Olympic Wire and Cable DIESEL LOCOMOTIVE CAR WIRE, SWITCHBOARD WIRE Catalog Page

RoHS Compliant
DIESEL LOCOMOTIVE
CAR WIRE
-40°C+ 90°C-600/2000 VOLTSINDUSTRIAL MOTOR LEAD CABLE
DESCRIPTION:
Nominal Voltage: RHH/RHW-2 600V and 200V, RW-90 CSA, 1kV, DLO 2kV
Conductors: Flexible strand tin coated copper conductor, B-172, ASTM B-33
Separator: Tape separator between conductor and insulation
Insulation: Ethylene-propylene rubber (EPR), UL, CSA, ICEA, AAR RP-588, 90˚C
Jacket: Black heavy duty, thermoset CPE, ICEA S-95-658 NEMA WC70, AAR RP-586
Bending Radius: For fixed – minimum 4xD, for flexible – minimum 6xD, D – diameter of cable
APPLICATIONS:
For use in diesel and electric locomotives, transit cars, earth-moving equipment, and oil rigging
APPROVALS:
UL: (CPE Jacket) RHW-2 90C wet and dry, VW-1, Sun Resistant, for 1/0 and larger ST-1, FT-4, IEEE1202,for CT use
C(UL): TYPE RW90 EPR; 1000V; FT1
CSA: RW-90 90C; FT1; FT4; -40˚C; for 1/0 AWG
and larger; OIL RES, Tray Cable, Sun Resistant
MSHA
OLYMPIC
NO.
8032
8033
8034
8035
8036
8038
8040
8041
8042
8043
8044
8045
8046
8047
8048
8049
8050
8051
8052
CONDUCTOR NOM.
AWG NO. STRANDS
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
313.1 MCM
444.4 MCM
535.3 MCM
646.4 MCM
777.7 MCM
929.2 MCM
1111 MCM
19
19
27
37
61
105
150
225
275
325
450
550
775
1100
1325
1591
1924
2299
2750
INSULATION
THICKNESS
.045”
.045”
.045”
.060”
.060”
.060”
.060”
.080”
.080”
.080”
.080”
.080”
.094”
.094”
.109”
.109”
.109”
.109”
.125”
JACKET
THICKNESS
.030”
.030”
.030”
.030”
.030”
.030”
.030”
.045”
.045”
.045”
.045”
.045”
.065”
.065”
.065”
.065”
.065”
.065”
.095”
O.D.
.193”
.217”
.248”
.323”
.362”
.413”
.489”
.583”
.642”
.681”
.781”
.815”
.984”
1.138”
1.244”
1.355”
1.433”
1.516”
1.791”
CSA CL1251, AWM I A/B
OSHA ACCEPTABLE VW-1 RATED
DESCRIPTION:
Stranded tinned copper conductor, separator to facilitate stripping, gray cross-linked polyethylene (XLP) insulation
APPLICATIONS:
For use in wet or dry locations for switchboards, distribution boards, panelboards and control apparatus
NOTE:
VW-1 rated on request
Not SIS
*
Other colors available on request
OLYMPIC
NO.
7070
*
7071
*
7072
7073
7074
7075
UL 3196
7075/6
7075/4
*
7075/2
SWITCHBOARD
WIRE
125°C-600 VOLTSUL 3173, SIS
CONDUCTOR NOM.
AWG STRANDING
18
16
14
12
10
8
6
4
2
16 x 30
26 x 30
41 x 30
65 x 30
104 x 30
133 x 29
133/27
133/25
133/23
INSULATION
THICKNESS
.030”
.030”
.030”
.030”
.030”
.045”
.060”
.060”
.060”
O.D.
.113”
.125”
.143”
.165”
.195”
.270”
.340”
.379”
.470”
21
173010_olympic_catalog_2017_v9.indd 21 6/26/17 10:31 AM
Loading...