Omega A, B User Manual

Model A and B
Dialtemp™ Dial Thermometers
INSTRUCTION
SHEET
M0055/0702
INSTALLING THE THERMOMETER
Model A and B Dial Thermometers are supplied standard with a
1
2" NPT hex mounting nut. Carefully screw the thermometer into the fitting by hand until slightly tight. Complete tightening using a
7
8" wrench on the hex nut. (See Figure
1). When using a thermowell, tighten only
FINGER TIGHT. CAUTION: NEVER TIGHTEN BY TWISTING THE HEAD! To obtain a positive
seal, coat threads with pipe joint compound, or use Teflon
®
tape.
When inserting Dialtemp™ Dial Thermometers into semi-solid materials, hold stem firmly and insert slowly and carefully to avoid bending. Do not hold thermometer by the head when inserting into a material, always hold by the stem.
A
1
4" NPT mounting nut, 3⁄4" NPT Adapter bushing and plain hex bushing (with no threads) are also available as mounting options for the Model A and B Dial Thermometers.
It is not always desirable to permanently mount Dialtemp™ Thermometers. Clip Hangers (Model C-10) and Spring Handles (T-27) are available
as a mounting option. They are used for mounting thermometers on the rim of tanks, kettles, urns, solder pots, beakers and other containers. Simply slide the metal clip onto the
1
⁄4" stem of the thermometer and lower it into the
liquid.
CAUTION: Avoid handling the thermometer by the stem or bending the stem when carrying it around.
SILICONE-FILLED THERMOMETERS
OMEGA provides the same features in its special order silicone-filled thermometers as the standard 3" and 5" styles. They are offered for severe industrial applications where vibration is a problem. Silicone is a non-toxic viscous fluid. Its dampering characteristics prevent wear and tear on internal parts and improve readability by reducing flutter.
To specify, add “-SF” to the end of the part number.
THERMOWELLS
Thermowells should be used whenever the
stem would be exposed to pressure, corrosion, or shear forces. They also make it possible to remove the thermometer without losing pressure or contents.
OPERATING INSTRUCTIONS
For the correct temperature, the stem of the Dial Thermometer must be immersed at least 2" in fluids and 4" in gases. An exception to this rule are thermometers with the ranges of 0­100°F, 24-125°F, and 0-50°C. These require at least 3
1
2" in liquid and 5" in gas.
TO RESET THE DIAL
1. Determine the room temperature using a reference thermometer of known accuracy.
2. Firmly hold the hex mounting nut in the hand or with a
7
8" wrench.
3. While firmly holding the thermometer, slowly turn the RESET SCREW with a screwdriver (or
1
4" wrench). The dial face INSIDE the head will rotate as the screw is turned. Slowly turn the reset screw until the proper temperature on the dial face is aligned with the pointer.
.250
Reset Screw
Specify stem length between these points
.69
3.00
.14
.31
.63
Mounting Nut – 1/2" NPT
MODEL A DIMENSIONS
FIGURE 1
SPECIFICATIONS:
ACCURACY: ±1% of full scale
RESPONSE TIME:
Readings are stabilized within 40 seconds.
RECALIBRATION:
External with 1⁄4" nut reset screw.
MATERIALS CONSTRUCTION: Stainless steel welded
construction (rust and corrosion-proof, leak-proof, hermetically sealed)
HEAD & BEZEL: Polished Type 302
stainless steel.
MOUNTING NUT: Type 303 stainless steel,
7
8" Hex, 1⁄2" HPT
DIAL FACE: Anodized aluminum with
raised black marks and numbers with satin matte finish background. Easy to read. Minimum parallax.
STEM:
1
4" Dia. 304 Stainless Steel (highly resistant to corrosion)
CRYSTAL: Optically clear strong
glass. Unbreakable clear polycarbonate plastic crystals are on all silicone­filled models which are not recommended for ranges over 300° F.
DIMENSIONS
HEAD DIAMETER:
Model A; 3" dia. Model B; 5" dia.
STEM DIAMETER:1⁄4" dia.
STEM LENGTH: Standard is 9". Also
available: 2
1
2", 4", 6", 12", 15", 18", 24", 30", 36" (Stems over 36" are also available, consult Sales Department for pricing). Intermediate lengths available on special order (allow 5 weeks). NOTE: A 4" stem is the shortest length for ranges 0-100°F, 25-125°F, and 0-50°C.
POINTED STEMS:
Optional on all models. They are excellent for probing asphalt, compost, soil, frozen foods and other semi-solid materials.
RESET SCREWS:
1
4" Hex Nut with slot for
.250
Reset Screw
Specify stem length between these points
.69
5.00
.14
.31
.63
Mounting Nut – 1/2" NPT
MODEL B DIMENSIONS
FIGURE 2
Teflon®is a registered trademark of DuPont.
150
100
200
250
300
350
400
°F
50
O
M
E
S
T
A
450
500
G
A
M
E
F
N
O
G
R
I
N
D
E
,
.
E
C
C
R
N
I
I
N
,
G
O
N
N
E
C
T
I
C
7
U
0
T
0
6
0
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR W
ARRANTY RETURNS, please have the following
information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-W
ARRANTY
REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to
the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced
to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
Servicing North America:
USA: One Omega Drive, Box 4047
ISO 9001 Certified Stamford CT 06907-0047
Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico: En Espan˜ol: (001) 203-359-7803 e-mail:espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
OMEGAnet®Online Service Internet e-mail
www.omega.com info@omega.com
Servicing Europe:
Benelux: Postbus 8034, 1180 LAAmstelveen, The Netherlands
Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl
Czech Republic: Rudé armády 1868, 733 01 Karviná 8
Tel: +420 (0)69 6311899 FAX: +420 (0)69 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France: 11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 29 00 FAX: +33 (0)1 30 57 54 27 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
Loading...