FREQUENCY CALIBRATOR
WITH TOTALIZER
CL535
$
1050
Standard
Read and Source
Frequency Signals
Full 5-Digit Display
Source Sine and
Square Waves
Calibrate Totalizers
CL535, $1050,
shown actual size.
The Omega CL535 is an excellent
tool for calibration, test, and
diagnostics of instruments that
use frequency signals. Instruments
include tachometers, frequency
counters, integrators, and any other
frequency devices in the shop, plant
and/or field. The CL535 brings all
the features you would expect
from a frequency calibrator and
timesaving new ones with the easy
dial knob and easy check switch,
saving hours of troubleshooting
time. The CL535 comes with an
LED indicator showing gate time
for easy trigger level adjustment.
When calibrating a totalizer, the
CL535 eliminates the need of a
stop watch. The calibrator will
automatically stop when the
selected number of pulses has
been sent to the totalizer.
Features
Frequency Read
and Source Functions:
Accuracy ± 0.005% of range
Source and read
Six ranges 1 count per hour
to 20.000Khz
Calibrate totalizer input and
outputs from 1 to 99999
Count pulses 1 to 99999
LED indicator for gate time
Read Function
Read a wide range of
frequencies and waveforms
Read 50 mV to 120 V peak
Read signals from flowmeter
pickups, velocity and
motion detectors
Totalizers
Source Function
Sine and square waves, zero
based and zero crossing
Frequency from 1 CPH to 20 KHz
Adjustable amplitude from
100 mV to 12 volts peak-to-peak
Simulates vibration pickups,
variable speed drives and more
Calibrate Totalizers
Output a number of pulses from
1 to 100 minutes
Gate Trigger Indicator
The LED flashes in synch with
the output frequency. This
allows easy adjustment of the
attenuation for proper gate
triggering
Full 5-Digit Display
True ±0.005% of range accuracy
Bar graph for quick reference of
trigger level and output
levels, 5% of frequency range
High contrast graphic display
viewable in all lighting
conditions and angles
D-117
FREQUENCY CALIBRATOR WITH TOTALIZER
Extended Warranty
Program
SM
Waveforms Source Specifications:
Easy Dial Knob
Change the speed of dialing
your test point by just pushing
down on the knob
Easy Check Switch
Stop watch style push button for
accurate totalizer measurements
and for high and low readings
Uses a Standard
9V Alkaline Battery
Superior battery life of 24 hours
under typical continuous usage
Easy access to battery
compartment
240 Vac Tolerant
Fuse-less protection from
accidental misuse
Lightweight and Rugged
with a Solid Feel
Convenient Velcro®hand strap
allows for a firm confident grip or
attachment to pipes and ladders
General Specifications
(Unless otherwise indicated all
specifications are rated from a
nominal 23°C, 70% RH for 1 year
from calibration)
Common Specifications for all
Frequency Modes:
Frequency Ranges:
1 CPH to 20.000 kHz
Accuracy: ± 0.005% of range
Temperature Effect:
= 10 ppm/°C of range
Frequency Ranges Specifications:
1: 1 CPH< CPH range < 20000 CPH
2: 0.1 CPM (0.0167Hz) < CPM
range < 2000.0 CPM (33.33 Hz)
3: 0.01 Hz < Hz < 200.00 Hz
4: 0.1 Hz < Hz range < 2000.0 Hz
5: 0.001 kHz < kHz range
< 20.000 kHz
6: Totalize inputs/outputs from
1 to 99999 counts in 0.1 minutes
to 100.0 minutes
Read Inputs Specifications:
Read x1 Attenuation Range:
0.1 V pk to 12 V pk
x10 Attenuation Range:
1 V pk to 120 V peak - limit of
attenuation is 120 V pk
Input Impedance:
> 1 Meg + 100 pF
Adjustable Signal: Attenuation
adjustable trigger level with X1
and x10 attenuation ranges
Miscellaneous Battery Life:
24-hour typical
Fuse- Less Protection:
240 Vrms
Output Current: > 6 mA pp
at 12 V pp output, 20 kHz
utput Impedance: < 25
O
Square Wave: Zero Crossing,
zero based selectable
Rise/Fall Time: < 0.0001% of
output Vpk per second
Frequency Jitter: < 0.5LSB of
frequency range
Duty Cycle: 50% ± 2%
Sine Wave:
Offset and Zero Crossing
Symmetry: <± 10% of V pk
output amplitude setting
Amplitude Adjustment:
100 mV < nominal output
< 12 V pp ± 10% of setting
Operating Temperature Range:
-20 to 60°C (-5 to 140°F)
Storage Temperature Range:
-30 to 60°C (-22 to 140°F)
Relative Humidity Range:
10%<RH<90% (0 to 35°C),
non-condensing 10%<RH<70%
(35 to 60°C), non-condensing
Display: High contrast graphic liquid
crystal display with 11.4 mm (0.45")
high digits
Battery: 9V alkaline, low battery
indication with nominal 1-hour of
operation left (included)
Over-Voltage Protection:
To 120 Vrms (rated for 30 seconds) or
240 Vrms (rated for 15 seconds)
Connection: Test leads attached, with
alligator clips
Dimensions:
177.8 H x 83.8 W x 56.1 mm D
(7.00 x 3.30 x 2.21")
Weight: 340 g (12.0 oz)
OMEGACARESMextended
warranty program is available for
models shown on this page. Ask
your sales representative for full
details when placing an order.
OMEGACARE
labor and equivalent loaners.
SM
covers parts,
To Order (Specify Model Number)
MODEL NO. PRICE DESCRIPTION
CL535 $1050 Frequency calibrator with totalizer
SC-530 65 Rugged carrying case
Comes complete with NIST-traceable certificate, 9V battery and operator’s manual.
Ordering Example: CL535, frequency calibrator with totalizer, $1050.
OCW-2, OMEGACARESMextends standard 3-year warranty to a total of 5 years ($262),
$1050 + 262 = $1312.
Recommended Reference Book: Marks’ Standard Handbook
for Mechanical Engineers,
See Section Y for Additional Books
D-118
INSTRUMENTATION
D
CL535, $1050, shown
smaller than actual size.
AVAILABLE FOR FAST DELIVERY!
ME-0301, $200.