Omega FTB–1400-MD-LP, FTB–1400-SD-LP, FTB–1400-RD-LP User guide

Page 1
Shop online at
For latest product manuals:
omega.com
omegamanual.info
Series FTB–1400-MD-LP FTB–1400-SD-LP FTB–1400-RD-LP
Page 2
OMEGAnet
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
®
Online Service Internet e-mail
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified
Stamford, CT 06907-0047 Toll-Free: 1-800-826-6342 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected]
Canada: 976 Bergar
Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected]
For immediate technical or application assistance:
U.S.A. and Canada:Sales Service: 1-800-826-6342/1-800-TC-OMEGA
Customer Service: 1-800-622-2378/1-800-622-BEST Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
®
®
Mexico: En Español: 001 (203) 359-7803 FAX: (001) 203-359-7807
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Czech Republic: Frystatska 184
France: Managed by the United Kingdom Office
Germany/Austria: Daimlerstrasse 26
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: [email protected]
733 01 Karviná, Czech Republic Toll-Free: 0800-1-66342 TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: [email protected]
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: [email protected]
D-75392 Deckenpfronn, Germany Toll-Free: 0 800 6397678 TEL: +49 (0) 7059 9398-0 FAX: +49 (0) 7056 9398-29 e-mail: [email protected]
One Omega Drive, River Bend Technology Centre, Northbank Irlam, Manchester M44 5BD England Toll-Free: 0800-488-488 TEL: +44 (0)161 777-6611 FAX: +44 (0)161 777-6622 e-mail: [email protected]
Page 3
CONTENTS
INTRODUCTION...........................................................4
SPECIFICATIONS ..........................................................6
OPERATING THE MONITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
BASIC PROGRAMMING MODE .........................................7
PROGRAMMING.......................................................7
FTB–1400 Simplied 4-20 mA Programming .........................10
ADDITIONAL INPUT OPTIONS ...........................................12
TROUBLESHOOTING GUIDE .............................................17
DEFAULT KFACTOR VALUES............................................. 17
PART NUMBERING ...................................................... 18
REPLACEMENT PARTS ...................................................18
3
Page 4

INTRODUCTION

The FTB–1400 Flow Monitor is a state-of-the-art, digital signal processing ow monitor, designed to provide the user with exceptional exibility at a very aordable price. Though designed for use with Omega FTB–1400 ow meters, this display can be used with almost any ow meter producing a low amplitude AC output or contact closure signal(s).
This ow monitor is capable of accepting a low-level frequency input for calculating ow rate and total. These calculations can then be displayed in the desired units of measurement. All FTB–1400 ow monitors come pre-calibrated, from the factory, if ordered with an Omega FTB–1400 Flow Meter. If required, however, it can easily be re-congured in the eld. The monitor’s large 8 digit by .75" numeric liquid crystal display makes extend­ed range viewing practical. The second 8 digit by .38" alphanumeric display provides for selectable units viewing in run mode and prompts for vari­ables in program mode. Finally, the user can choose between displaying rate, total, or alternating between both rate and total.
FTB-1400 Series
RUN PROGRAM
RELAY1 RELAY2
ONE OMEGA DRIVE, BOX 4047
PHONE 203-359-1660 FAX 203-359-7700 www.omega.com
STAMFORD, CT 06907-0047
FLOW MONITORING SYSTEM
Figure 1: Flow Monitor Face
4
Page 5
FEATURES
• Displays Rate and/or Total
• Large 0.75 Inch, 8 Digit Display for Easy Viewing
• Simple, Front Panel Programming
• Various Mounting Styles Available
• NEMA 4X Suitable for Outdoor Mounting
• Intrinsically Safe
• Microprocessor Based, Low Power Components
• 4-20 mA Loop Powered
• Automatic Decimal Point Locating
• Lead Zero Blinking
• Surface Mount Technology Use Throughout
5
Page 6

SPECIFICATIONS

Power Supply:
4-20 mA loop power
Power Consumption:
25 mA (maximum)
Alphanumeric Rate and Total Display:
8 digit, .75" high numeric display 8 character, .38" high alphanumeric display Fixed or toggle modes of operation for ow rate and totalizer display
Pulsed Output Signal:
Outputs one pulse for each increment of the least signicant totalizer digit Max. Voltage: 30 Vdc Pulse Type: Opto-Isolated open collector transistor Pulse Width ON State: 0.9 V drop @ 5.0 mA or 0.7 V drop @ 0.1 A
Magnetic Pick-up Inputs:
Frequency Range: 0 to 3500 Hz Trigger Sensitivity: 30 mV p-p Over Voltage Protected: ±30 VDC
Frequency Measurement Accuracy: ±0.1%
Temperature Drift: 50 ppm / ºC (max)
Transient Overvoltages: Category 3, in accordance with IEC664
Pollution Degree: 2, in accordance with IEC664
Mounting Classication:
Meter Mount: NEMA 4X Enclosure Remote Mount: NEMA 4X Enclosure Swivel Mount: NEMA 4X Enclosure
Environmental:
Operating Temperature: -22 ºF to +158 ºF (-30 ºC to +70 ºC) Humidity: 0-90% Non-condensing
Units of Measure:
Gallons, Oil Barrels, Liters, Cubic Meters, MGal, Cubic FT, MCF, MMCF Megltrs, Acre FT, Liq. Barrels, LBS, KGS Time Intervals: Day, Hour, Minute, Second
6
Page 7

OPERATING THE MONITOR

The monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode. Both the run mode and the program mode display screen enunciators conrming the state of the monitor. A quick glance at the lower left hand corner of the LCD screen will conrm operating status. Normal operation will be in the RUN mode. To access the program mode, press the MENU button until the rst programming screen is displayed. After programming the display with the necessary information, a lock out feature can be turned on to prevent unauthorized access or changing the meter’s setup parameters.

BASIC PROGRAMMING MODE

Keys:
MENU – Switch between RUN and PROGRAM modes
UP Arrow – Scrolls through programming sub-menus in forward
direction and increments numeric variables
RIGHT Arrow – Scrolls through programming sub-menus in reverse direction and moves the active digit to the right
ENTER – Used to enter sub-menus, save programming information and in the reset process
If your monitor was ordered with an Omega ow meter, the two compo­nents ship from the factory calibrated as a set. If the monitor is a replace­ment, the turbine’s K-factor has changed, or the monitor is being used with some other pulse generating device, programming will be necessary.

PROGRAMMING

Each turbine ow meter is shipped with either a K-factor value or frequency data. If frequency data is provided, the data must be converted to a K-factor before programming. K-factor information, when supplied, can usually be found on the neck of the ow meter or stamped on the body. The K-factor represents the number of pulses per unit of volume. The K-factor will be needed to program the monitor.
ENTER PROGRAM MODE – Change to program mode by press­ing the MENU button once. The mode indicator will change from RUN to PROGRAM.
7
Page 8
NOTE: If any input value exceeds the meter's capabilities for that particular parameter, the LIMIT indicator will begin to ash indicating an invalid entry. Press ENTER once to return to the parameter’s entry screen to reenter the value.
SELECT THE METER SIZE – At the METER prompt, press the ENTER but­ton once. The current meter size number will begin to ash. Using the arrow keys, scroll through the size choices until you nd the bore size of your meter. Press ENTER once to save the meter size choice.
NOTE: The meter connection size and the bore size are dierent. For example, many of the 1” NPT turbines have bore sizes that range from 3⁄8” up to 1”. Be sure to use the correct bore size or the meter will report incorrect ows and totals.
Mode
Indicator
Programming
Keys
FTB-1400 Series
RUN PROGRAM
RELAY1 RELAY2
ONE OMEGA DRIVE, BOX 4047
STAMFORD, CT 06907-0047
PHONE 203-359-1660 FAX 203-359-7700 www.omega.com
Rate / Total Display
And
Programming Choices
FLOW MONITORING SYSTEM
Units Display
And
Programming Choices
Figure 2: Flow Monitor Controls
8
Page 9
ENTER THE METER’S K-FACTOR UNIT – Directly after the METER size is selected, the display’s K-factor unit must be chosen. Use the UP arrow key to select your K-factor unit. For meters calibrated in gallons, use PUL/GAL (pulses per gallon); for meters calibrated in cubic meters, use PUL/M3 (pulses per cubic meter), etc. Press ENTER to save the K-factor unit and advance to the next parameter.
NOTE: Unless otherwise specied, Omega turbine ow meters are supplied with K-factors measured in pulses per gallon (PUL/GAL) which will automatically convert to your desired units of measure.
NOTE: The K-factor supplied with the meter or calculated from calibration data will be needed to complete the next step..
SELECT THE RATE/TOTAL UNITS OF MEASURE – The monitor allows the choice of ve common rate/total units. The monitor shows the rate/ total unit that the display is currently set for. If the current selection is correct, press the ENTER key once to advance to the next parameter. To change to an alternate unit, use the arrow keys to scroll to the desired rate unit and press ENTER to save the choice.
Selection Rate Total
GPM/GAL Gallons per Minute Gallons
LPM/LIT Liters per Minute Liters
M3PH/M3 Cubic Meters per Hour Cubic Meters
M3PD/M3 Cubic Meters per Day Cubic Meters
BPD/BBL Oil Barrels per Day Oil Barrels
NOTE: The total unit’s output multiplier cannot be modied in the Simplied program level. This option is reserved in the Advanced program level.
SELECT THE DISPLAY FUNCTION – The monitor can display RATE or TOTAL or alternate between BOTH rate and total. At the DISPLAY prompt, press the ENTER key once. The monitor now shows the display mode currently in eect. If the current selection is correct, press the ENTER key to advance to the next parameter. To change to an alternate display mode, use the ar­row keys to scroll to the desired display mode and press ENTER to save the choice.
A TEST function is also available in the Display Function sub-menu. With the test function selected, the display acts like a frequency counter and displays the raw input frequency being supplied to the frequency input terminals. This is very useful when troubleshooting ow problems.
9
Page 10
TOTALIZER PULSE OUTPUT – The pulse output parameter can be either enabled or disabled. When enabled this output generates 20 mS duration pulse for every time the least signicant digit of the totalizer increments. The amplitude of the pulse is dependent on the voltage level of the supply connected to the pulse output and is limited to a maximum 30 VDC.
FTB1400 SIMPLIFIED 420 MA PROGRAMMING
FLOW 4mA SETTING – When the loop powered option is ordered, the
ow rate that corresponds to 4mA must be set. Zero is default ow rate for this setting. If the current selection is correct, press the ENTER key once to advance to the next parameter. If adjustment is required, use the RIGHT arrow key to select the position of the number you wish to change. Then use the UP arrow key to increment the number. Once you have completed this step, press the ENTER key to advance to the next parameter.
FLOW 20mA SETTING – The ow rate that corresponds to 20mA must be set next. The turbine meter’s maximum ow rate is the default value. If the current selection is correct, press the ENTER key once to advance to the next parameter. If adjustment is required, use the RIGHT arrow key to select the position of the number you wish to change. Then use the UP arrow key to increment the number. Once you have completed this step, press the ENTER key to advance to the next parameter.
4-20mA CALIBRATION – When ordered with a 4-20mA option, this menu item allows the ne adjustment of the 4-20mA output. The 4mA setting is typically between 35 and 50. To set the 4mA value, connect an ammeter in series with the loop power supply. At the 4mA OUT prompt, adjust the 4mA value to obtain a 4mA reading on the amme­ter. The UP arrow key increments the value and the RIGHT arrow key decrements the value. When a steady 4mA reading is obtained on the ammeter, press the ENTER key to lock in this value and move to the 20mA adjustment. The 20mA adjustment is performed using the same procedure as the 4mA adjustment.
4-20mA TEST – The monitor contains a diagnostic routine that allows the simulation of mA values between 4 and 20 to check output track­ing. At the 4-20TEST prompt the arrow keys change the simulated mA output in increments of 1mA. The ammeter should track the simulated mA output. If a 4-20mA test in not necessary, pressing the ENTER key once will escape the testing at any time.
10
Page 11
Mag
J2
Input
Keypad
Connector
DC
1 2 3 4 5
JP2
Pulse Inuput
+10 - 30 VDC
+1 - 5 VDC
1 2 3 4 5 6
-
+
+ -+
Pulse Out Freq. In4-20 mA
TB1
-
Figure 3: Typical Ammeter Connection
PASSWORD – Password protection prevents unauthorized users from changing programming information. Initially, the password is set to all ze­ros. To change the password, simply enter any 4 digit code using the arrow keys as previously described to enter the password value. Pressing ENTER once will store the password and take you back to the RST PSWD screen.
NOTE: This password will allow the operator to manually reset totals.
RST PSWD – The reset password screen allows the operator to enter any 4 digit code for the manual reset totals function.
RESET TOTAL – To reset the monitor total display, in RUN mode press the MENU and ENTER simultaneously until TOTAL RST starts to ash. The TOTAL RST will stop ashing and the display will return to the RUN mode at the conclusion of the reset procedure.
STORE TOTAL – The current total can be manually stored in the monitor’s ash memory. Press and hold the ENTER key for 2 seconds. The display will respond with a ashing TOTALSVD and then return to the RUN mode.
AUTOMATIC STORE TOTAL – The monitor is equipped with a store total feature that works automatically, saving the current total to ash memory. The frequency of saves depends on the power supply option chosen.
11
Page 12
Loop Powered: Once every ten minutes.
+10 - 30 VDC

ADDITIONAL INPUT OPTIONS

The FTB–1400 Flow Monitor is capable of receiving magnetic pick-up input (small signal sine wave) or a contact closure input (pulse). Since Omega FTB–1400 Flow Meters utilize a magnetic pick-up, the monitor is shipped congured for magnetic pick-up input. To change to a contact closure in­put, remove JP2 from the top two pins and jumper them to the bottom two pins. See Figure 4.
LOOP POWERED
20 mS Pulse
+1 - 5 VDC
+30 VDC (Max)
10K
250 Typ
R
(Loop Supply Voltage - 5)
=
MAX
0.02
Figure 4: Wiring Diagram
Keypad
Connector
1 2 3 4 5
1 2 3 4 5 6
+ -+ -+
Pulse Out Freq. In4-20 mA
JP2
-
Mag Input
Pulse
Inuput
TB1
J2
Magnetic Pickup
12
Page 13
K Factor Unit
Units
Pulse Output
Simplied Menu
Figure 5: Basic Programming Menu
13
Page 14
5.75"
7.00"
3.93"
8.93"
7.00"
7.00"
RUN PROGRAM
RELAY1 RELAY2
MENU ENTER
METER DISPLAY
14
2.40" TYP.
2.25" TYP.
5.75"
RUN PROGRAM
RELAY1 RELAY2
MENU ENTER
4.30"
REMOTE DISPLAY
Page 15
3.93"
5.75"
12.25"
RUN PROGRAM
RELAY1 RELAY2
MENU ENTER
7.00"
SWIVEL MOUNT
Figure 6: MOUNTING OPTIONS
15
Page 16
WIRE HARNESS
SWIVEL MOUNT
METER MOUNT OR
SCALE: .75 = 1
SWIVEL MOUNT DETAIL
METER MOUNT
OR SWIVEL MOUNT
MAGNETIC PICK-UP
REMOTE CABLE WITH STRAIGHT AMPHENOL
CONNECTOR OR REMOTE CABLE WITH
90° AMPHENOL CONNECTOR
MAGNETIC PICKUP
10 FT. TO MAX. 100 FT.
STRAIGHT TO TURBINE
CONNECTOR 90° OR
OPTIONAL AMPHENOL
WIRE HARNESS
FTB-1400 SERIES
TURBINE METER
16
Figure 7: Installation Drawing
Page 17

TROUBLESHOOTING GUIDE

Trouble Remedy
No LCD Display
No Rate or Total Displayed
Flow Rate Display Interprets Reading Constantly
Flow Rate Indicator Bounces
• Check power supply voltage. Should be between 10 and 30 Vdc.
• Check connection from meter pick-up to display input terminals.
• Check turbine meter rotor for debris. Rotor should spin freely.
• Check programming of ow monitor.
• This is usually an indication of external noise. Keep all AC wires separate from DC wires.
• Check for large motors close to the meter pick-up.
• Check for radio antenna in close proximity.
• Try disconnecting the pick-up from the monitor pig tail. This should stop the noise.
• This usually indicates a weak signal. Replace pick-up and/or check all connections.
• Examine K-factor.
DEFAULT KFACTOR VALUES
Meter Size Default K-factor Lower Limit Upper Limit
0.375 20,000 16,000 24,000
0.500 13,000 10,400 15,600
0.750 2,750 2,200 3,300
0.875 2,686 2,148 3,223
1.000 870.0 696.0 1,044
1.500 330.0 264.0 396.0
2.000 52.0 41.6 62.0
3.000 57.0 45.6 68.0
4.000 29.0 23.2 35.0
6.000 7.0 5.6 8.0
8.000 3.0 2.4 4.0
10.000 1.6 1.3 2.0
17
Page 18

PART NUMBERING

FTB–1400–XD–LP
Mounting Style
M - Meter Mount R - Remote Mount S - Swivel Mount

REPLACEMENT PARTS

Component Part Number
Keypad B260713
Pick-up Cable B222-121
Desiccant Bag B260630
PVC Union B220016
PVC Reducer Bushing B220056
Rubber Washer B228207
Steel Lock Washer B220018
Desiccant Shield B280680
Cord Grip B220103
18
Page 19
WARRANTY/ DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moistur e or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified a nd free of
defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty,
negligence, indemnification, strict liability or otherwise, shall not exceed the
purchase price of the component upon which liability is based. In no event shall
OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1)
as a “Basic Component” under 10 CFR 21 (NRC), used in or with any activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
nuclear installation or
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
RETURN REQUESTS/INQUIRIES
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number s hould then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY
the following information available BEFORE
contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, w henever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2009 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
RETURNS, please have
FOR NON-WARRANTY REPAIRS, OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
consult
2. Model and serial number of theproduct, and
3. Repair instructions and/or specific problems relative to the product.
Page 20
Where Do I Find Everything I Need for
Process Measurement and Control?
M-5299/0613
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging System s
Recorders, Printers & Plotters
SM
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
Loading...