INTRODUCTION
The OMEGA®MFT multiconductor feedthroughs are designed for use in applications that require several thermocouple sensors to pass through a wall or a bulkhead at one opening or within a small area. They are manufactured from 416 stainless steel. Their heavy duty construction allows the MFT fittings to be used in high pressure or vacuum applications (when used with stainless steel ferrules).
UNPACKING
Check to see that the following parts are in the package: MFT Housing, Pusher, Lock Pin, Nut, Ferrules, Blind Probes, Operator’s Manual.
Remove the Packing List and verify that you have received all equipment. If you have any questions about the shipment, please call the OMEGA Customer Service Department at 1-800-622-2378 or 203-359-1660. We can also be reached on the Internet at
omega.com e-mail: info@omega.com
When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any claims unless all shipping material is saved for their examination. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
FERRULES
All multiconductor feedthroughs are supplied in standard form with 300 series stainless steel ferrules (necessary in high pressure or vacuum applications). When the nut is tightened, these stainless steel ferrules deform and become permanent. Note that the probe sheath will become nicked as the ferrule forms around it.
If it is required that the probes be removed or replaced several times in the feedthrough, teflon ferrules should be used. Teflon ferrules will not deform the probe sheath, thus allowing the same probe to be re-used.
NOTE
M0152/0103
Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info
2
IMPORTANT NOTE
NEVER re-use ferrules! Once the pusher part of the MFT assembly has pressed
against them, ferrules are deformed in some way (both steel and teflon ferrules).
ALWAYS replace the ferrules when re-using the multiconductor feedthrough.
Replacement part numbers are listed at the end of this manual.
MALE THREADED CAPS
An optional male threaded cap is also available for use when assembling the MFT for certain applications (Figure 2b). They are used INSTEAD of the nut (that is provided) when an external male NPT thread is needed. Using the threaded cap will allow for a conduit pipe to be threaded directly onto the MFT housing.
3
MFT HOUSING MFT HOUSING
STANDARD NUT OPTIONAL MALE
THREADED CAP (FTN)
a. MFT WITH STANDARD NUT
b. MFT WITH OPTIONAL FTN CAP
Figure 2. MFT, Side Views
MFT ASSEMBLY
Step 1.
Assemble the OMEGA Multiconductor Feedthrough and Probes as shown in Figure 1. Ensure that, all parts are clean. Dirt or foreign material in the fitting can cause leaks or failure. Make sure all unused holes are plugged. (Blind probes are provided). Teflon tape should be used on all pipe joints to provide a good seal and to prevent the thread parts from seizing each other on disassembly.
Step 2.
Tighten the nut or male threaded cap finger-tight. Scribe a reference mark on it along the top of the housing and the nut to mark the “zero” position.
From that point, tighten the nut approximately
1
3-turn for all sizes but the 1⁄4"
probes. (See Figure 3).
For the
1
4" probes, tighten the nut approximately 1⁄2 -turn minimum. (See
Figure 3).
4
PRESSURE OR VACUUM APPLICATIONS
If OMEGA feedthroughs are used in pressure or vacuum applications, read and follow the instructions carefully. After proper installation and tightening, bring the system pressure up (or down) slowly while testing for pressure. IF ANY LEAKAGE is detected, return pressure to atmosphere at once and repair or replace fittings. Do not mix or interchange parts of tube fittings made by other manufacturers. Use only OMEGA parts to prevent product failure. Do not attempt to re-use “used” ferrules.
REPLACEMENT PARTS AND OPTIONS
• 300 Series Stainless Steel Ferrules (pkg of 10): OMEGA Part Number: SS-FER-*
• Telfon Ferrules (pkg of 10): OMEGA Part Number: T-FER-* (* Where the star is replaced by the sheath diameter in inches)
• Optional Male Threaded Cap (3 Sizes): OMEGA Part Number: (for
1
4" NPT) FTN-1-14
(for
1
2" NPT) FTN-1-12
(for
3
4" NPT) FTN-1
• Teflon Tape, 1⁄2" by 260": OMEGA Part Number: Teflon Tape
5
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY
RETURNS, please have the following informa-
tion available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for cur­rent repair charges. Have the following information avail­able BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to
the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2009 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or
reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified
Stamford, CT 06907-0047 Toll-Free: 1-800-826-6342 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Canada: Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico: En Español: 001 (203) 359-7803 FAX: (001) 203-359-7807
info@omega.com.mx e-mail:espanol@omega.com
OMEGAnet®Online Service Internet e-mail
omega.com info@omega.com
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omega.nl
Czech Frystatska 184 Republic: 733 01 Karviná, Czech Republic
Toll-Free: 0800-1-66342 TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: info@omegashop.cz
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: sales@omega.fr
Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Austria Toll-Free: 0 800 6397678 TEL: +49 (0) 7059 9398-0
FAX: +49 (0) 7056 9398-29 e-mail: info@omega.de
United OMEGA Engineering Ltd. Kingdom: One Omega Drive, River Bend Technology Centre, Northbank
ISO 9001
Irlam, Manchester M44 5BD England
Certified
Toll-Free: 0800-488-488 TEL: +44 (0)161 777-6611 FAX: +44 (0)161 777-6622 e-mail: sales@omega.co.uk
6
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
SM
TEMPERATURE
䡺⻬
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
䡺⻬
Wire: Thermocouple, RTD & Thermistor
䡺⻬
Calibrators & Ice Point References
䡺⻬
Recorders, Controllers & Process Monitors
䡺⻬
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
䡺⻬
Transducers & Strain Gages
䡺⻬
Load Cells & Pressure Gages
䡺⻬
Displacement Transducers
䡺⻬
Instrumentation & Accessories
FLOW/LEVEL
䡺⻬
Rotameters, Gas Mass Flowmeters & Flow Computers
䡺⻬
Air Velocity Indicators
䡺⻬
Turbine/Paddlewheel Systems
䡺⻬
Totalizers & Batch Controllers
pH/CONDUCTIVITY
䡺⻬
pH Electrodes, Testers & Accessories
䡺⻬
Benchtop/Laboratory Meters
䡺⻬
Controllers, Calibrators, Simulators & Pumps
䡺⻬
Industrial pH & Conductivity Equipment
DATA ACQUISITION
䡺⻬
Data Acquisition & Engineering Software
䡺⻬
Communications-Based Acquisition Systems
䡺⻬
Plug-in Cards for Apple, IBM & Compatibles
䡺⻬
Datalogging Systems
䡺⻬
Recorders, Printers & Plotters
HEATERS
䡺⻬
Heating Cable
䡺⻬
Cartridge & Strip Heaters
䡺⻬
Immersion & Band Heaters
䡺⻬
Flexible Heaters
䡺⻬
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
䡺⻬
Metering & Control Instrumentation
䡺⻬
Refractometers
䡺⻬
Pumps & Tubing
䡺⻬
Air, Soil & Water Monitors
䡺⻬
Industrial Water & Wastewater Treatment
䡺⻬
pH, Conductivity & Dissolved Oxygen Instruments
Loading...