Omcan BB-CN-0020-GH User Manual

Back Bar Bottle Coolers
Models BB-CN-0012-GH, 0012-SH, 0016-GH, 0016-SH, 0020-GH, 0020-SH
Items 50058, 50057, 50060, 50059, 50062, 50061
Revised - 12/06/2017
Toll Free: 1-800-465-0234
Fax: 905-607-0234
Email: service@omcan.com
www.omcan.com
Table of Contents
Model BB-CN-0012-GH / Model BB-CN-0016-GH / Model BB-CN-0020-GH
Model BB-CN-0012-SH / Model BB-CN-0016-SH / Model BB-CN-0020-SH
Section
General Information
Safety and Warranty
Technical Specications
Installation
Operation
Cleaning and Maintenance
--------------------------------------------------------------------------------------- 8 - 9
--------------------------------------------------------------------------------------- 9 - 12
--------------------------------------------------------------------------- 3 - 4
--------------------------------------------------------------------------- 4 - 6
-------------------------------------------------------------------------- 7
Page
--------------------------------------------------------------- 12 - 14
Parts Breakdown
Electrical Schematics
Warranty Registration
---------------------------------------------------------------------------- 15 - 19
---------------------------------------------------------------------- 20 - 22
---------------------------------------------------------------------------- 23
2
General Information
Omcan Manufacturing and Distributing Company Inc., Food Machinery of America, Inc. dba Omcan and Omcan Inc. are not responsible for any harm or injury caused due to any person’s improper or negligent use of this equipment. The product shall only be operated by someone over the age of 18, of
sound mind, and not under the inuence of any drugs or alcohol, who has been trained in the correct operation of this machine, and is wearing authorized, proper safety clothing. Any modication to the machine voids any warranty, and may cause harm to individuals using the machine or in the vicinity of the machine while in operation.
CHECK PACKAGE UPON ARRIVAL
Upon receipt of an Omcan shipment please inspect for external damage. If no damage is evident on the external packaging, open carton to ensure all ordered items are within the box, and there is no concealed damage to the machine. If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be
lled out within three days, from the delivery date shown in the shipping documents. Omcan has no recourse
for damaged products that were shipped collect or third party.
Before operating any equipment, always read and familiarize yourself with all operation and safety
instructions.
Omcan would like to thank you for purchasing this machine. It’s of the utmost importance to save these instructions for future reference. Also save the original box and packaging for shipping the
equipment if servicing or returning of the machine is required.
---------------------------------------------------------------------------------------------------------------------------------------------------
Omcan Fabrication et distribution Companie Limité et Food Machinery d’Amerique, dba Omcan et Omcan Inc. ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipement de façon irrégulière. Le produit ne doit être exploité que par quelqu’un de
plus de 18 ans, saine d’esprit, et pas sous l’inuence d’une drogue ou d’acohol, qui a été formé pour utiliser cette machine correctement, et est vêtu de vêtements de sécurité approprié. Toute modication
de la machine annule toute garantie, et peut causer un préjudice à des personnes utilisant la machine ou des personnes à proximité de la machine pendant son fonctionnement.
VÉRIFIEZ LE COLIS DÈS RÉCEPTION
Dès réception d’une expédition d’Omcan veuillez inspecter pour dommages externes. Si aucun dommage
n’est visible sur l’emballage externe, ouvrez le carton an de s’assurer que tous les éléments commandés
sont dans la boîte, et il n’y a aucun dommage dissimulé à la machine. Si le colis n’a subi aucune mauvaises manipulations, de bosses ou de dommages (visible ou cachée), notez-le sur le bond de livraison avant
d’accepter la livraison et contactez Omcan dans les 24 heures qui suivent, pour que nous puissions engager
une réclamation auprès du transporteur. Un rapport détaillé sur l’étendue des dommages causés à la machine
doit être rempli dans un délai de trois jours, à compter de la date de livraison indiquée dans les documents d’expédition. Omcan n’a aucun droit de recours pour les produits endommagés qui ont été expédiées ou cueilli
par un tiers transporteur.
3
General Information
Avant d’utiliser n’importe quel équipement, toujours lire et vous familiariser avec toutes les opérations et les consignes de sécurité.
Omcan voudrais vous remercier d’avoir choisi cette machine. Il est primordial de conserver ces
instructions pour une référence ultérieure. Également conservez la boîte originale et l’emballage pour
l’expédition de l’équipement si l’entretien ou le retour de la machine est nécessaire.
---------------------------------------------------------------------------------------------------------------------------------------------------
Omcan Empresa De Fabricacion Y Distribucion Inc. Y Maquinaria De Alimentos De America, Inc. dba Omcan y Omcan Inc. no son responsables de ningun daño o perjuicío causado por cualquier persona inadecuada o el uso descuidado de este equipo. El producto solo podra ser operado por una persona
mayor de 18 años, en su sano juicio y no bajo alguna inuencia de droga o alcohol, y que este ha sido entrenado en el correcto funcionamiento de esta máquina, y ésta usando ropa apropiada y autorizada. Cualquier modicación a la máquina anúla la garantía y puede causar daños a las personas usando la
máquina mientras esta en el funcionamiento.
REVISE EL PAQUETE A SU LLEGADA
Tras la recepcion de un envio Omcan favor inspeccionar daños externos. Si no hay daños evidentes en el empaque exterior, Habra el carton para asegurararse que todos los articulos solicitados ésten dentro de la caja y no encuentre daños ocultos en la máquina. Si el paquete ha sufrido un manejo de poco cuidado, golpes o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas, de modo que podamos iniciar una reclamación con la compañia. Un informe detallado sobre los daños causados a la máquina debe ser llenado en el plazo de tres días, desde la fecha de entrega que se muestra en los documentos de envío. Omcan no tiene ningun recurso por productos dañados que se enviaron
a recoger por terceros.
Antes de utilizar cualquier equipo, siempre lea y familiarizarse con todas las instrucciones de
funcionamiento y seguridad.
Omcan le gustaría darle las gracias por la compra de esta máquina. Es de la mayor importancia para salvar estas instrucciones para futuras consultas. Además, guarda la caja original y el embalaje para el
envío del equipo si servicio técnico o devolución de la máquina que se requiere.
Safety and Warranty
When using electrical appliances basic safety precautions should be followed:
This cooler must be properly installed and located in accordance with the installation service
representative.
Do not allow children to climb, stand or hang on the shelves in the cooler. They could damage the unit and
seriously injure themselves.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other
appliance.
4
Safety and Warranty
Unplug the unit from the electrical outlet before cleaning or making repairs.
Setting the temperature controls to the 0 (zero) position does not remove power to the light circuit,
perimeter heaters or evaporator fans.
NOTE: It is strongly recommended that any servicing be performed by an authorized instructions before it is used.
ELECTRICAL SAFETY
Do not under any circumstances cut or remove the grounding prong from the power cord. For safety this appliance must be properly grounded at all times.
The power cord of this cooler is equipped with a grounding plug which mates with a standard grounding
wall outlet to minimize the possibility of electric shock hazard.
If the outlet is a standard 2-prong outlet, it must be replaced with the properly grounded wall outlet. NEVER USE AN ADAPTER PLUG!
Have the wall outlet and circuit checked by a qualied electrician to make sure the outlet is properly
grounded. Check the incoming voltage with a voltmeter.
DO NOT USE EXTENSION CORDS. The use of extension cords to connect the cooler will void warranty. The unit must be close enough to the electrical supply so that extension cords are never used.
The cooler should always be plugged into its own dedicated circuit with a voltage rating that matches the rating plate. This provides the best performance and also prevents overloading wiring circuits which could become a re hazard from overheated wires.
Never unplug your cooler by pulling on the power cord. Always grip the plug rmly and pull straight out from
the outlet.
Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use a power cord that has cracks or abrasion damage along its length or at either of its ends.
When removing the cooler away from the wall be careful not to run over or damage the power cord.
When the cooler is installed or used, all the packaging (including carton and plastic wrap) should be
removed.
Keep the cooler stable to avoid vibration and noise.
The cooler should be installed in a place with good ventilation and a space of at least 6” should be allowed
between the surrounding walls and the cabinet wall for air circulation.
Unit should be placed far from any heating source to avoid decrease of refrigeration efciency.
Install the cooler in a dry place to prevent rust from forming on the compartment body, which may affect the
electrical insulation.
Service must only be performed by an authorized service representative, please call Omcan for a local
service company.
NOTE: Wiring diagram can be referenced by removing the front louvered grill, and looking on the inside
cabinet wall electrical supply so that extension cords are never used.
CAUTION
The cooler must be grounded correctly, never with a heating pipe and coal gas pipe.
5
Safety and Warranty
In case of damage to electrical cord and plug, please contact after sale service and never do it yourself.
When unplugging unit, please grasp by the plug, not the cord.
If the voltage is unstable, please select a suitable automatic voltage regulator.
If the power cuts off, you should wait for at least 5 minutes before turning on the unit again to avoid
damage to the compressor.
Never store any ammable, explosive or corrosive liquid or gas in or near the cooler.
PROPER DISPOSAL OF EQUIPMENT; DANGER! RISK OF CHILD ENTRAPMENT
Child entrapment and suffocation are not problems of the past. Junked or abandoned refrigerators are still
dangerous, even if they will sit for “just a few days.” If you are getting rid of an old refrigerator, please follow the
below instructions to help prevent a terrible accident.
Remove the doors.
Leave shelves in place to prevent children from easily climbing inside.
REFRIGERANT DISPOSAL
Your old refrigerator may have a cooling system that used “ozone depleting” chemicals. If you are throwing away your old refrigerator, be sure the refrigerant is removed for proper disposal by a qualied service technician. If you intentionally release any refrigerants you can be subject to nes and imprisonment under the
provisions of the environmental regulations.
1 YEAR PARTS AND LABOUR WARRANTY
Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized
service technician to repair the equipment locally.
Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not
improper use.
Please see www.omcan.com/warranty.html for complete info.
WARNING:
The packaging components are classied as normal solid urban waste and can therefore be disposed of without difculty.
In any case, for suitable recycling, we suggest disposing of the products separately (differentiated waste) according to the current norms.
DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!
6
Technical Specications
GLASS DOOR BOTTLE COOLERS
Model BB-CN-0012-GH BB-CN-0016-GH BB-CN-0020-GH Number of Doors 2 3 Temperature Range 33 - 41°F / 0.5 - 5°C Capacity 11.8 cu.ft. / 335 L 15.8 cu.ft. / 446 L 19.6 cu.ft. / 556 L Number of Shelves 4 6 Compressor HP 1/5 1/4+ Voltage 115V / 60Hz
Power 0.44 kW 0.46 kW 0.5 kW
Refrigerant R290 Isolation Material Cyclopentane Amps 2.88A 3.96A
Dimensions (DWH)
Interior Dimensions
Weight 271 lbs. / 123 kg. 326 lbs. / 148 kg. 355 lbs. / 161 kg. Item Number 50058 50060 50062
24.4” x 48.8” x 35.5”
620 x 1240 x 905mm
20” x 36.2” x 31”
508 x 920 x 787mm
24.4” x 60.75” x 35.5” 620 x 1544 x 905mm
20” x 48.2” x 31”
508 x 1224 x 787mm
24.4” x 72.75” x 35.5” 620 x 1848 x 905mm
20” x 60.2” x 31”
508 x 1529 x 787mm
SOLID DOOR BOTTLE COOLERS
Model BB-CN-0012-SH BB-CN-0016-SH BB-CN-0020-SH Number of Doors 2 3 Temperature Range 33 - 41°F / 0.5 - 5°C Capacity 11.8 cu.ft. / 335 L 15.8 cu.ft. / 446 L 19.6 cu.ft. / 556 L Number of Shelves 4 6 Compressor HP 1/5 1/4+ Voltage 115V / 60Hz
Power 0.44 kW 0.46 kW 0.50 kW
Refrigerant R290 Isolation Material Cyclopentane Amps 2.88A 3.96A
Dimensions (DWH)
Interior Dimensions
Weight 271 lbs. / 123 kg. 326 lbs. / 148 kg. 355 lbs. / 161 kg. Item Number 50057 50059 50061
24.4” x 48.8” x 35.5”
620 x 1240 x 905mm
20” x 36.2” x 31”
508 x 920 x 787mm
24.4” x 60.75” x 35.5” 620 x 1544 x 905mm
20” x 48.2” x 31”
508 x 1224 x 787mm
24.4” x 72.75” x 35.5” 620 x 1848 x 905mm
20” x 60.2” x 31”
508 x 1529 x 787mm
7
Installation
Tools required: Phillips screw driver.
Use a Phillips screw driver to remove the four (4) screws from the L-bracket connecting the unit to the wood skid. Then remove the L-bracket from the unit.
Remove skid by unscrewing all base rail anchor brackets. Place skid to the side.
Carefully upright cabinet.
When lifting unit do not use the counter top as a lifting point. Also remember to leave cabinet upright for 24-hours before plugging into power source.
Set unit in its nal location. Make sure there is adequate ventilation in this location. Under extreme heat conditions (+100°F / +38°C) an exhaust fan may be necessary.
Proper leveling of the unit is critical to operating success (for non-mobile models). Effective condensate
removal and door operation will be affected by leveling.
The cooler should be leveled front to back and side to side with a level.
Warning: Installation without proper ventilation will void the manufacturer’s warranty.
SEALING CABINET TO FLOOR
Step 1 - Position Cabinet
Allow six (6) inches between the wall and rear of the refrigerated bar equipment to assure proper ventilation.
Step 2 - Level Cabinet
Cabinet should be level side to side and front to back. Place a carpenter’s level in the interior cabinet oor in
four places:
A Position level in the inside oor of the unit near the door. Level should be parallel to cabinet front.
B Position level at the inside rear of cabinet. Level should be placed parallel to cabinet back.
C Perform similar procedures to steps A and B by placing the level on inside oor left and right sides parallel to the depth of the cooler. Level cabinet.
Step 3 - Applying Sealant
Draw an outline on the base of the oor.
Raise and block the front side of the cabinet.
Apply a bead of NSF Approved Sealant (see list below) to oor half an inch inside the outline drawn. The
bead must be heavy enough to seal the entire cabinet surface when it set down on the sealant.
Raise and block the rear of the cabinet.
Apply sealant on oor as outlined above on other 3 sides.
Examine to see that the cabinet is sealed to oor around entire perimeter.
8
Installation
NSF APPROVED SEALANTS:
Minnesota Mining #ECU800 Caulk.
Minnesota Mining #ECU2185 Caulk.
Minnesota Mining #ECU1055 Bead.
Minnesota Mining #ECU1202 Bead.
Armstrong Cork - Rubber Caulk.
Products Research Co #5000 Rubber Caulk.
GE Silicone Sealer.
Dow Corning Silicone Sealer.
NOTE: Asphalt oors are very susceptible to chemical attack. A layer of tape on the oor prior to applying the sealant will protect the oor.
Operation
START UP
Plug in the cooler and the compressor is ready to operate.
Temperature control set at #4 position gives the cooler an approximate temperature of 35°F. Allow unit to
function several hours, completely cooling cabinet before changing the control setting.
Excessive tampering with the control could lead to service difculties. Should it ever become necessary to
replace the temperature control it should be ordered from your dealer or recommended service agent.
Good air ow in your cooler is critical. Be careful to load product so that it neither presses against the back
wall nor comes within four (4) inches of the evaporator housing. Refrigerated air off the coil must circulate down the back wall.
LIGHT SWITCH LOCATION:
The switch is located on the front of the evaporator housing toward the right of the cabinet. Open the front
door.
NOTE: If the unit is disconnected or shut off, wait ve (5) minutes before re-starting unit.
RECOMMENDATION
Before loading product the unit should be run for 2 to 3 days. This allows conrmation that the electrical wiring
and installation are correct and no shipping damage has occurred. Remember that the factory warranty does not cover product loss.
9
Operation
REPLACEMENT PARTS
We maintains a record of the cabinet model number and serial number for your cooler. If at any time during
the life of your cooler a replacement part is needed, call the factory ofce with the model number and serial
number of your unit to place an order for the part.
CONTROLLER INSTRUCTIONS
Digital controller model: PJEZ for cooler
Display and functions
During normal operation, the controller displays the value of the probe set using parameter/4(=1 ambient
probe, default, = 2 second probe, = 3 third probe).In addition, the display has LEDs that indicate the activation of the control functions (see Table 1), while the 3 buttons can be used to activate/deactivate some of the functions(see Table 2).
LED’s and Associated Functions (Table 1)
Icon Function Normal Operation Start Up
ON OFF Blink Compressor On Off Request ON Fan On Off Request ON Defrost On Off Request ON Aux Output On Output Off - ON Alarm All No Alarm - ON Clock RTC tted and enabled, at
least 1 time band set
RTC not tted or disabled, not
even 1 time band set
- ON if RTC
tted
10
Table of Functions activated by the buttons - Models S, X, Y, C (Table 2)
Button Normal Operation Start Up
Pressing the Button Alone Pressed Together
Up ON/OFF
Down Defrost
Set Mute - 1 sec.: display/set the set
More than 3 sec: toggle ON/
OFF
More than 3 sec: start/stop
defrost
point.
- more than 3 secs.: access parameter setting menu (enter password )
- mute audible alarm (buzzer)
Start/Stop continuous cycle
- For 1 sec.
-
Pressed together Start parameter reset procedure
Setting the set point (desired temperature)
Operation
For 1 sec. display
rmware
vers. code
RESET cur­rent EZY set
• Press SET for 1 sec, the set value will start ashing after a few moments.
• Increase or decrease the value using UP or DOWN.
• Press SET to conrm the new value.
Switching the device ON/OFF
Press UP for more than 3 sec. The control and defrost algorithms are now disabled and the Instrument displays the message “OFF” alternating with the temperature read by the set probe.
Manual defrost
Press for DOWN more than 3 sec (the defrost starts only the temperature conditions are valid).
Continuous cycle
Press UP and DOWN together for more than 3 sec.
Access and setting type F (frequent) and type C (conguration) parameters
1. Press SET for 3 sec (the display will show “PS”).
2. • To access the type F and C parameter menu, enter the password “22” using UP/DOWN, press SET to
conrm.
• To access the F parameter menu only, press SET (without entering the password).
3. Scroll inside the parameter menu using UP/DOWN.
11
Operation
• To display/set the values of the parameter displayed, press SET, then UP/DOWN and nally SET to conrm the changes (returning to the parameter menu).
To save all the new values and exit the parameter menu, press SET for 3 sec. To exit the menu without saving the changed values (exit by timeout) do not press any button for at least 60
sec.
Mechanical Controller Instructions
OFF: shut the compressor off.
Temperature range from 7 (coldest) to 1 (warmest).
CAUTION: Setting the temperature control to the coldest setting may cause the
evaporator coil to freeze and ice up. This will eventually result in a warmer cabinet
temperature.
Cleaning and Maintenance
Condensers accumulate dirt and dust and require cleaning every 30 days. Dirty condensers result in
compressor failure, product loss, and lost sales -- which are not covered by warranty.
Air is pulled through the condenser continuously along with dust, lint, grease, etc. If you keep the condenser
clean you will minimize your service expense and lower your electrical costs. The condenser requires
scheduled cleaning every days or as needed. A dirty condenser can result in non-warranted part and compressor failures and product loss.
Proper cleaning involves removing debris from the condenser by using a soft brush or vacuuming the condenser with a shop vac or using Co2, nitrogen or pressurized air.
If you cannot remove the debris adequately please call you refrigeration service company.
On most of the reach-in units the condenser is accessible at the rear of the unit. You must remove the cabinet
grill to expose the condenser. The condenser looks like a group of vertical ns. You need to be able to see through the condenser for the unit to function at maximum capacity. Do not place lter material in front of condensing coil. This material blocks air ow to the coil which is similar to having a dirty coil.
CLEANING THE CONDENSER COIL
Required Tools:
Phillips screwdriver.
Stiff bristle brush.
12
Cleaning and Maintenance
Adjustable wrench
When using electrical appliances basic safety precautions should be followed:
Disconnect power to unit.
Take off lower grill assembly by removing all screws.
Remove bolts anchoring compressor assembly to frame rails and carefully slide out -- tube connections are exible.
Clean off accumulated dirt from condensing coil with the stiff bristle brush.
Lift cardboard cover above fan at plastic plugs and carefully clean condenser coil and fan blades.
After brushing condenser coil, vacuum dirt from coil and interior oor.
Replace cardboard cover, carefully slide compressor assembly back into position and replace bolts.
Reinstall louver assembly onto unit with appropriate fasteners and clips. Tighten all screws.
Connect unit to power and check to see if condenser is running.
STAINLESS STEEL CARE AND CLEANING
Recommended cleaners for stainless steel
Soap, ammonia and detergent medallion applied with a soft cloth or sponge for routine cleaning.
Arcal 20, Loc-O-Nu Ecoshine provide a barrier lm for ngerprints and smears.
Cameo, Talc, Zud First lmpression is for stubborn stains and discoloration. Rub in direction of polish lines.
Easy-off and De-Grease It oven aid are excellent for removals on all nishes for grease-fatty acids, blood
and burnt-on foods.
Any good commercial detergent can be applied with a sponge or soft cloth to remove grease and oil.
Benet, Super Sheen, Sheila Shine are good for restoration/passiveness.
CAUTION: Do not use any steel wool, abrasive or chlorine based products to clean stainless steel surfaces.
Stainless Steel Enemies
There are three basic items that can break down stainless steel’s passivity layer and allow corrosion to occur.
1. Scratches from wire brushes, metal scrapers and steel pads are just a few examples of items that can be abrasive to stainless steel’s surface.
2. Deposits left on stainless steel can leave spots. Hard water can leave spots. Hard water that is heated can
leave deposits if left to sit for too long. These deposits can cause the passive layer to break down and rust stainless steel. All deposits left from food prep or service should be removed as quickly as possible.
3. Chlorides are present in table salt, food and water. Household and industrial cleaners are the worst type of chlorides to use.
8 Steps that can help prevent rust on stainless steel
1. Use the correct cleaning tools. Use non-abrasive tools when cleaning your stainless steel products. The stainless steel’s passive layer will not be harmed by soft cloths and plastic scouring pads.
2. Clean along the polish lines. Polish lines or grain are visible on some stainless steel. Always scrub parallel
13
Cleaning and Maintenance
to visible lines. Use a plastic scouring pad or soft cloth when grain is not visible.
3. Use alkaline, alkaline chlorinated or non-chloride containing cleaners. While many traditional cleaners are loaded with chlorides, the industry is providing an ever increasing choice of non-chloride cleaners. If unsure of chloride content contact the cleaner supplier. If present cleaner contains chlorides, ask for an alternative.
Avoid cleaners containing quaternary salts as they can attack stainless steel causing pitting and rusting.
4. Water treatment. To reduce deposits, use soft water whenever possible. Installation of certain lters can be an advantage. Contact a treatment specialist about proper water treatment.
5. Maintain cleanliness of food equipment. Use cleaners at recommended strength(alkaline, alkaline
chlorinated or non-chloride). Avoid buildup of hard stains by cleaning frequently.
6. When using chlorinated cleaners you must rinse and wipe dry immediately. It is better to wipe standing cleaning agents and water as soon as possible. All stainless steel equipment to air dry. Oxygen helps maintain the passivity lm on stainless steel.
7. Hydrochloric acid (muriatic acid) should never be used on stainless steel.
8. Regularly restore/clean stainless steel.
KEG BEER LINE CLEANING
1. Tools needed.
2. Pour cleaning solution and water into the pump bottle and connect it to the beer line.
3. Place a bucket under the faucet and open the beer faucet. Pump to remove the cleaning solution and
water. Continue to pump until all cleaning solution has exited. You can also ll the line and let it soak then run through the line. After you have run the cleaning solution through, open the bottle and ll with water.
Repeat water rinsing until the line is free of cleaning chemicals.
REFERENCE
Item Number Model Number Description Manufacturer Model Number
50058 BB-CN-0012-GH
50060 BB-CN-0016-GH
50062 BB-CN-0020-GH
50057 BB-CN-0012-SH
50059 BB-CN-0016-SH
50061 BB-CN-0020-SH
Cooler Back Bar 11.8 cu ft Glass Door
115V/60/1 NSF ETL cETLus INTERTEK
Cooler Back Bar 15.8 cu ft Glass Door
115V/60/1 NSF ETL cETLus INTERTEK
Cooler Back Bar 19.6 cu ft Glass Door
115V/60/1 NSF ETL cETLus INTERTEK
Cooler Back Bar 11.8 cu ft Solid Door
115V/60/1 NSF ETL cETLus INTERTEK
Cooler Back Bar 15.8 cu ft Solid Door
115V/60/1 NSF ETL cETLus INTERTEK
Cooler Back Bar 19.6 cu ft Solid Door
115V/60/1 NSF ETL cETLus INTERTEK
UBB-24-48G-HC
UBB-24-60G-HC
UBB-24-72G-HC
UBB-24-48F-HC
UBB-24-60F-HC
UBB-24-72F-HC
14
Model BB-CN-0012-GH 50058 Model BB-CN-0016-GH 50060 Model BB-CN-0012-SH 50057 Model BB-CN-0016-SH 50059
Parts Breakdown
15
Parts Breakdown
Model BB-CN-0012-GH 50058 Model BB-CN-0012-SH 50057
Item No. Description Position Item No. Description Position Item No. Description Position
37682
37685
37686
37687
37688
37689
37690
37691
37693
37694
37696
37697
37698
37699
37700
Top Board for UBB-48G-HC, UBB­48F-HC
Inner Drain Pan for UBB-48G-HC, UBB-48F-HC
Evaporator for UBB-48G-HC, UBB­48F-HC
Fan Motor Installation Panel for UBB­48G-HC, UBB-48F-HC
Evaporator Fan Motor for UBB-48G-HC, UBB-48F-HC
Evaporator Fan Motor Holder for UBB­48G-HC, UBB-48F-HC
Blade of Evaporator Fan Motor for UBB­48G-HC, UBB-48F-HC
Evaporator Cover for UBB-48G-HC, UBB-48F-HC
Temperature Control Panel for UBB-48G­HC, UBB-48F-HC
Mechanical Thermostat for UBB-48G-HC, UBB-48F-HC
Temperature Control Knob for UBB-48G­HC, UBB-48F-HC
Light Switch for UBB-48G-HC, UBB­48F-HC
Frame for Machine Room for UBB-48G­HC, UBB-48F-HC
Compressor Unit Installation Board for UBB-48G-HC, UBB-48F-HC
Condenser for UBB-48G-HC, UBB­48F-HC
02 37701
03 37702
04 37703
05 37704 Starter for UBB-48G-HC, UBB-48F-HC 21 37731
06 37705
07 37706
08 37707
09 37708
10 37709
11M 37710
12 37715
13 37716
14 37721
15 37722
16 37727
Wiring Box for UBB-48G-HC, UBB­48F-HC
Start Capacitor for UBB-48G-HC, UBB­48F-HC
Overload Protector for UBB-48G-HC, UBB-48F-HC
Condenser Fan Motor for UBB-48G-HC, UBB-48F-HC
Outer Drain Pan for UBB-48G-HC, UBB-48F-HC
Lateral Cover of Machine Room for UBB­48G-HC, UBB-48F-HC
Front Cover of Machine Room for UBB­48G-HC, UBB-48F-HC
Left Glass Door for UBB-48G-HC, UBB-48F-HC
Left Solid Door for UBB-48G-HC, UBB­48F-HC
Glass Door Gasket for UBB-48G-HC, UBB-48F-HC
Solid Door Gasket for UBB-48G-HC, UBB-48F-HC
Right Glass Door for UBB-48G-HC, UBB-48F-HC
Right Solid Door for UBB-48G-HC, UBB-48F-HC
Bottom Right Hinge for Glass Door for UBB-48G-HC, UBB-48F-HC
18 37728
19 37729
20 37730
22 37732
23 37733
26 37734
27 37735
28 37736
28 37737 Shelf for UBB-48G-HC, UBB-48F-HC 41
29 37741
29 28236
30 78353 Door Handle for UBB-48G-HC 46
30 78354
32
Bottom Right Hinge for Solid Door for UBB-48G-HC, UBB-48F-HC
Bottom Left Hinge for Glass Door for UBB-48G-HC, UBB-48F-HC
Bottom Left Hinge for Solid Door for UBB-48G-HC, UBB-48F-HC
Upper Right Hinge for UBB-48G-HC, UBB-48F-HC
Upper Left Hinge for UBB-48G-HC, UBB-48F-HC
Plate of Lock for Left Door for UBB-48G­HC, UBB-48F-HC
Plate of Lock for Right Door for UBB­48G-HC, UBB-48F-HC
Fixed Block for Worktop for UBB-48G­HC, UBB-48F-HC
K Strip - 4 Holes for UBB-48G-HC, UBB-48F-HC
LED Light for UBB-48G-HC, UBB­48F-HC
Adjusted Feet for UBB-48G-HC, UBB­48F-HC
Door Handle Plastic Gasket for UBB­48G-HC, UBB-48F-HC
32
33
33
34
35
36
37
38
39
42
45
47
16
Parts Breakdown
Model BB-CN-0016-GH 50060 Model BB-CN-0016-SH 50059
Item No. Description Position Item No. Description Position Item No. Description Position
37683
37685
37686
37687
37688
37689
37690
37691
37693
37694
37696
37697
37698
37699
37700
Top Board for UBB-60G-HC, UBB­60F-HC
Inner Drain Pan for UBB-60G-HC, UBB-60F-HC
Evaporator for UBB-60G-HC, UBB­60F-HC
Fan Motor Installation Panel for UBB­60G-HC, UBB-60F-HC
Evaporator Fan Motor for UBB-60G-HC, UBB-60F-HC
Evaporator Fan Motor Holder for UBB­60G-HC, UBB-60F-HC
Blade of Evaporator Fan Motor for UBB­60G-HC, UBB-60F-HC
Evaporator Cover for UBB-60G-HC, UBB-60F-HC
Temperature Control Panel for UBB-60G­HC, UBB-60F-HC
Mechanical Thermostat for UBB-60G-HC, UBB-60F-HC
Temperature Control Knob for UBB-60G­HC, UBB-60F-HC
Light Switch for UBB-60G-HC, UBB­60F-HC
Frame for Machine Room for UBB-60G­HC, UBB-60F-HC
Compressor Unit Installation Board for UBB-60G-HC, UBB-60F-HC
Condenser for UBB-60G-HC, UBB­60F-HC
02 37701
03 37702
04 37703
05 37704 Starter for UBB-60G-HC, UBB-60F-HC 21 37731
06 37705
07 37706
08 37707
09 37708
10 37711
11M 37712
12 37717
13 37718
14 37723
15 37724
16 37727
Wiring Box for UBB-60G-HC, UBB­60F-HC
Start Capacitor for UBB-60G-HC, UBB­60F-HC
Overload Protector for UBB-60G-HC, UBB-60F-HC
Condenser Fan Motor for UBB-60G-HC, UBB-60F-HC
Outer Drain Pan for UBB-60G-HC, UBB-60F-HC
Lateral Cover of Machine Room for UBB­60G-HC, UBB-60F-HC
Front Cover of Machine Room for UBB­60G-HC, UBB-60F-HC
Left Glass Door for UBB-60G-HC, UBB-60F-HC
Left Solid Door for UBB-60G-HC, UBB­60F-HC
Glass Door Gasket for UBB-60G-HC, UBB-60F-HC
Solid Door Gasket for UBB-60G-HC, UBB-60F-HC
Right Glass Door for UBB-60G-HC, UBB-60F-HC
Right Solid Door for UBB-60G-HC, UBB-60F-HC
Bottom Right Hinge for Glass Door for UBB-60G-HC, UBB-60F-HC
18 37728
19 37729
20 37730
22 37732
23 37733
26 37734
27 37735
28 37736
28 37738 Shelf for UBB-60G-HC, UBB-60F-HC 41
29 37741
29 28236
30 78353 Door Handle for UBB-60G-HC 46
30 78354
32
Bottom Right Hinge for Solid Door for UBB-60G-HC, UBB-60F-HC
Bottom Left Hinge for Glass Door for UBB-60G-HC, UBB-60F-HC
Bottom Left Hinge for Solid Door for UBB-60G-HC, UBB-60F-HC
Upper Right Hinge for UBB-60G-HC, UBB-60F-HC
Upper Left Hinge for UBB-60G-HC, UBB-60F-HC
Plate of Lock for Left Door for UBB-60G­HC, UBB-60F-HC
Plate of Lock for Right Door for UBB­60G-HC, UBB-60F-HC
Fixed Block for Worktop for UBB-60G­HC, UBB-60F-HC
K Strip - 4 Holes for UBB-60G-HC, UBB-60F-HC
LED Light for UBB-60G-HC, UBB­60F-HC
Adjusted Feet for UBB-60G-HC, UBB­60F-HC
Door Handle Plastic Gasket for UBB­60G-HC, UBB-60F-HC
32
33
33
34
35
36
37
38
39
42
45
47
17
Parts Breakdown
Model BB-CN-0020-GH 50062 Model BB-CN-0020-SH 50061
18
Parts Breakdown
Model BB-CN-0020-GH 50062 Model BB-CN-0020-SH 50061
Item No. Description Position Item No. Description Position Item No. Description Position
37684
37685
37686
37687
37804
37688
37689
37690
37692
37693
37694
37696
37697
37698
37699
Top Board for UBB-72G-HC, UBB­72F-HC
Inner Drain Pan for UBB-72G-HC, UBB-72F-HC
Evaporator for UBB-72G-HC, UBB­72F-HC
Fan Motor Installation Panel for UBB­72G-HC, UBB-72F-HC
Fan Motor Installation Panel for UBB­72G-HC, UBB-72F-HC
Evaporator Fan Motor for UBB-72G-HC, UBB-72F-HC
Evaporator Fan Motor Holder for UBB­72G-HC, UBB-72F-HC
Blade of Evaporator Fan Motor for UBB­72G-HC, UBB-72F-HC
Evaporator Cover for UBB-72G-HC, UBB-72F-HC
Temperature Control Panel for UBB-72G­HC, UBB-72F-HC
Mechanical Thermostat for UBB-72G-HC, UBB-72F-HC
Temperature Control Knob for UBB-72G­HC, UBB-72F-HC
Light Switch for UBB-72G-HC, UBB­72F-HC
Frame for Machine Room for UBB-72G­HC, UBB-72F-HC
Compressor Unit Installation Board for UBB-72G-HC, UBB-72F-HC
02 37700
03 37701
04 37702
05 37703
05 37704 Starter for UBB-72G-HC, UBB-72F-HC 21 37731
06 37705
07 37706
08 37707
09 37708
10 37713
11M 37714
12 37719
13 37720
14 37725
15 37726
Condenser for UBB-72G-HC, UBB­72F-HC
Wiring Box for UBB-72G-HC, UBB­72F-HC
Start Capacitor for UBB-72G-HC, UBB­72F-HC
Overload Protector for UBB-72G-HC, UBB-72F-HC
Condenser Fan Motor for UBB-72G-HC, UBB-72F-HC
Outer Drain Pan for UBB-72G-HC, UBB-72F-HC
Lateral Cover of Machine Room for UBB­72G-HC, UBB-72F-HC
Front Cover of Machine Room for UBB­72G-HC, UBB-72F-HC
Left Glass Door for UBB-72G-HC, UBB-72F-HC
Left Solid Door for UBB-72G-HC, UBB­72F-HC
Glass Door Gasket for UBB-72G-HC, UBB-72F-HC
Solid Door Gasket for UBB-72G-HC, UBB-72F-HC
Right Glass Door for UBB-72G-HC, UBB-72F-HC
Right Solid Door for UBB-72G-HC, UBB-72F-HC
16 37727
18 37728
19 37729
20 37730
22 37732
23 37733
26 37734
27 37735
28 37736
28 37739 Shelf for UBB-72G-HC, UBB-72F-HC 41
29 37740
29 78353 Door Handle for UBB-72G-HC
30
30
Bottom Right Hinge for Glass Door for UBB-72G-HC, UBB-72F-HC
Bottom Right Hinge for Solid Door for UBB-72G-HC, UBB-72F-HC
Bottom Left Hinge for Glass Door for UBB-72G-HC, UBB-72F-HC
Bottom Left Hinge for Solid Door for UBB-72G-HC, UBB-72F-HC
Upper Right Hinge for UBB-72G-HC, UBB-72F-HC
Upper Left Hinge for UBB-72G-HC, UBB-72F-HC
Plate of Lock for Left Door for UBB-72G­HC, UBB-72F-HC
Plate of Lock for Right Door for UBB­72G-HC, UBB-72F-HC
Fixed Block for Worktop for UBB-72G­HC, UBB-72F-HC
K Strip - 4 Holes for UBB-72G-HC, UBB-72F-HC
Middle Shelf for UBB-72G-HC, UBB­72F-HC
32
32
33
33
34
35
36
37
38
39
42
19
Electrical Schematics
Model BB-CN-0012-GH 50058 Model BB-CN-0012-SH 50057
20
Model BB-CN-0016-GH 50060 Model BB-CN-0016-SH 50059
Electrical Schematics
21
Electrical Schematics
Model BB-CN-0020-GH 50062 Model BB-CN-0020-SH 50061
22
Warranty Registration
Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specied below. You can also register online by visiting:
Merci d’avoir acheté un produit Omcan. Pour enregistrer votre garantie pour ce produit, complétez les informations ci-dessous, détachez la carte au niveau de la perforation, puis l’envoyer à l’adresse spécié ci-dessous. Vous pouvez également vous inscrire en ligne en visitant:
Gracias por comprar un producto Omcan usted. Para registrar su garantía para este producto, complete la información a continuación, cortar la tarjeta en la perforación y luego enviarlo a la dirección indicada a continuación. También puede registrarse en línea en:
www.omcan.com/warrantyregistration.html
For mailing in Canada
Pour postale au Canada
Por correo en Canadá
OMCAN
PRODUCT WARRANTY REGISTRATION
3115 Pepper Mill Court,
Mississauga, Ontario
Canada, L5L 4X5
PRODUCT WARRANTY REGISTRATION
4450 Witmer Industrial Estates, Unit 4,
For mailing in the US
Pour diffusion aux États-Unis
Por correo en los EE.UU.
OMCAN
Niagara Falls, New York
USA, 14305
or email to: service@omcan.com
Purchaser’s Information
Name: Company Name:
Address:
Telephone:
City: Province or State: Postal or Zip: Email Address:
Country: Type of Company:
Restaurant Bakery Deli
Dealer from which Purchased: Butcher Supermarket Caterer
Dealer City: Dealer Province or State: Institution (specify):
Invoice: Other (specify):
Model Name: Model Number: Serial Number:
Machine Description:
Date of Purchase (MM/DD/YYYY): Date of Installation (MM/DD/YYYY):
Would you like to extend the warranty? Yes No
Thank you for choosing Omcan | Merci d’avoir choisi Omcan | Gracias por elegir Omcan
23
Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers. Today with partners in North America, Europe, Asia and South America, we continually work to improve
and grow the company. We strive to offer customers exceptional value through our qualied local sales
and service representatives who provide convenient access to over 3, 500 globally sourced products.
Depuis 1951 Omcan a grandi pour devenir un des “leaders” de la distribution des équipements et matériel pour l’industrie des services alimentaires en Amérique du Nord. Notre succès au cours de ces nombreuses années peut être attribué à notre engagement à renforcer et à développer de nouvelles et existantes relations avec nos clients et les fabricants de valeur. Aujourd’hui avec des partenaires en Amérique du Nord, Europe, Asie et Amérique du Sud, nous travaillons continuellement à améliorer et développer l’entreprise. Nous nous efforçons d’offrir à nos clients une valeur exceptionnelle grâce à
nos ventes locales qualiées et des représentants de service qui offrent un accès facile à plus de 3500
produits provenant du monde entier.
Desde 1951 Omcan ha crecido hasta convertirse en un líder en la distribución de equipos y suministros de alimentos en América del Norte industria de servicios. Nuestro éxito en estos años se puede atribuir a nuestro compromiso de fortalecer y desarrollar nuevas relaciones existentes con nuestros valiosos clientes y fabricantes. Hoy con socios de América del Norte, Europa, Asia y América del Sur, que trabajan continuamente para mejorar y crecer la empresa. Nos esforzamos por ofrecer a nuestros clientes valor excepcional a través de nuestro local de ventas y representantes de los servicios que proporcionan un fácil acceso a más de 3, 500 productos con origen a nivel mundial.
Loading...