Omega Products CL510-1 User Manual

RTD Simulators
Extended Warranty
Program
SM
CL510 Series
Starts at
$
549
Standard
Simulate RTD
Temperature Outputs
High AccuracyWorks with All
Pulsed Instruments and a Wide Variety of Transmitters
Easy Dial Knob Adjusts
Output by 0.1°C/°F for CL510-7 Only, Others 1°C/°F
Easy Check Switch:
User Settable for 0% and 100% Span Adjustments
The OMEGA®CL510 and CL510-7 RTD simulators simulate standard RTD curves over the entire industrial temperature range. Choose between 7 standard RTD curves.
The CL510 Series will simulate RTD resistances into all types of instruments such as transmitters, recorders, controllers, alarms, data acquisition and computer systems. Calibrators are easy to reset and are compatible with pulsed systems and transmitters.
The easy check function allows the user to store 3 output temperatures for real convenience. All settings are saved with the power off.
Specifications
[Unless otherwise indicated, all specifications are rated from a nominal 23°C (73°F), 70% RH for 1 year from calibration] Range: Pt100, -200 to 850°C; Cu10, -200 to 260°C; Ni110,
-100 to 300°C; Ni120, -80 to 260°C Accuracy: ±(0.015% of setting in + 0.05 )
Typical Accuracies for RTD Curves are:
a = 1.3850, 1.3902, 1.3916,
1.3926: ±0.25°C (±0.5°F) Cu10 : ±1.5°C (±3°F) Ni110 , Ni120 :
±0.25°C (±0.5°F)
Allowable Excitation Current:
100 µA to 10.2 mA, steady or pulsed/intermittent/smart
For Accuracies Below 100 µA Add: ±10 µV/excitation
current (units are in )
Pulsed Excitation Current Compatibility: DC to 0.01
second pulse widths Connections: 4 leads (2 red, 2 black), 70 cm (28") with spade lugs
Output Dial Adjustment Resolution: 0.1°C or 0.1°F
adjustment resolution for CL510-7; 1°C or 1°F adjustment resolution for CL510
Temperature Coefficient:
±0.05 /°C ambient
Operating Temperature Range:
-25 to 60°C (-10 to 140°F)
Storage Temperature Range:
-25 to 60°C (-10 to 140°F)
Relative Humidity Range:
10% RH 90% [0 to 35°C (32 to 95°F)], non-condensing; 10% RH 70% [35 to 60°C (95 to 140°F)], non-condensing Battery: 9V alkaline (included) provides 45 hours of continuous use, with low battery indication Display: High-contrast graphic liquid crystal 5-digit display with
9.07 mm H (0.357") digits
Dimensions:
125.5 H x 46.2 W x 80 mm L (4.9 x 1.82 x 3.15") Weight: 255 g (9 oz)
OMEGACARESMextended warranty program
is available for models shown on this page. Ask your sales representative for full details
when placing an order. OMEGACARE
covers parts, labor and equivalent loaners.
SM
CL510 Single RTD curve simulator with 1° resolution and selectable units in °C or °F
CL510-7 multi-type RTD simulator includes 7 RTD curves with 1° resolution and selectable units in °C or °F. Curves included with the CL510-7 are Pt100a =
1.3926 and Cu10, Ni110, Ni120, .
CL510, $549.
Pt 100 - a Codes
1 0.003850 2 0.003902 3 0.003916 4 0.003926
1.3850, 1.3902, 1.3916,
AVAILABLE FOR FAST DELIVERY!
To Order (Specify Model Number)
Model No. Price Description CL510-7 $599 Multi-type RTD simulator (7 RTD curves) CL510-(*) 549 Single RTD curve SC-800 10 Soft carrying case for CL510
Insert one RTD code from chart at left.
*
Comes complete with NIST certification (without test point), operator’s manual and 9V battery. Ordering Example: CL510-7, multi-type RTD simulator with 7 RTD curves, $599. OCW-2,
OMEGACARE $599 + 107 = $706.
SM
extends standard 3-year warranty to a total of 5 years ($107),
K-62
K
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...