Omega LDP63100 User Manual

LLDDPP6633110000
Extra LLarge DDisplay
User’s Guide
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
OMEGAnet®Online Service
omega.com
Internet e-mail
info@omega.com
Servicing North America:
U.S.A.: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico: En Español: (001) 203-359-7803 e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING : These products are not designed for use in, and should not be used for, human applications.
3
z LARGE LED DISPLAY READABLE TO 180 FEET z VARIOUS ANALOG INPUT MODULES;
DC VOLTAGE AND CURRENT PROCESS SIGNALS TRUE RMS VOLTAGE AND CURRENT THERMOCOUPLE OR RTD STRAIN GAGE/BRIDGE
z ALARMS, ANALOG OUTPUT, AND COMMUNICA TION z PROGRAMMABLE USER INPUTS z UNIVERSAL AC POWERED (85 to 250 VAC) z PROGRAMMING SOFTWARE z NEMA 4X/IP65
GENERAL DESCRIPTION
The LDP63100 is a versatile display that can increase productivity by offering the plant floor or production area a large visual display of their current status. Whether your measurement is voltage, current, process, temperature, or strain gage, the LDP63100 can satisfy your requirement. Plug-in option cards can add alarms, analog output, and communication/bus capabilities, making the LDP63100 a truly Intelligent Panel Meter.
SAFETY SUMMARY
All safety regulations, local codes and instructions that appear in this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system.
SPECIFICATIONS
Input specifications, wiring, and programming information is contained in the corresponding literature shipped with the ordered model.
1. DISPLAY: 4" (101 mm) Red LED
5-Digit: -19999 to 99999
2. POWER REQUIREMENTS:
AC Input Modules: 85 to 250 VAC, 50/60 Hz, 18 VA LDP63100 Display: 85 to 250 VAC, 50/60 Hz, 10 VA
3. ANNUNCIATORS: Display Indication: Three vertical dots on the left side of the unit identify
the displays for the following modes:
Setpoint Indication: Four vertical dots on the right side of the unit identify
the setpoint “ON” condition, with SP 1 being the top position through SP 4 at the bottom.
4. LDP63100 Programming: The unit is a large display, designed to be remotely mounted. Therefore, the unit does not have a programming keypad. Unit programming should be accomplished by one of the following methods: Rear Terminal Block: External switches can be wired via the terminal block
to allow unit programming. Aminimum of 3 switches would be required.
Optional Programming Remote (LDP6-PGM): This option provides a 10
foot interconnecting cable and programming box. The Programming Remote contains buttons allowing easy programming of the display.
Optional Serial Programming: You can purchase an RS232 or RS485 Comms
Card and program the unit via Crimson, a Windows
®
based software
program.
DIMENSIONS In inches (mm)
CAUTION: Risk of Danger
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
TOP Maximum
MIDDLE Minimum
BOTTOM Total
C
US LISTED
U
L
R
IND. CONT. EQ.
51EB
4
WARNING: Disconnect all power to the unit before
installing Plug-in cards.
Adding Option Cards
The LDP63100 series meters can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section of the included manual. Only one card from each function type can be installed at one time. The function types include Setpoint Alarms (LDP6-CDS), Communications (LDP6-CDC), and Analog Output (LDP6-CDL). The plug-in cards can be installed initially or at a later date.
SETPOINT ALARMS PLUG-IN CARDS (LDP6-CDS)
The LDP63100 series has 4 available setpoint alarm output plug-in cards. Only one of these cards can be installed at a time. (Logic state of the outputs can be reversed in the programming.) These plug-in cards include:
LDP6-CDS10 - Dual Relay, FORM-C, Normally open & closed LDP6-CDS20 - Quad Relay, FORM-A, Normally open only LDP6-CDS30 - Isolated quad sinking NPN open collector LDP6-CDS40 - Isolated quad sourcing PNP open collector
ANALOG OUTPUT PLUG-IN CARD (LDP6-CDL)
Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available from the analog output plug-in card. The programmable output low and high scaling can be based on various display values. Reverse slopes output is possible by reversing the scaling point positions.
LDP6-CDL10 - Retransmitted Analog Output Card
COMMUNICATION PLUG-IN CARDS (LDP6-CDC)
A variety of communication protocols are available for the LDP63100 series. Only one of these cards can be installed at a time. When programming the unit via Crimson, the RS232 or RS485 Cards must be used.
PROGRAMMING SOFTWARE
DP6-SOFT is a Windows®based program that allows configuration of the LDP63100 meter from a PC. This software offers standard drop-down menu commands, that make it easy to program the LDP63100 meter. The program can then be saved in a PC file for future use. A serial plug-in card is required to program the meter using the software.
5. CERTIFICA TIONS AND COMPLIANCES:
SAFETY
UL Recognized Component, File #E313607, UL61010A-1, CSA C22.2 No. 1010-1
Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc.
UL Listed, File #E313547, UL508, CSA C22.2 No. 14-M95
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Indoor Enclosure rating (Face only), UL50
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
ELECTROMAGNETIC COMPATIBILITY
EMC specifications determined by the model.
6. ENVIRONMENTALCONDITIONS:
Operating Temperature Range: Determined by the model Storage Temperature Range: -40 to 60°C Operating and Storage Humidity: 0 to 85% max. RH (non-condensing) Altitude: Up to 2000 meters
7. MOUNTING REQUIREMENTS:
Max. panel thickness is 0.375" (9.5 mm) Min. panel thickness for NEMA 4/IP65 sealing is 0.060" (1.52 mm)
8. MODULE INSTALLATION:
24-pin shrouded connector on LDP63100 engages connector on input module
upon installation. Shroud ensures proper alignment by providing a lead-in for
the module connector.
9. CONNECTIONS: Wiring connections are made to the LDP63100 terminal
block and input module via high compression cage-clamp terminal blocks.
Input Module Wiring: Instructions are provided in the included bulletin.
LDP63100 Terminal Block Wiring:
Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-12 AWG copper wire Maximum Torque: 5-7 inch-lbs (0.58-0.81 N-m)
CAUTION: DISCONNECT ALL POWER BEFORE INSTALLING OR REMOVING MODULE
10. CONSTRUCTION: Aluminum front panel, enclosure, and rear cover with
textured black polyurethane paint for scratch and corrosion resistance
protection. Sealed front panel meets NEMA 4X/IP65 specifications for
indoor use when properly installed. Installation Category II, Pollution Degree
2. Panel gasket and keps nuts included.
11. WEIGHT: 5 lbs (2.25 kg) (less module)
OPTIONAL PLUG-IN CARDS AND ACCESSORIES
LDP6-CDC4C - Modbus (Connector)LDP6-CDC40 - Modbus (Terminal)
LDP6-CDC1C - RS485 Serial (Connector)
LDP6-CDC2C - RS232 Serial (Connector)
LDP6-CDC10 - RS485 Serial (Terminal)
LDP6-CDC20 - RS232 Serial (Terminal)
Loading...
+ 8 hidden pages