Olympus X-Press V, StarTip V User Manual

Single Use Cannula V
Single Use Cannula V
Taper (PR-V435Q)
Standard (PR-V416Q)
Short taper (PR-V418Q)
Ball Tip (PR-V223Q)
Taper (PR-V434Q)
Short taper (PR-V414Q)
Long taper (PR-V420Q)
The V-System is a complete system that integrates Olympus endoscopes and EndoTherapy devices. The revolutionary V-System design offers the option of guidewire manipulation by the physician or the assistant, allows easier exchange of catheters, and enhances cannulation capability.
The convenient C-Hook allows the device handle to be attached to the endoscope’s control section, putting it within easy reach of the endoscopist. With the device handle right at hand, the endoscopist can maneuver the guidewire, inject contrast media, and manipulate the handle — all while keeping a grip on the scope control section.
The exclusive V-Marking is located on the proximal side of the sheath. When this marking reaches the channel port on the scope’s control section, it indicates that the device tip has reached the distal end of the scope and the V-Groove forceps elevator may be lowered. When withdrawing the device from the scope, the same marking indicates when to raise the elevator to lock the guidewire.
C-Hook
Now endoscopists have the option to manipulate guidewires and devices.
V-Marking
Indicates when to raise and lower the V-Groove forceps elevator.
The Innovative V-System Design Lets You Proceed with Confidence and Efficiency
The Innovative V-System Exchange Capability Makes Olympus' ERCP Cannulae Even More Efficient
Excellent visibility under fluoroscopy
The platinum marking at the distal end ensures that the tip is clearly visible under fluoroscopy.
Wide selection of cannulae
A full line-up of 8 models of different tip designs and diameters is available to meet every clinical requirement.
Smooth cannulation of even minor or constricted papilla
The X-PressV’s cross-cut round tip is not only ideally suited for smooth cannulation of the papilla of Vater, but is also equally effective for cannulation of the minor or constricted papilla.
Expanded guidewire compatibility
Compatible with guidewires of various sizes.
Comprehensive distal marking system
Cannulation depth is indicated by markings at 3mm intervals at the distal end.
Single-use design for convenience and reliability
All the cannulae in this line are designed for single use only.
Standard position of
X-PressV cannula
During guidewire
insertion or fluid injection
Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer.
Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan
Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-18, 20097 Hamburg, Germany
6100 Blue Lagoon Drive, Suite 390 Miami, Florida 33126-2087, U.S.A
Keymed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, England
491B River Valley Road #12-01/04,Valley Point Office Tower,Singapore 248373
Room 1520-1527, Ocean Centre, 5 Canton Road, Tsimshatsui, Kowloon, Hong Kong
Room.1401, East Tower, Gong Yuan No6 Royal Palace, No6 Gon YuanXijie, JianGuoMenNei, DongCheng District, Beijing, 100005, China
117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, Russia
31 Gilby Road, Mount Waverley, VIC., 3149, Australia
2 Corporate Center Drive, Melville, N.Y. 11747-3157, U.S.A.
Spacifications
Model Distal tip diameter Portion DiameterShape of the distal end
1700mm
Working length Compatible guidewire
PR-V414Q
PR-V416Q
PR-V418Q
PR-V420Q
PR-V427Q
PR-V434Q
PR-V435Q
PR-V223Q
2.1mm
2.0mm
1950mm
0.89mm(0.035inch)
0.89mm(0.035inch)
0.64mm(0.025inch)
0.64mm(0.025inch)
0.89mm(0.035inch)
0.89mm(0.035inch)
0.64mm(0.025inch)
0.89mm(0.035inch)
Short taper
Standard
Short taper
Long taper
Slit
Taper
Taper
Ball Tip
4.5Fr
4.0Fr
3.5Fr
3.5Fr
2.5Fr
4.0Fr
3.5Fr
6.0Fr
Printed in Japan F1086SB-3-0804
Single Use 3-Lumen Extraction Balloon V
B
The guidewire and injection lumens are separated to ensure smoother passage of the guidewire. Additionally, contrast media can be injected without removing the guidewire. Two models are available — one with the injection port located above the balloon and the other with the injection port located below the balloon.
Triple-lumen design allows for easy passage of the guidewire
The balloon catheter sheath is manufactured from a special material that allows it for improved insertion into the papilla, ensuring smoother guidewire passage, and facilitating contrast injection. The tapered design — 7 Fr. catheter at the proximal end tapers to 5 Fr. at the distal end — enables an easy approach to the bile duct and accommodates a 0.035" guidewire.
Easier cannulation and tapered sheath design
Multiple balloon sizing
Injection Lumen
0.035" Guidewire Lumen
Air Lumen
The balloon can be inflated to one of three diameters— 8.5mm,
11.5mm, and 15mm. The balloon size can be easily adjusted to suit the requirements and conditions of each case so there is no need to change catheters during the procedure.
Reliable, Efficient Stone Extraction with the Multi-Size Balloon Design, Th Manufactured from a Special Material That Allows for Easier Cannulation,
Tr iple Lumen, Multi Size Balloon with Revolutionary V-System Exchange Capability for More Precise Balloon Inflation and Efficient Stone Extraction
V-Marking
The exclusive V-Marking is located on the proximal side of the sheath. When this marking reaches the channel port on the scope’s control section, it indicates that the device tip has reached the distal end of the scope and the V-Groove forceps elevator may be lowered. When withdrawing the device from the scope, the same marking indicates when to raise the elevator to lock the guidewire.
The V-System is a complete system that integrates Olympus endoscopes and EndoTherapy devices. The revolutionary V-System design offers the option of guidewire manipulation by the physician or the assistant, allows easier exchange of catheters, and enhances cannulation capability.
The V-Sheath allows the endoscopist complete device control or, if preferred, device control may be given to the assistant. The unique device design allows the guidewire sheath and injection sheath/handle to be separated. This forked sheath design allows either the endoscopist or the assistant to control the device.
V-Sheath
The Innovative V-System Design Lets You Proceed with Confidence and Efficiency
V-System device replacement procedure
C-Hook
The convenient C-Hook allows the device handle to be attached to the endoscope’s control section, putting it within easy reach of the endoscopist. With the device handle right at hand, the endoscopist can maneuver the guidewire, inject contrast media, and manipulate the handle — all while keeping a grip on the scope control section.
Indicates when to raise and lower the V-Groove forceps elevator.
Device control by the endoscopist or the assistant.
Confirm the position of the V-Marking
on the V-System EndoTherapy accessory.
Now endoscopists have the option to manipulate guidewires and devices.
When the V-Marking is completely visible
above the instrument channel port, lift the
forceps elevator to lock the guidewire.
The guidewire is now locked
into the V-Groove.
Completely remove the device.
B
The guidewire and injection lumens are separated to ensure smoother passage of the guidewire. Additionally, contrast media can be injected without removing the guidewire. Two models are available — one with the injection port located above the balloon and the other with the injection port located below the balloon.
Triple-lumen design allows for easy passage of the guidewire
The balloon catheter sheath is manufactured from a special material that allows it for improved insertion into the papilla, ensuring smoother guidewire passage, and facilitating contrast injection. The tapered design — 7 Fr. catheter at the proximal end tapers to 5 Fr. at the distal end — enables an easy approach to the bile duct and accommodates a 0.035" guidewire.
Easier cannulation and tapered sheath design
Dual radiopaque bands for position confirmation
The 15mm syringe also has markings at 8.5mm and 11.5mm. This makes it possible to inflate to three balloon sizes using only one syringe.(This is not pre-measured)
Three pre-measured syringes for reliable inflation
Multiple balloon sizing
Injection Lumen
0.035" Guidewire Lumen
Air Lumen
For easy confirmation of balloon position during fluoroscopy, two radiopaque bands are incorporated — one at the distal end of the balloon and one at the proximal end.
Three pre-measured, clearly marked syringes enable precise inflation of each balloon to the desired size. Much easier and much more reliable than using a single syringe with different markings, the pre-measured syringes allow inflation of the balloon quickly and accurately without having to visually check the markings on the syringe.
The balloon can be inflated to one of three diameters— 8.5mm,
11.5mm, and 15mm. The balloon size can be easily adjusted to suit the requirements and conditions of each case so there is no need to change catheters during the procedure.
Reliable, Efficient Stone Extraction with the Multi-Size Balloon Design, Three Pre-Measured Syringes, and The Sheath is Manufactured from a Special Material That Allows for Easier Cannulation, Exchange and Injection of Contrast Media.
Tr iple Lumen, Multi Size Balloon with Revolutionary V-System Exchange Capability for More Precise Balloon Inflation and Efficient Stone Extraction