Omega Products CL535 User Manual

FREQUENCY CALIBRATOR WITH TOTALIZER
CL535
$
1050
Standard
Read and Source
Frequency Signals
Full 5-Digit DisplaySource Sine and
Square Waves
Calibrate Totalizers
CL535, $1050, shown actual size.
The Omega CL535 is an excellent tool for calibration, test, and diagnostics of instruments that use frequency signals. Instruments include tachometers, frequency counters, integrators, and any other frequency devices in the shop, plant and/or field. The CL535 brings all the features you would expect from a frequency calibrator and timesaving new ones with the easy dial knob and easy check switch, saving hours of troubleshooting time. The CL535 comes with an LED indicator showing gate time for easy trigger level adjustment. When calibrating a totalizer, the CL535 eliminates the need of a stop watch. The calibrator will automatically stop when the selected number of pulses has been sent to the totalizer.
Features
Frequency Read and Source Functions:
Accuracy ± 0.005% of rangeSource and readSix ranges 1 count per hour
to 20.000Khz
Calibrate totalizer input and
outputs from 1 to 99999
Count pulses 1 to 99999LED indicator for gate time
Read Function
Read a wide range of
frequencies and waveforms
Read 50 mV to 120 V peakRead signals from flowmeter
pickups, velocity and motion detectors
Source Function
Sine and square waves, zero
based and zero crossing
Frequency from 1 CPH to 20 KHzAdjustable amplitude from
100 mV to 12 volts peak-to-peak
Simulates vibration pickups,
variable speed drives and more
Calibrate Totalizers
Output a number of pulses from
1 to 100 minutes
Gate Trigger Indicator
The LED flashes in synch with
the output frequency. This allows easy adjustment of the attenuation for proper gate triggering
Full 5-Digit Display
True ±0.005% of range accuracyBar graph for quick reference of
trigger level and output levels, 5% of frequency range
High contrast graphic display
viewable in all lighting conditions and angles
D-117
FREQUENCY CALIBRATOR WITH TOTALIZER
Extended Warranty
Program
SM
Waveforms Source Specifications:
Easy Dial Knob
Change the speed of dialing
your test point by just pushing down on the knob
Easy Check Switch
Stop watch style push button for
accurate totalizer measurements and for high and low readings
Uses a Standard 9V Alkaline Battery
Superior battery life of 24 hours
under typical continuous usage
Easy access to battery
compartment
240 Vac Tolerant
Fuse-less protection from
accidental misuse
Lightweight and Rugged with a Solid Feel
Convenient Velcro®hand strap
allows for a firm confident grip or attachment to pipes and ladders
General Specifications
(Unless otherwise indicated all specifications are rated from a nominal 23°C, 70% RH for 1 year from calibration)
Common Specifications for all Frequency Modes:
Frequency Ranges:
1 CPH to 20.000 kHz
Accuracy: ± 0.005% of range Temperature Effect:
= 10 ppm/°C of range
Frequency Ranges Specifications:
1: 1 CPH< CPH range < 20000 CPH 2: 0.1 CPM (0.0167Hz) < CPM
range < 2000.0 CPM (33.33 Hz)
3: 0.01 Hz < Hz < 200.00 Hz 4: 0.1 Hz < Hz range < 2000.0 Hz 5: 0.001 kHz < kHz range
< 20.000 kHz 6: Totalize inputs/outputs from 1 to 99999 counts in 0.1 minutes to 100.0 minutes
Read Inputs Specifications:
Read x1 Attenuation Range:
0.1 V pk to 12 V pk
x10 Attenuation Range:
1 V pk to 120 V peak - limit of attenuation is 120 V pk
Input Impedance:
> 1 Meg + 100 pF Adjustable Signal: Attenuation adjustable trigger level with X1 and x10 attenuation ranges
Miscellaneous Battery Life:
24-hour typical
Fuse- Less Protection:
240 Vrms
Output Current: > 6 mA pp at 12 V pp output, 20 kHz
utput Impedance: < 25
O
Square Wave: Zero Crossing,
zero based selectable
Rise/Fall Time: < 0.0001% of output Vpk per second Frequency Jitter: < 0.5LSB of frequency range
Duty Cycle: 50% ± 2%
Sine Wave:
Offset and Zero Crossing Symmetry: <± 10% of V pk
output amplitude setting
Amplitude Adjustment:
100 mV < nominal output < 12 V pp ± 10% of setting
Operating Temperature Range:
-20 to 60°C (-5 to 140°F)
Storage Temperature Range:
-30 to 60°C (-22 to 140°F)
Relative Humidity Range:
10%<RH<90% (0 to 35°C), non-condensing 10%<RH<70% (35 to 60°C), non-condensing Display: High contrast graphic liquid crystal display with 11.4 mm (0.45") high digits Battery: 9V alkaline, low battery indication with nominal 1-hour of operation left (included)
Over-Voltage Protection:
To 120 Vrms (rated for 30 seconds) or 240 Vrms (rated for 15 seconds) Connection: Test leads attached, with alligator clips
Dimensions:
177.8 H x 83.8 W x 56.1 mm D (7.00 x 3.30 x 2.21") Weight: 340 g (12.0 oz)
OMEGACARESMextended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARE labor and equivalent loaners.
SM
covers parts,
To Order (Specify Model Number)
MODEL NO. PRICE DESCRIPTION
CL535 $1050 Frequency calibrator with totalizer
SC-530 65 Rugged carrying case
Comes complete with NIST-traceable certificate, 9V battery and operator’s manual.
Ordering Example: CL535, frequency calibrator with totalizer, $1050. OCW-2, OMEGACARESMextends standard 3-year warranty to a total of 5 years ($262),
$1050 + 262 = $1312.
Recommended Reference Book: Marks’ Standard Handbook
for Mechanical Engineers,
See Section Y for Additional Books