Omcan RS-CN-0250 Service Manual

Page 1
Open Refrigerated Display Case
Model RS-CN-0250
Item 25825
Revised - 01/14/2020
Toll Free: 1-800-465-0234
Fax: 905-607-0234
Email: service@omcan.com
www.omcan.com
Page 2
Table of Contents
Model RS-CN-0250
Section
Disclaimer
General Information
Safety and Warranty
Technical Specications
Handling and Assembly
Operation
Maintenance
------------------------------------------------------------------------------------------------------ 3
------------------------------------------------------------------------------------- 4 - 5
------------------------------------------------------------------------------------- 5 - 6
------------------------------------------------------------------------------------------------------- 8
--------------------------------------------------------------------------------------------------- 9
Page
------------------------------------------------------------------------------------ 7
--------------------------------------------------------------------------------- 7 - 8
Troubleshooting
Controller Instructions
Parts Breakdown
Electrical Schematics
Warranty Registration
----------------------------------------------------------------------------------------- 9 - 10
-------------------------------------------------------------------------------------- 15 - 17
------------------------------------------------------------------------------- 11 - 14
-------------------------------------------------------------------------------------- 18
-------------------------------------------------------------------------------------- 19
2
Page 3
Disclaimer
OMCAN IS NOT RESPONSIBLE FOR
ANY DAMAGES DUE TO WATER LEAKS.
WARRANTY FOR WATER LEAKS IS VOID
IF THE AMBIENT ROOM TEMPERATURE
EXCEEDS 75°F AND 55% RELATIVE HUMIDITY,
AND THE APPLIANCE DRAIN IS NOT
CONNECTED DIRECTLY TO A FLOOR DRAIN.
3
Page 4
General Information
Omcan Manufacturing and Distributing Company Inc., Food Machinery of America, Inc. dba Omcan and Omcan Inc. are not responsible for any harm or injury caused due to any person’s improper or negligent use of this equipment. The product shall only be operated by someone over the age of 18, of
sound mind, and not under the inuence of any drugs or alcohol, who has been trained in the correct operation of this machine, and is wearing authorized, proper safety clothing. Any modication to the machine voids any warranty, and may cause harm to individuals using the machine or in the vicinity of the machine while in operation.
CHECK PACKAGE UPON ARRIVAL
Upon receipt of an Omcan shipment please inspect for external damage. If no damage is evident on the external packaging, open carton to ensure all ordered items are within the box, and there is no concealed damage to the machine. If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be
lled out within three days, from the delivery date shown in the shipping documents. Omcan has no recourse
for damaged products that were shipped collect or third party.
Before operating any equipment, always read and familiarize yourself with all operation and safety
instructions.
Omcan would like to thank you for purchasing this machine. It’s of the utmost importance to save these instructions for future reference. Also save the original box and packaging for shipping the
equipment if servicing or returning of the machine is required.
---------------------------------------------------------------------------------------------------------------------------------------------------
Omcan Fabrication et distribution Companie Limité et Food Machinery d’Amerique, dba Omcan et Omcan Inc. ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipement de façon irrégulière. Le produit ne doit être exploité que par quelqu’un de
plus de 18 ans, saine d’esprit, et pas sous l’inuence d’une drogue ou d’acohol, qui a été formé pour utiliser cette machine correctement, et est vêtu de vêtements de sécurité approprié. Toute modication
de la machine annule toute garantie, et peut causer un préjudice à des personnes utilisant la machine ou des personnes à proximité de la machine pendant son fonctionnement.
VÉRIFIEZ LE COLIS DÈS RÉCEPTION
Dès réception d’une expédition d’Omcan veuillez inspecter pour dommages externes. Si aucun dommage
n’est visible sur l’emballage externe, ouvrez le carton an de s’assurer que tous les éléments commandés
sont dans la boîte, et il n’y a aucun dommage dissimulé à la machine. Si le colis n’a subi aucune mauvaises manipulations, de bosses ou de dommages (visible ou cachée), notez-le sur le bond de livraison avant
d’accepter la livraison et contactez Omcan dans les 24 heures qui suivent, pour que nous puissions engager
une réclamation auprès du transporteur. Un rapport détaillé sur l’étendue des dommages causés à la machine
doit être rempli dans un délai de trois jours, à compter de la date de livraison indiquée dans les documents d’expédition. Omcan n’a aucun droit de recours pour les produits endommagés qui ont été expédiées ou cueilli
par un tiers transporteur.
4
Page 5
General Information
Avant d’utiliser n’importe quel équipement, toujours lire et vous familiariser avec toutes les opérations et les consignes de sécurité.
Omcan voudrais vous remercier d’avoir choisi cette machine. Il est primordial de conserver ces
instructions pour une référence ultérieure. Également conservez la boîte originale et l’emballage pour
l’expédition de l’équipement si l’entretien ou le retour de la machine est nécessaire.
---------------------------------------------------------------------------------------------------------------------------------------------------
Omcan Empresa De Fabricacion Y Distribucion Inc. Y Maquinaria De Alimentos De America, Inc. dba Omcan y Omcan Inc. no son responsables de ningun daño o perjuicío causado por cualquier persona inadecuada o el uso descuidado de este equipo. El producto solo podra ser operado por una persona
mayor de 18 años, en su sano juicio y no bajo alguna inuencia de droga o alcohol, y que este ha sido entrenado en el correcto funcionamiento de esta máquina, y ésta usando ropa apropiada y autorizada. Cualquier modicación a la máquina anúla la garantía y puede causar daños a las personas usando la
máquina mientras esta en el funcionamiento.
REVISE EL PAQUETE A SU LLEGADA
Tras la recepcion de un envio Omcan favor inspeccionar daños externos. Si no hay daños evidentes en el
empaque exterior, Habra el carton para asegurararse que todos los articulos solicitados ésten dentro de la caja y no encuentre daños ocultos en la máquina. Si el paquete ha sufrido un manejo de poco cuidado, golpes
o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro
de las 24 horas, de modo que podamos iniciar una reclamación con la compañia. Un informe detallado sobre los daños causados a la máquina debe ser llenado en el plazo de tres días, desde la fecha de entrega que se muestra en los documentos de envío. Omcan no tiene ningun recurso por productos dañados que se enviaron
a recoger por terceros.
Antes de utilizar cualquier equipo, siempre lea y familiarizarse con todas las instrucciones de
funcionamiento y seguridad.
Omcan le gustaría darle las gracias por la compra de esta máquina. Es de la mayor importancia para salvar estas instrucciones para futuras consultas. Además, guarda la caja original y el embalaje para el
envío del equipo si servicio técnico o devolución de la máquina que se requiere.
Safety and Warranty
Cautions:
Never block the air suction outlet to keep air circulation and refrigeration capability.
Do not overll the unit or it may hinder its operation.
Adjust the rack height for proper food storage.
5
Page 6
Safety and Warranty
Use and Caution:
Cool hot food before placing it in the refrigerator.
Only trained technicians should repair damaged power cables with special tools.
Never touch the compressor to avoid injury.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with or around the appliance.
The operation manual is not suitable for persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge.
OMCAN IS NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS. WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75°F AND 55% RELATIVE HUMIDITY, AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECTLY TO A FLOOR DRAIN.
1 YEAR PARTS AND LABOUR WARRANTY
Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized
service technician to repair the equipment locally.
Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not
improper use.
Please see https://omcan.com/disclaimer for complete info.
WARNING:
The packaging components (cardboard, polyethylene, and others) are classied as normal solid urban waste and can therefore be disposed of without difculty.
In any case, for suitable recycling, we suggest disposing of the products separately (differentiated waste) according to the current norms.
DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!
6
Page 7
Technical Specications
Model RS-CN-0250 Power 1380 W
Electrical Heating Element 450 W Capacity 252 L / 8.9 cu. ft. Electrical 110V / 60Hz / 1Ph
Lamp Power 1.44x4 (LED)
Temperature Range 2°C - 10°C / 35.6°F - 50°F Refrigerant & Injection R290 (148g)
Blowing Gas C5H10
Type of Climate 6 Rated Current 14.5A
Shelf Sizes
Dimensions 24” x 29.7” x 67.1” / 610 x 754 x 1704mm Interior Dimensions 21.8” x 22” x 38.5” / 552 x 559 x 978mm Weight 282 lbs. / 127.9 kgs. Item Number 25825
15” x 21.75” (2pcs.) / 381 x 552mm (2pcs.)
12” x 21.75” (1pc.) / 305 x 552mm (1pc.)
Handling and Assembly
Handle with care
Unplug the wall socket rst. Never tilt it over 45
degrees when handling.
Sufcient space
The distance from both sides and back of refrigerator to wall or other substance must be no less than 10 cm. The refrigeration capability may decrease if its surrounding space is too small to circulate air.
Far from heat source
Never place the refrigerator direction under sunlight. Never locate it near any heat source to prevent reducing refrigeration capability.
Do not make holes
Never make any holes on the refrigerator. Do not attach any objects onto the refrigerator.
Dry place
Always locate the refrigerator in a dry location.
Well ventilated
Always locate the refrigerator in an area with good
ventilation. When using for the rst time, wait for 24
hours after handling to start.
No heavy load
Never put any heavy objects on top of the refrigerator.
Stable Location
Unpack and place the refrigerator on at and stable
ground.
7
Page 8
Handling and Assembly
Exclusive power socket
Normally, the power supply should be 100 – 110V, 60
Hz single phase AC with exclusive single phase two
pin receptacle.
Protect cables
Never break or damage the cables as this may cause electrical shock.
Avoid ammable and explosive objects
Never put any ammable or explosive items inside
the refrigerator such as gasoline or alcohol. Never put any dangerous product nearby the refrigerator.
After power break
After power break or unplugging the refrigerator, always wait at least 5 minutes before starting the refrigerator again.
Operation
Before use:
Do not share the socket
Never let the refrigerator share a socket with another appliance. The cable may become hot and this may
cause a re.
No water ushing
Never give the refrigerator surface a ush otherwise
electrical shock may occur.
No spray
Do not spray the unit with a ammable substance such as paint. This may result in a re.
No medicine
No medicine is allowed to be kept inside the refrigerator.
Plug the refrigerator into 110V exclusive socket. Unit must have independent breaker. After the refrigerator is running, test the air suction to conrm that it is sufciently cold. Then you may put food and drinks inside, once
unit reaches temperature.
Parameter Settings
Factory initial Setting: E1=-1, E2=8, E3=6, E4=3, E5=2, E6=0, F1=25, F2=3, F3=15, F4=0, C1=0.
Please adjust E5 setting as below according to different ambient temperature range:
Ambient Temp(°C) E5 setting Other Setting 25 - 27 -01 NO change 22 - 24 0 NO change 19 - 21 1 NO change 15 - 18 2 NO change
Remark: The ambient temperature for this unit is better under 27 degree. If the ambient temperature is over 27
degree,the units can work,but the efciency of unit decline and the compressor is difcult to stop. The setting
for over 27 degrees is same as the range of 25-27 degree.
8
Page 9
Maintenance
1. Cabinet cleaning: The product should be cleaned once a week with the power supply disconnected. When cleaning, use mild rinsing water and non-corrosive detergent. Do not wash it directly under the faucet.
2. De-dust the condenser to clean. The condenser should be cleaned every three months with power supply disconnected. To clean the condenser, remove the dust on the bottom panel for air suction and remove the dust on the cooling fan of the condenser with wire brush or high pressure air gun.
3. Check for any leaks as well as oil stains. This will indicate that there is repair needed, to be performed by trained personnel.
4. Frequently observe the operation of the product. In case of abnormal noise, smell or smog, cut the power
supply immediately and call for a trained technician. Do not restart the product before the problem is xed.
5. Omcan Inc. will not be responsible for any accidents that occur because of failure to follow the regular maintenance.
SERVICE
To maintain good refrigeration performance, a refrigeration service person should be called periodically (at least twice a year) to clean the discharge honeycomb and remove any accumulated dirt from the
condenser coil and condensate evaporator pan on self-contained models. POOR CIRCULATION OF AIR THROUGH THE CONDENSER COIL WILL RESULT IN POOR REFRIGERATION PERFORMANCE.
Dirt accumulation inside the condensate evaporator pan will reduce the pan’s capacity and affect the efciency of the heater causing a burned out heater and an overow of defrost water onto the store oor.
Troubleshooting
Troubles Causes Solutions
Strange noise under the bottom shelf.
No refrigeration in spite of normal operation.
Weak air from curtain, and higher cabinet temperature.
Fan blade is broken. Power off and x the blade.
Unit off. Power on. Defrost process. Stop defrost cycle. Refrigerant leaking. Patch the leak and rell refrigerant. Unit failure. Call for professionals. Evaporator blocked by frost. Increase defrost frequency. Inside fan damaged. Replace the fan. Too low set point of temperature
controller. Vent blocked by storage. Remove the storage.
Adjust the set point.
9
Page 10
Troubleshooting
Normal air curtain, but higher cabinet temperature.
Evaporator Pan overowing. Heating pipe for evaporator pan is
Normal air curtain but periodical
uctuation of cabinet temperature.
Water leaks on oor. Ambient room temperature
Insufcient refrigerant. Rell the refrigerant.
Too high set point of temperature controllers.
The wind curtain is disturbed by
strong air ow.
Ambient temperature or humidity beyond standards.
damaged. Water-level controller failure. Replace the water-level controller. Ambient temperature or humidity
beyond standards. Condenser contaminated. Clean the condenser.
Poor venting of the unit. Improve the venting conditions. Heat protection of compressor
failure. Capillary is blocked by ice. Replace the drying lter. Temperature controller failure. Replace the temperature controller.
exceeds 75°F and 55% relative humidity.
Adjust the set point of the temperature controller.
Removing the disturbing factors.
Improve the conditions.
Replace the heating pipe.
Improve the conditions.
Replace the heat protection.
Connect appliance drain to oor
drain.
NOTE
The murmur of water is heard when the refrigerator is working. The coolant is circulating in the system. During wet seasons, condensation might be found on the outside of the refrigerator. This is caused by high humidity. Use a cloth to wipe it.
NOTE
The electric circuit diagram and parameters on the product name plate are nal ones. The design of
the machine may be improved without notice. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied persons in order to avoid hazard.
10
Page 11
Controller Instructions
Digital Temperature Controller
Front Panel Operation
1. Set temperature.
2. Press the “SET” button, the set temperature is displayed.
3. Press or buttons to modify and store the displayed value.
4. Press the “SET” button to exit the adjustment and display the cold-room temperature.
5. If no more buttons are pressed within 10 seconds, the cold-room temperature will be displayed.
6. Illumination: Press to light. Press again to stop.
7. Manual start/stop defrost: press button and hold for 6 seconds to defrost or stop defrost.
8. Refrigerant LED: During refrigeration, the LED is on; When the cold room temperature is constant, the LED
is off; During the delay start, the LED ashes.
9. Defrost LED: during defrosting, the LED is on; When it stops defrosting, the LED is off. During the delay display of defrost, the LED ashes.
Unauthorized modications and/or repairs;
Use of non original accessories or spare parts;
Exceptional events.
FEATURES OF FUNCTION
This temperature controller very reliable and durable. The relay is exclusively for the use of the compressor load which makes it safer. This way, the control of temperature easy to operate.
There is integrated intelligent control.
THE MAIN FEATURES
Temperature display (Celsius/Fahrenheit degrees).
Temperature control.
Illumination control.
Manual, automatic defrost by turning off.
Time or temperature setting to end defrost.
11
Page 12
Controller Instructions
The cold-room sensor temperature can lock during defrost.
Parameter sets and value storing.
Compressor restart delay.
Parameter locking.
The factory default resumption.
Offset on sensor temperature.
Self-testing.
SPECIFICATIONS
Power supply: approx. 12V, 50/60Hz.
Power consumption <5W.
Range of temperature displayed: -45° - 45°C (-40° - 120°F). Accuracy ±1°C (±2°F).
Range of set temperature: : -45° - 45°C (-40° - 120°F).
Temperature sensor: NTC, double sensors.
Output contact capacity for compressor: N.O. approx. 30A/250V, 50/60Hz.
Output contact capacity for illumination: N.O. approx. 30A/250V, 50/60Hz.
Main controller panel dimension: 78 × 35 × 76 mm.
Mounting dimension: 71 × 29 mm.
INDICATOR
Refrigerant: If the refrigerant LED is on, the compressor is working.
Constant temperature: If the refrigerant LED is off, the compressor stops.
Delay: If the refrigerant LED ashes, the compressor stops.
Defrost: If the defrost LED is on, the compressor stops.
FRONT PANEL OPERATION
Set temperature: Press “SET” button, the set temperature is displayed. Press the “UP” or “DOWN” buttons to modify and store the displayed value, press the “SET” button to exit the menu and display the cold-room
temperature.
Illumination: Press the “LIGHT” button, it lights. Press again, it stops.
Manual start/stop defrost: Press “LIGHT” button and hold for six (6) seconds to defrost or stop defrost.
Display the evaporator temperature: Press “UP” button and hold for six (6) seconds, the evaporator
temperature is displayed. After ten (10) seconds, the cold-room temperature is displayed.
PARAMETER SETUP
Setting the parameter: The parameter can be adjusted only after correct PA is entered. If wrong, the parameter can only be checked, but cannot be adjusted. However temperature controlling can still occur.
Setting parameter: Press “SET” for six (6) seconds, start the parameter menu and the PA (menu password) ashing. Enter the password by pressing “UP” or “DOWN”. Press “SET” again to choose the parameter. Press “UP” or “DOWN” and the parameter can be displayed and adjusted. After the change, if no button is
pressed in thirty (30) seconds, the system will set new parameter and go back to normal operations.
12
Page 13
Controller Instructions
Changing menu password (CPA): The CPA can be checked or changed only after correct menu password to be entered. When it shows CPA, press “UP” or “DOWN”, the present password is displayed and can be changed to new the new password. Press “LIGHT” to conrm and apply the new password. (Make sure to
remember the new password or you can never adjust another parameter).
Setting factory default parameters: Press “DOWN” button for one (1) second and then press “UP” button simultaneously for six (6) seconds, the indicator ashes. All parameters will be changed to factory defaults.
After ten (10) seconds, it returns to normal operation.
FUNCTION DETAILS
Parameter Function Set Range Default
Settings PA Menu Password Approx. 0 – 99 00° 00° E1 Lower Set Point Approx. -45°C Set
Temperature Approx. -40°F
E2 Higher Set Point Set Temperature
Approx. 45°C Approx. 120°F
E3 Temperature Hysteresis Approx. 00 – 10°C
Approx. 1 – 36°F E4 Compressor Start Delay Approx. 00 – 10 minutes 00° 0° E5 Offset On Room Temperature Approx. -5°C - 5°C / F 00° -1° E6 Offset On Evaporator Temperature Approx. -5°C - 5°C / F 00° 0° F1 Maximum Defrost Duration Approx. 1 – 60 minutes 20° 25° F2 Defrost Interval Time Approx. 00 – 24 hours 06° 4° F3 Defrost Termination Temperature Approx. 0 – 20°C
Approx. 32°F - 68°F F4 Display During Defrost 00 = normal display
01 = Last value before
defrost C1 Temperature Unit 00 = °C
01 = °F
CPA Changing Menu Password Approx. 00 – 90 (Setting
“00”, the menu password is
cancelled).
-15°C 05°F
10°C 50°F
05°C 07°C
12°C 54°F
01°
00°
00°
Recommended Settings
-5°
20°
Notes:
The parameters can be changed only after the correct PA is entered, or else it can only be checked. Temperature controlling can be changed without the correct PA.
PA is set “00”, no password required for checking and/or changing.
13
Page 14
Controller Instructions
PARAMETER DETAILS
Temperature controlling: After turning on for the delay time (E4), the compressor starts operating when
cold-room temperature is greater than the set temperature (set temperature + hysteresis), and will be off when cold-room temperature less than the set temperature. To protect the compressor, it can be restarted, unless the time when the compressor stops is longer than the delay time (E4).
Defrost by turning off: After a defrost interval, it begins automatic defrost function. Eg: When evaporator
sensor temperature is less than the defrost termination temperature (F3), the defrost LED is on and the compressor stops. When evaporator sensor is greater than the defrost termination temperature or defrost duration (F1) the defrost stops. After two (2) minutes of draining time, the cold-room temperature is greater than (set temperature + hysteresis) and the compressor starts. Tt goes back to refrigeration status. When
defrost interval time (F2) is set “00”, the function of automatic defrost will be cancelled. Temperature displayed when defrost: If F4 is set “01”, it displays the temperature when defrost starts. After defrost, it will continue to display this temperature for twenty (20) minutes and the defrost LED ashes, then come back
to normal temperature.
Sensory work mode: If the cold-room sensor is short circuited or overheated, “HH” is displayed. If the cold­room sensory has an open circuit or too low temperature, “LL” is displayed. The compressor automatically has a cycle of forty-ve (45) minutes on and fteen (15) minutes off. When the evaporator sensor fails or it
is over the displayed range, the defrost termination will be just controlled by the defrost duration.
NOTES FOR INSTALLATION
Before wiring, please read the instructions carefully and understand the function of every contact so that you can make correct wire connection. Control loads cannot exceed the ratings.
The temperature controller cannot be installed any area where there is water, dirt, moisture or high temperatures. Please pay attention to EMC problem and prevent the temperature controller from any
potentially dangerous contact.
The sensor cable leads must be kept away from the main supply in order to avoid a high frequency noise.
0.75 – 1.5 mm2 exible cord shall be used for wiring control load terminals.
The evaporator sensor must be installed between the ns of the evaporator in the area, where there is the
thickest ice. Do not place the evaporator sensor near the electric heater.
If the temperature controller stops functioning, please cut off the power supply and reset.
Please don’t dismantle the controller. If you need to repair or if there any problems when using the
controller, contact an authorized service center.
REFERENCE
Item Number Model Number Description Manufacturer Model Number
25825 RS-CN-0250
Refrigerated Showcase 250 L / 8.8 cu. ft.
110V/60/1 cETLus ETL Sanitation
RTS-250L
14
Page 15
Model RS-CN-0250 25825
Parts Breakdown
15
Page 16
Parts Breakdown
Model RS-CN-0250 25825
16
Page 17
Parts Breakdown
Model RS-CN-0250 25825
Item No. Description Position Item No. Description Position Item No. Description Position
79290 Power Cord for RTS-250L 1 79317 Connection Pipe for RTS-250L 28 79343 Right Glass for RTS-250L 54
79291 Line Bushing for RTS-250L 2 71562 Evaporator for RTS-250L 29 79344 Bottom Frame of Cabinet for RTS-250L 55
79292 Terminal for RTS-250L 3 79319 Dry Filter for RTS-250L 30 79345 Air Intake Grill for RTS-250L 56
79293 Feet Pad for RTS-250L 4 71654 Left Shelf Bracket for RTS-250L 31 79346 Wind Screen Strip for RTS-250L 57
79294 Feet for RTS-250L 5 79321 Bottom Shelf for RTS-250L 32 79347 Front Decorative Board for RTS-250L 58
79295 Magnet for RTS-250L 6 79322 Left Shelf Bracket for RTS-250L 33 60651 Curtain Hook for RTS-250L 59
60561 Rear Wheels for RTS-250L 7 79323 Top Shelf for RTS-250L 34 79349 Glass Deector for RTS-250L 60
79297
79298
79299 Base Board for RTS-250L 10 79326 Condenser Cover for RTS-250L 37 71564 Fan Guard for RTS-250L 63
79300 Left Panel of Base for RTS-250L 11 61222 Stands for Condenser for RTS-250L 38 61168 Cover of Circuit Board Box for RTS-250L 65
79301 Crossbar of Base for RTS-250L 12 79328 Night Curtain Bracket for RTS-250L 39 61167 Circuit Board Box for RTS-250L 66
79302 Back Cover of Base for RTS-250L 13 79329 Night Curtain for RTS-250L 40 79356 LED Transformer Holder for RTS-250L 67
79303 Water Receiver for RTS-250L 14 79330 Air-Out Board for RTS-250L 41
79304 Pipe for Evaporated Water for RTS-250L 15 79331 Back Clamp for RTS-250L 42 79358
79305 Water Level Detector for RTS-250L 16 79332 Honeycomb Panel for RTS-250L 43 79359 Cover of Junction Box for RTS-250L 70
79306 Compressor for RTS-250L 17 79333 Clamp for RTS-250L 44 61244 Junction Box for RTS-250L 71
63459 Hose Fitting for RTS-250L 18 79334 Top Front Cover for RTS-250L 45 79361 Right Panel of Base for RTS-250L 72
71517 Pipe Clip for RTS-250L 19 79335 Decorative Board for RTS-250L 46 30885 Digital Controller for RTS-250L 73
79309 Base Foam for Evaporator for RTS-250L 20 79336 Right Shelf Bracket for RTS-250L 47 71514 Switch for RTS-250L 74
79310 Left Glass for RTS-250L 21 71655 Right Shelf Bracket for RTS-250L 48 79364 Condenser Fan Motor for RTS-250L 75
79311 Front Decorative Strip for RTS-250L 22 79338 Price Tag Holder for RTS-250L 49 79365 Fan Guard for RTS-250L 76
79312 Nut Decoration for RTS-250L 23 79574 Top LED Light for RTS-250L 50-1 79366 Fan Blade for RTS-250L 77
79313 Nut Gasket for RTS-250L 24 79339 Shelf LED Light for RTS-250L 50-2 79368 Air Filter for RTS-250L 79
79314 Decoration Nut Gasket for RTS-250L 25 79340 Evaporator Cover for RTS-250L 51 79369 Ventilated Board of Base for RTS-250L 80
79315 Pole for Shelf for RTS-250L 26 79341
79316 Ventilated Board for RTS-250L 27 79342 Right Board of Evaporator for RTS-250L 53
Holder for Condenser Motor for RTS­250L
Condenser Motor Bracket Guard for RTS-250L
8 79324 Foam of Back Cover for RTS-250L 35 79367 Flat Net Cover for RTS-250L 61, 64, 78
9 79325 Condenser for RTS-250L 36 71565 Fan Blade for RTS-250L 62
79357 LED Transformer for RTS-250L 68
Left Board of Evaporator Cover for RTS-250L
Bracket of Circuit Board Box for RTS-250L
52
69
17
Page 18
Electrical Schematics
Model RS-CN-0250 25825
18
Page 19
Warranty Registration
Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at
the perforation and then send to the address specied below. You can also register online by visiting:
Merci d’avoir acheté un produit Omcan. Pour enregistrer votre garantie pour ce produit, complétez les informations ci-dessous, détachez la carte au niveau de la perforation, puis l’envoyer à l’adresse spécié ci-dessous. Vous pouvez également vous inscrire en ligne en visitant:
Gracias por comprar un producto Omcan usted. Para registrar su garantía para este producto, complete la información a continuación, cortar la tarjeta en la perforación y luego enviarlo a la dirección indicada a continuación. También puede registrarse en línea en:
https://omcan.com/warranty-registration/
For mailing in Canada
Pour postale au Canada
Por correo en Canadá
OMCAN
PRODUCT WARRANTY REGISTRATION
3115 Pepper Mill Court,
Mississauga, Ontario
Canada, L5L 4X5
PRODUCT WARRANTY REGISTRATION
4450 Witmer Industrial Estates, Unit 4,
For mailing in the US
Pour diffusion aux États-Unis
Por correo en los EE.UU.
OMCAN
Niagara Falls, New York
USA, 14305
or email to: service@omcan.com
Purchaser’s Information
Name: Company Name:
Address:
Telephone:
City: Province or State: Postal or Zip: Email Address:
Country: Type of Company:
Restaurant Bakery Deli
Dealer from which Purchased: Butcher Supermarket Caterer
Dealer City: Dealer Province or State: Institution (specify):
Invoice: Other (specify):
Model Name: Model Number: Serial Number:
Machine Description:
Date of Purchase (MM/DD/YYYY): Date of Installation (MM/DD/YYYY):
Would you like to extend the warranty? Yes No
Thank you for choosing Omcan | Merci d’avoir choisi Omcan | Gracias por elegir Omcan
19
Page 20
Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers. Today with partners in North America, Europe, Asia and South America, we continually work to improve
and grow the company. We strive to offer customers exceptional value through our qualied local sales
and service representatives who provide convenient access to over 5,000 globally sourced products.
Depuis 1951 Omcan a grandi pour devenir un des “leaders” de la distribution des équipements et matériel pour l’industrie des services alimentaires en Amérique du Nord. Notre succès au cours de ces nombreuses années peut être attribué à notre engagement à renforcer et à développer de nouvelles et existantes relations avec nos clients et les fabricants de valeur. Aujourd’hui avec des partenaires en Amérique du Nord, Europe, Asie et Amérique du Sud, nous travaillons continuellement à améliorer et développer l’entreprise. Nous nous efforçons d’offrir à nos clients une valeur exceptionnelle grâce à
nos ventes locales qualiées et des représentants de service qui offrent un accès facile à plus de 5000
produits provenant du monde entier.
Desde 1951 Omcan ha crecido hasta convertirse en un líder en la distribución de equipos y suministros de alimentos en América del Norte industria de servicios. Nuestro éxito en estos años se puede atribuir a nuestro compromiso de fortalecer y desarrollar nuevas relaciones existentes con nuestros valiosos clientes y fabricantes. Hoy con socios de América del Norte, Europa, Asia y América del Sur, que trabajan continuamente para mejorar y crecer la empresa. Nos esforzamos por ofrecer a nuestros clientes valor excepcional a través de nuestro local de ventas y representantes de los servicios que proporcionan un fácil acceso a más de 5,000 productos con origen a nivel mundial.
Loading...