Omega RH-USB, USB, IR-USB, PX409-USB, UTC-USB User Manual

...
TM
User’s Guide
IR-USB
RH-USB Probe
TJ-USB Probe
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
www.omegamanual.info
UTC-USB Connector
Probes, Sensors, Connectors, and
USB SERIES
Pressure Transducers
omega.com info@omega.com
Servicing North America:
U.S.A. Omega Engineering, Inc. Headquarters: Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
USB Series Probes, Sensors, Connectors, and Pressure Transducers
Table of Contents
Section ..............................................................................................................Page
Section 1 Introduction ......................................................................................... 1-1
1.1 Precautions ................................................................................................ 1-1
1.2 Safety Warnings and IEC Symbols ........................................................ 1-1
1.3 Statement on CE Marking ....................................................................... 1-2
1.4 General Description .................................................................................. 1-2
Section 2 Hardware ............................................................................................. 2-1
2.1 Package Inspection ................................................................................... 2-1
2.2 Included Items .......................................................................................... 2-1
2.3 IR-USB Accessories ................................................................................... 2-1
2.3.1 IR-USB Accessories Dimensions ................................................... 2-2
2.3.2 Laser Sighting Accessory Operation ............................................. 2-4
Section 3 Software ............................................................................................... 3-1
3.1 Getting Started .......................................................................................... 3-1
3.2 Software Installation Requirements .........................................................3-1
3.3 Software Installation ................................................................................ 3-1
3.4 TRH Central Measurement and Recording Program .......................... 3-6
3.4.1 Main Tab Menu ................................................................................ 3-6
3.4.2 Channel Configuration ................................................................... 3-7
3.5 Chart Tab ................................................................................................... 3-8
3.6 Data Log Tab ........................................................................................... 3-12
Section 4 Specifications ...................................................................................... 4-1
Section 5 Emissivity Table (For IR-USB Models) ......................................... 5-1
i
USB Series Probes, Sensors, Connectors, and Pressure Transducers
Table of Figures
Figure Description Page
Section 1 Introduction
1-1 IEC Symbols ........................................................................................ 1-1
1-2 TJ-USB Overall Dimensions ............................................................. 1-2
1-3 RH-USB Dimensions ......................................................................... 1-2
1-4 UTC-USB Dimensions ....................................................................... 1-3
1-5 PX409-USB Dimensions .................................................................... 1-3
1-6 IR-USB Dimensions ........................................................................... 1-3
Section 2 Hardware
2-1 Mounting Bracket, OS100-MB .......................................................... 2-2
2-2 Water Cooling Jacket, OS100-WC ................................................... 2-3
2-3 Typical Water Cool Jacket Assembly .............................................. 2-3
2-4 Air Purge Collar, OS100-AP .............................................................. 2-3
2-5 Laser Sighting Accessory, OS100-LS ............................................... 2-4
2-6 Laser Warning Label ......................................................................... 2-5
Section 3 Software
3-1 Welcome Screen ................................................................................. 3-1
3-2 Install Options Screen ........................................................................ 3-2
3-3 Select Install Folder Screen ............................................................... 3-2
3-4 License Agreement Screen ................................................................ 3-3
3-5 Confirm Installation Screen .............................................................. 3-3
3-6 Welcome to the Device Driver Installation Wizard Screen ......... 3-4
3-7 Device Driver Installation Wizard Screen ...................................... 3-4
3-8 Completing the Device Driver Installation Wizard Screen ......... 3-5
3-9 Installation Complete Screen ........................................................... 3-5
3-10 Channel Tab Screen ........................................................................... 3-6
3-11 TRH Central Program Screen ........................................................... 3-6
3-12 Channel Configuration Screen .......................................................... 3-7
3-13 Chart TAB Menu Screen ................................................................... 3-8
3-14 Charting Screen .................................................................................. 3-8
3-15 Start Data Logging/Plotting Screen ................................................ 3-9
3-16 Configure Axis Screen ..................................................................... 3-10
3-17 Charting Options Screen ................................................................. 3-10
3-18 Data Log TAB Screen ....................................................................... 3-12
3-19 Data Logging Screen ........................................................................ 3-13
3-20 Start Data Logging/Plotting Screen .............................................. 3-13
Section 4 Specifications
4-1 Optical Field of View ......................................................................... 4-1
ii
Section 1 - Introduction
Please read this manual completely before installing and operating your USB based probe, connector, or pressure transducer.
It’s important to read and follow all notes, cautions, warnings and safety precautions before operating this device.
1.1 Precautions
• This device is not designed for use in medical or nuclear applications.
• Do not operate this device in flammable or explosive environments.
• Do not operate this device outside of the recommended use outlined in
There are no user serviceable parts inside your device. Attempting to repair or service your unit may void your warranty:
this manual.
NOTE:
Introduction
1
1.2 Safety Warnings and IEC Symbols
This device is marked with international safety and hazard symbols in accordance with IEC standards. It is important to read and follow all precautions and instructions in this manual before operating or commissioning this device as it contains important information relating to safety and EMC. Failure to follow all safety precautions may result in injury and or damage to your device. Use of this device in a manner not specified will void your warranty
IEC symbols Description
Caution, refer to accompanying documentation
EU’s Waste Electrical and Electronic
Figure 1-1. IEC Symbols
Equipment Compliance
1-1
1
DIMENSIONS mm (in)
Introduction
1.3 Statement on CE Marking
1.4.1 CE Marking
It is the policy of OMEGA to comply with all worldwide safety and EMI/ EMC regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
1.4 General Description
1.4.1 General Description
TJ-USB: Type-K Thermocouple probes with direct USB connection features a
rugged transition joint construction.
RH-USB: Relative Humidity/Temperature Probe with direct USB connection features a rugged Stainless Steel Housing.
UTC-USB: Patented Universal Thermocouple Connector/Converter with USB output.
PX409-USB: Pressure Transducer with direct USB connection, features a micro­machined silicon sensor and 316L stainless steel wetted parts.
IR-USB: Infrared temperature sensor with direct USB connection.
1.4.2 Overall Dimensions
457.18 (18.0) or 609.6 (24.0) STANDARD
Ø 4.8 (3/16) or Ø 6.4 (1/4)
Figure 1-2. TJ-USB Overall Dimensions
Ø 16 (5/8)
TJ-USB-CASS-316-18-K1
OMEGA.COM
88.9 (3-1/2)
28.8
(1-1/8)
914.4 (36.0)
All models feature an integral 2m (6’) shielded output cable and free user software that converts your PC into a humidity, or temperature or pressure strip chart data logger.
21
(13/16)
DIMENSIONS: mm (in)
46 (1-13/16)
2m (6 ft)
131 (5.18)
Ø 16 (5/16)
1-2
Figure 1-3. RH-USB Dimensions
THERMOCOUPLE CONNECTION
1/4-18NPT PRESSURE
ADAPTER
25.4 (1.00)
MODEL NO:
PRESSURE RA
OUTPUT:
SERIAL NO:
0 TO 5V
1234
PX3
82.5 (3.25)
-
UNIVERSAL
THERMOCOUPLE CONNECTOR
TC
UTC-USB
+
R
omega.com
Figure 1-4. UTC-USB Dimensions
GAGE
VENT
Ø 22.4 (0.88)
OMEGADYNE
R
OM
SU
USB
DIMENSIONS mm (in)
15.88 (0.63)
2 m (6 ft)
Introduction
USB CONNECTION
POWER LED
1
HEX 1.0 AF
HEX 0.87 AF
1/4-18 NPT PRESSURE
ADAPTER
HEX 0.87 AF
1/4-18 NPT PRESSURE
ADAPTER
104.1 (4.1)
7.6 (0.3)
PX 409 USB SERIES PRESSURE RANGES 15 PSIG AND BELOW
MODEL NO:
PRESSURE RA
OUTPUT:
SERIAL NO:
OMEGADYNE
R
0 TO 5V
OM
1234
SU
PX3
104.1 (4.1)
7.6 (0.3)
PX 409 USB SERIES PRESSURE RANGES 30 PSIG TO 1000PSIG.
MODEL NO:
PRESSURE RA
OUTPUT:
SERIAL NO:
OMEGADYNE
R
0 TO 5V
OM
1234
SU
PX3
119.4 (4.7)
7.6 (0.3)
DIMENSIONS mm (in)
PX 409 USB SERIES PRESSURE RANGES ABOVE 1000PSIG.
Figure 1-5. PX409-USB Overall Dimensions
1-3
1
Introduction
3/4-16 UNF-2A
21.1 (0.83)
63.5 (2.5)
25.4 (1.0)
Ø25.4 (1.0)
DIMENSIONS mm (in)
Figure 1-6. IR-USB Dimensions
1-4
Section 2 – Hardware
It is important that you read this manual completely and follow all safety precautions before operating this instrument.
2.1 Package Inspection
Remove the packing list and verify that you have received all your equipment. If you have any questions about the shipment, please call our Customer Service Department at 1-800-622-2378 or 203-359-1660. We can also be reached on the Internet at www.omega.com, e-mail: cservice@omega.com
When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
NOTE:
Hardware
2
2.2 Included Items
The following items are supplied in the box.
• 1 TJ-USB Probe Assembly, or 1 RH-USB Probe Assembly, or 1 UTC-USB Universal Thermocouple Connector, PX409-USB Pressure Transducer Assembly, or IR-USB Infrared Temperature Sensor
• 1 USB cable 6' Long (Model UTC-USB Only)
• Software and manual are downloadable from omega.com
2.3 IR-USB Accessories
The IR-USB is offered with four different accessories:
• Mounting Bracket: for wall mounting of the sensor
• Air Purge Collar: used to keep the surface of the optical clean and safe from smoke, dust, and fumes
• Water Cooling Jacket: for operating in an ambient temperature above 85°C (185°F), for temperatures up to 200°C (392°F)
• Laser Sighting Accessory: for alignment of the sensor head to the target area to make a more precise reading (see Section 2.3.2 for more information)
2-1
2
Hardware
2.3.1 IR-USB Accessories Dimensions
12.7 (0.5)
12.7 (0.5)
25.4 (1)
90
(1/8)
23.3
(.919)
31.8
(1.25)
42.9
(1.69)
3.2
(1/8)
50.0
(1.97)
3.2
Ø 4
(0.156)
Dimensions mm (in.) Ø = Diameter
Figure 2-1. Mounting Bracket, OS100-MB
Ø 19
(0.755)
Dimensions mm (in.)
1/8 NPT COMPRESSION
FITTING , 2 PLCS.
INLET
3/4-16 UNF-2B 3/4-16 UNF
60.3
(2.375)
OUTLET
8
(.312)
41.3 (1.625)
Figure 2-2. Water Cooling Jacket, OS100-WC
2-2
Hardware
4 3 2 1
2
INLET
UP TO 200C (392F) AMBIENT TEMPERATURE
TO MAIN HOUSING
Figure 2-3. Typical Water Cool Jacket Assembly
17.5
(0.69)
28.6 (1.125)
1/16 NPT
3/4-16 UNF 2B
THRU.
Dimensions mm (in.)
COMPRESSION
FITTING
Figure 2-4. Air Purge Collar, OS100-AP
OUTLET
2-3
2
Hardware
2.3.2 Laser Sighting Accessory Operation
The laser sight accessory screws onto the front of the sensor head. This accessory is only used for alignment of the sensor head to the target area. After the alignment process, the accessory has to be removed from the front of the sensor head before temperature measurement.
The laser sight accessory is powered from a small compact battery pack (included with the accessory). Connect the battery pack to the accessory using the cable provided. Aim at the target, and turn on the battery power using the slide switch on the battery pack. Adjust the sensor head position so that the laser beam points to the center of the target area. Turn off the battery pack, and remove the laser sighting accessory from the sensor head. See Fig. 2-5 for reference.
CAUTION:
You may receive harmful laser radiation exposure if you do not adhere to the warnings listed below:
Use of controls or adjustments or performance of procedures other than those specified here may result in hazardous radiation exposure.
• Do not look at the laser beam coming out of the lens or view directly with optical instruments - eye damage can result.
• Use extreme caution when operation the laser sight accessory
• Never point the laser accessory at a person
• Keep out of the reach of all children
WARNING:
Do not attempt to open the laser sight accessory. There are no user serviceable parts inside.
2-4
Loading...
+ 28 hidden pages