2 million write cycles)
controller, type A-B
2