Omega M1945 User Manual

FLSC-AMP-A
1
2
3
4
5
AMPLIFIER
1
2
3
4
5
OUTPUT
+ POWER SUPPLY
– SIGNAL
INPUT
POWER / COMMON
(ALSO USED FOR OUTPUT RETURN)
+ SIGNAL
MOUNTING HOLES (2)
USE 8-32 SCREWS
®
Preamplifier and Signal Conditioner for Magnetic Pick-ups
OPERATOR’S
MANUAL
General Description
The FLSC-AMP-A Signal Conditioner will amplify low level signals from magnetic pick-up sensors, such as a turbine meter or paddlewheel sensor, to an amplified high level square wave pulse output proportional in amplitude to the power supply powering the module. This output will drive any OMEGA counter, controller or pulse input data acquisition board.
Unpacking
Remove the Packing List and verify that you have received all equipment. If you have any questions about the shipment, please call the Customer Service Department.
When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any claims unless all shipping material is saved for their examination. After examining and removing contents, save packing material in the event reshipment is necessary.
The following items are supplied in the box:
• FLSC-AMP-A Signal Conditioner
• Operator’s Manual
M1945/1011
NOTE
®
flow ratemeter,
Hookup (Refer to Figure 1)
For electrical connections, the terminal strip will accommodate up to a 14 gauge wire. 18-20 gauge is recommended.
Note: The signal lines from the magnetic pick-up should be shielded and kept less than ten feet and away from relays, solenoids, or other sources of electrical noise. The signal shield should be connected to power/common. The module output is recommended to make long distance runs.
Mounting
The FLSC-AMP-A module may be mounted using the screw holes provided in the molded housing. Double­sided tape, Velcro, or glue may also be used to secure the module in place. The FLSC-AMP-A module can also be snap track mounted using an adapter plate.
Figure 1. Terminal Connections
FLSC-AMP-A Signal Conditioner
12345
.650
(16.50)
.650
(16.50)
1.750
(44.45)
DIA.
1.150
(29.21)
12345
.750
(19.05)
.185 DIA. THRU
.250 DIA. THRU
WARRANTY/DISCLAIMER
OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is VOID, if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear or which are damaged by misuse are not warranted. These include contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. Nevertheless, OMEGA only warrants that the parts manufactured by it will be as specified and free of defects.
OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. 
LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. 
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a "Basic Component" under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
UUSASA
MADE
ININ
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE  contacting OMEGA:
1. P.O. number under which the product was  PURCHASED,
2. Model and serial number of the product   under warranty, and
3. Repair instructions and/or specific problems  relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 1998 OMEGA ENGINEERING, INC. All rights reserved. This documentation may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contaction OMEGA:
1. P.O. number to cover the COST of the  repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems  relative to the product.
Specifications
Power: 8 to 24 Vdc
Input Frequency: 20 Hz to 20 KHz
Input Voltage: Sinusoidal 50mV p-p to 50V p-p
Input Impedance: 10 K ohms
Output: 100 mA sink max. with 4.7K internal pull-up resistor
Temperature Range: -10 to 60°C
Weight: 1 oz.
Dimensions
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC.
2011
Loading...