Omega Platinum, CS8DPT, CS8EPT User Manual

CS8DPT/CS8EPT
Universal Benchtop
Digital Controller
Omega.com info@omega.com
U.S.A.:
Omega Engineering, Inc. Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
2
Introduction
TABLE OF CONTENTS
1 INTRODUCTION ................................................................................................................. 3
1.1 Safety and Precautions ................................................................................................................. 3
1.2 Cautions and IEC Symbols ............................................................................................................. 3
1.3 Statement on CE Marking ............................................................................................................. 3
1.4 Available Models ........................................................................................................................... 3
1.5 Communication Options ............................................................................................................... 4
1.6 Reference Manuals ....................................................................................................................... 4
2 UNPACKING ...................................................................................................................... 4
2.1 Inspection ...................................................................................................................................... 4
2.2 Power Cords .................................................................................................................................. 5
3 HARDWARE SETUP ............................................................................................................ 5
3.1 Front Panel .................................................................................................................................... 5
3.2 10-PIN Connector Wiring Diagrams .............................................................................................. 6
3.3 Universal Thermocouple Connector ............................................................................................. 7
3.4 Rear Panel ..................................................................................................................................... 8
3.5 Isolated Analog Output ................................................................................................................. 8
4 CONFIGURATION AND PROGRAMMING ............................................................................ 9
4.1 PLATINUM Series Navigation ........................................................................................................ 9
4.2 Selecting an Input (INIt>INPt) ..................................................................................................... 10
4.3 Set the Setpoint 1 Value (PRoG > SP1) ........................................................................................ 10
4.4 Set up the Control Output .......................................................................................................... 11
4.4.1 Select an Output Channel (PRoG > StR1/dC1/IAN1) ....................................................... 11
4.5 On/Off Control Mode (PRoG > {Output} > ModE > oN.oF) ......................................................... 11
4.6 PID Control .................................................................................................................................. 12
4.6.1 PID Configuration (PRoG > PId.S) .................................................................................... 12
4.6.2 Follow these steps to run an Autotune procedure: ........................................................ 12
4.7 Retransmission Using the Analog Output ................................................................................... 13
4.7.1 Select an Output Type ..................................................................................................... 13
4.7.2 Set Mode to Retransmission ........................................................................................... 13
4.7.3 Set Scaling ....................................................................................................................... 13
5 SPECIFICATIONS .............................................................................................................. 14
6 MAINTENANCE ................................................................................................................ 15
6.1 Cleaning ....................................................................................................................................... 15
6.2 Calibration ................................................................................................................................... 15
6.3 Fuse Specifications and Replacement ......................................................................................... 15
3
Introduction
1 INTRODUCTION
The Platinum Series Universal Benchtop Digital Controller, is ideal for laboratory and other applications requiring portable, temperature, process or strain, measurement and control. It features a universal input which reads most temperature, process and bridge type inputs. The Benchtop Digital Controller has excellent accuracy and is factory calibrated to give optimum performance over its full operating range.
1.1 Safety and Precautions
It is important to read and follow all precautions and instructions in this manual and other referenced manuals, before operating or commissioning this device, as it contains important information relating to safety and EMC.
Do not exceed the voltage rating.
Always disconnect the power before changing the signal and power connections.
Do not operate in flammable or explosive environments.
Never operate with a power cord that is not properly rated for use with this unit.
Remove and or disconnect main power cord before attempting any maintenance or fuse
replacement.
Do not connect and/or operate this unit to a non-grounded or non-polarized outlet or power
source.
There are no user serviceable parts inside the unit. Attempting to repair or service the unit may void the warranty. This product is not designed for medical applications.
1.2 Cautions and IEC Symbols
This device is marked with international safety and hazard symbols shown in the table below, in accordance with 2014/35/EU Low Voltage Directive. It is important to read and follow all precautions and instructions in this manual before operating or commissioning this device as it contains important information relating to safety and EMC. Failure to follow all safety precautions may result in injury and/or damage to the controller. Use of this device in a manner not specified by the manufacturer may impair protection devices and safety features provided by the unit.
IEC Symbol
Description
CAUTION, risk of electrical shock
CAUTION, refer to accompanying documents
1.3 Statement on CE Marking
OMEGA’s policy is to comply with all worldwide safety and EMI/EMC regulations that apply to CE Certification standards, including EMC Directive 2014/30/EU Low Voltage Directive (Safety) Directive 2014/35/EU, and EEE RoHS II Directive 2011/65/EU. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the marking to every applicable device upon verification of compliance.
1.4 Available Models
Model
Features
CS8DPT-C24-EIP-A
Benchtop Controller with 4-Digit Display, Embedded Ethernet, Serial Communication, and Isolated Analog Output
-EIP
Ethernet
-C24
Isolated RS232 and RS485
-A
Isolated Analog Output
CS8DPT
Benchtop Controller, Universal input with 4-Digit Display
CS8EPT
Benchtop Controller, Universal input with 6-Digit Display
CS8EPT-C24-EIP-A
Benchtop Controller with 6-Digit Display, Embedded Ethernet, Serial Communication, and Isolated Analog Output
4
Unpacking
1.5 Communication Options
Number
Title
M5461
Platinum Series Configurator Software Manual
M5451
Platinum Series Temperature and Process Controllers Manual
M5452
Serial Communication Protocol Manual
M5458
Platinum Series User Manual - Modbus Interface
Save packaging material and carton in the event that returns are necessary. The carrier will not honor any damage claims unless all original shipping material is saved for inspection.
Item
Name
Description
1
Unit
Universal Benchtop Digital Controller
2
Power Cord
AC Power Cord (Ordered Separately; Refer to Table 2)
3
Output Cord
Output Cords for Wiring Equipment (QTY 2)
4
Wire Kit
Accessories for RTD and Bridge Inputs
5
Guide
MQS5451 (Quick Start Guide)
The Platinum Series Benchtop Digital Controller comes with a USB port standard. Optional Serial and Ethernet connectivity is also available. All communication channels can be used with the Omega Platinum Configurator software and support both the Omega ASCII protocol and the Modbus Protocol. Refer to the Reference Manuals below for supporting documentation. The Platinum Configurator software (M5461), user manuals and more are available from the Omega website.
1.6 Reference Manuals
2 UNPACKING
Read the packing list, it is important to verify all equipment shipped has been delivered as shown in Figure 1 and Table 1. If there are any questions about the shipment, please email or call the Customer Service Department listed in this manual.
2.1 Inspection
Inspect the shipment container and equipment for any signs of damage. Record any evidence of rough handling in transit and report any damage immediately to the shipping agent.
Figure 1. Accessories Packaged with CS8DPT/CS8EPT Unit.
Table 1. Packing Contents.
5
Hardware Setup
2.2 Power Cords
Electrical power is delivered to the Benchtop Digital Controller by an AC power cord which plugs into the IEC 60320 C-13 power socket located on the rear panel of the unit. Refer to
Figure 7 for detailed connections.
The input power is fused on the Line terminal. Output connectors are fused on the Line terminal.
The Benchtop Digital Controller operates from 90 to 240 VAC @ 50-60 Hz. A main power cord may be ordered with the unit. Select the appropriate power cord for your region from Table 2.
Table 2. Power Cords
PWR Cord Type
Part Number
PWR Rating
United Kingdom, Ireland
Power Cord-UK
240V
Denmark
Power Cord-DM
230V, 16A
USA, Canada, Mexico
Power Cord-Molded
120V
Italy
Power Cord-IT
230V, 16A
Continental Europe
Power Cord E-10A
240V, 10A
Europe
Power Cord E-16A
240V, 16A
3 HARDWARE SETUP
This section details the parts of the Benchtop Controller and includes wiring diagrams to connect common inputs.
3.1 Front Panel
The controls, indicators and input connections of the Benchtop Digital Controller are located on the front of the controller as shown in Figure 2.
Figure 2. Front Panel. (Not to scale)
Table 3. Front Panel Components List.
Item
Name
Description
1
10-Pin Input Connector
Process, Strain, RTD and Thermistor Inputs
2
Display
Four-digit, three-color, LED Display
3
Adjustable Feet
Adjusts viewing angle
4
Push Buttons
Menu Navigation
5
Thermocouple Input
Miniature Thermocouple Connector input
6
USB Port
USB Port, Type A Female
Loading...
+ 11 hidden pages