MULTI-PAIR UNSHIELDED CABLE
CONDUCTOR SIZE
24 AWG
OF
PAIRS
1
30772 89 2602
30793 89 2603
3078
4 89912604
3604 M5U
PG.
NO.P/N
89
22 AWG
2002
2002L
2002T
2365
2366
2380
2601
3130
2702
2703
2704
PG.
NO.P/N
20 AWG
31
2367
28
2781
29
2781T
22
3131
22
24
44
72
44
44
44
2783 45 2803 45
44
44
44
PG.
NO.P/N
CABLE SELECTOR
GUIDE
18 AWG
PG.
NO.P/N
22
31
29
72
2202
2202L
2202T
2370
2801
3106L
3132
3752-725
3752-760
2802 45
2804 45
45
28
29
22
45
25
72
29
27
16 AWG
2302
2302L
2302T
2372
2373
3112L
3133
3758-760
PG.
NO.P/N
14 AWG
PG.
NO.P/N
45
2342
28
2342L
29
2342T
22
3118L
22
3134
25
3784-760A
72
27
33
28
29
25
72
27
12 AWGNO.
2362
2362L
2362T
3122L
3122T
3135
PG.
NO.P/N
33
28
29
25
27
72
30806 89 2606
9 2609
11 2611 44
308112 89 2712
13 2613 44
15 2615
19 2619
23 2623
25 CF
3056
3083
3625 M5E
27 2627
308550 89 2627
308675 89
3087100 89 6978 89
89
91
2706
6973
2709
6974
2715
2719
2723
6976 89
2727
2727
6977
44
2786 45 2806 45
44
89
44
2789 45 2809 45
44
44
89
44
2795 45 2815 45
44
44
44
44
44
44
44
44
44
89
2812 45
2819 45
4
173010_olympic_catalog_2017_v9.indd 4 6/26/17 10:31 AM
PLENUM
FIRE ALARM CABLE
NEC: FPLP
-70°C +200°C 300 VOLTS
OLYMPIC
NO. STRAND
Shielded
3762ET
Description: Solid Bare Copper, FEP
Insulated, Twisted into Pairs, Overall
Aluminum Mylar Shield, Stranded Tinned
Copper Drain Wire, Red FEP Jacket.
COLOR CODE: Black & red, White & green
UL CLASSIFIED FPLP, CMP, CL3P
Unshielded
3774ET
3782ET
3783ET
3760ET
3119EST
3124ET
OLYMPIC
NO. STRAND
NYC PLENUM FIRE ALARM CABLE
PAIRS
1
2
1
2
1
2
1
300 VOLTS
NO. OF
COND. AWG
CONDUCTOR
AWG
18
18
16
16
14
14
12
NOM.
O.D.
1
1
1
1
1
1
1
.215”
.325”
.240”
.360”
.265”
.405”
.300”
NOM.
CAP.
24
19
28
22
32
25
36
PLENUM FIRE ALARM CABLE
CONDUCTOR
NOM.
O.D.
FPLP
DESCRIPTION:
Solid soft bare copper, insulated with
extruded insulation, twisted, overall red jacket
† FPLP, CL3P only
Shielded
FPLP
DESCRIPTION:
Solid soft bare copper, insulated with
extruded insulation, twisted, aluminum
mylar shield, tinned copper drain wire,
overall red jacket
COLOR CODE:
Black, Red, White, Green
† FPLP, CL3P only
3752-760
*3754-760
3758-760
*3757-760
†
3784-760A
†
3119T
†
3122T
†
3123T
OLYMPIC
NO. STRAND
3762-760
3774-760
3782-760
3783-760
†
3760-760
†
*3119ST
†
3124T
2
4
2
4
2
4
2
4
NO. OF
COND. AWG
2
4
2
4
2
4
2
18
18
16
16
14
14
12
12
CONDUCTOR
18
18
16
16
14
14
12
*Color Code: Black, Red, Brown, Blue
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
.139”
.172”
.160”
.189”
.210”
.247”
.245”
.290”
NOM.
O.D.
.146”
.171”
.167”
.196”
.193”
.245”
.250”
27
173010_olympic_catalog_2017_v9.indd 27 6/26/17 10:31 AM