Oki HCT-1000 User Manual

HCT-1000
HCT-1000
HCT-1000
Betriebsanleitung
HCT-1000
Manuel d’utilisation
HCT-1000
Manuale dell'utente
HCT-1000
Guía del usuario
1
INTRODUCTION
The HCT-1000 is a hand-held convection rework tool. It features digital controls, multiple modes of operation, internal or external feedback control and integrated vacuum pick-up for component placement and removal. Additionally, this unit may be connected to the PCT-1000 as part of the Modular Rework System.
CONTENTS
1. Safety & Warranty 1
2. Specifications 2
3. Unit identification 3
4. Setup and unit operation 4, 5 & 6
5. Additional Features 6
6. Nozzle Information 7
7. Operation 8
8. Troubleshooting 8
9. Maintenance 9
SAFETY Intended Use:
WARNING: Use of this equipment in ways other than those described in this User Guide
may result in injury to persons or damage to property. Use this equipment only as described in this User Guide. OK International cannot be responsible for injuries or damages resulting from unintended applications of its equipment. Unintended uses may result from taking the following actions:
• Making changes to equipment that has not been recommended in the User Guide
• Using incompatible or damaged replacement parts
• Using unapproved accessories or auxiliary equipment
Safety Precautions:
• Do not operate this unit in excess of maximum ratings/settings
• Always wear appropriate personal protective clothing or apparel
• This equipment is for indoor use only
Warranty
OK International warrants the HCT-1000 hand-held convection rework tool power supply against any defects in materials or workmanship for one (1) year from the date of purchase by the original owner.
OK International warrants the HCT-1000 hand-held convection rework tool hand-piece (HCT-HV1) against any defects in materials or workmanship for one (1) year from the date of purchase by the original owner.
OK International warrants the HCT-1000 heater assembly (HCT-HTRASSY) against any defects in materials or workmanship for ninety (90) days from the date of purchase by the original owner.
This Warranty excludes normal maintenance and shall not apply to any opened, misused, abused, altered or damaged items. If the product should become defective within the warranty period, OK International will repair or replace it free of charge at its sole option. The replacement item(s) will be shipped, freight prepaid, to the original purchaser. The warranty period will start from the date of purchase. If the date of purchase cannot be substantiated the date of manufacture will be used as the start of the warranty period
2
2. HCT-1000 SPECIFICATIONS
Size
9” x 7” x 6” (229 mm x 178 mm x 152 mm) Weight
12lbs Input Voltage
100-240 VAC, 50/60 Hz Rated Power
600W Pollution Degree Category
II Storage Temperature
-10°C to 60°C (14°F to 140°F) Operating Temperature
0°C to 50°C (32°F to 122°F) Air Pump Type
Diaphragm Air Flow
5-25 l/min Vacuum Pump
15” Hg (381 mm Hg)
Control Temperature
Surface Resistivity
107Ω to 1011Ω
Noise Level
< 55 dB
Certifications
TUV
Max. Relative Humidity
80% for temperature up to 31°C (87.8°F) Decreasing linearly to 50% relative humidity at 40°C (104°F)
System Modes
HCT, MRS Operational Modes
Setup, Run, Manual, Active Setup Memory Locations
50 Display
LCD 20 X 4 display segments
Description HCT-PS1000
HCT-1000 Power Supply HCT-HV1
Hand-piece with integral vacuum, cord and connector HCT-FS2
Footswitch, Dual, HCT-1000 HCT-NC
Nozzle Carrier, HCT-1000 nozzles HCTA-TH1
Hand-piece tool Holder HNA-1
Nozzle Adapter HCTA-NW1
Nozzle Wrench HCTA-VCT1
Vacuum Cup Tool
Accessories HCTA-VC24
Vacuum Cup, 3/32” (2.38mm) HCTA-VC50
Vacuum Cup, 3/16” (5.00mm) HCTA-VC64
Vacuum Cup, ¼” (6.4mm) HCTA-VC80
Vacuum Cup, 5/16” (8mm) HCTA-VC11
Vacuum Cup, 7/16” (11mm) HCTA-ASC
Anti-seize Compound AC-TCK-24-36
Thermocouple HCTA-CC
Communications Cable HCT-HTRASSY
Heater Assembly
3
3. Unit Identification Figure 1 HCT-PS1000 Power Supply
Figure 3: Run Mode, Before Profile Start
Figure 4: Run Mode, After Profile Start, MRS Mode
Z 1 : 1 5 0
°c 6 5 s P
0
6
Z 2 : 2 0 0
°c 5 5 s T C : I N T
Z 3 : 2 5 0
°c 4 5 s
Z 4 : 3 0 0
°c 3 0 s
Z 1 :
5 5 s P 0 6
T - S E T
: 1 5 0
°c T C : I N
T
T
- H t r : 1 3 6
°c 1 2 5 °c R E M O V E
() Enter/Profile Select
Power On/Off
Timer/Temperature Adjust Down
Timer/Temperature Adjust Up
and Profile start/abort
Thermocouple (TC1)
Thermocouple (TC2)
Hand-piece Connector
Power Connector
Footswitch Connector
Communications Connector
Figure 2 Back Panel Detail
T
C
1:
Active Zone
Zone Set Point
Actual Heater Reading
Temperature Monitor
Thermocouple Control
Selected Profile
Place/Remove Option
(Only Available in MRS Mode)
Zone Target Temperature
Profile Parameters
4
Figure 5 HCT-HV1 Hand-piece Assembly
4. Setup and unit operation
1. Basic unit setup
1. Connect the hand-piece assembly, HCT-HV1, to the power supply.
2. Plug the power cord into the power connector (Figure 2). Plug the power cord into a grounded wall socket of the rated input line voltage.
3. Connect the dual footswitch, HCT-FS2, to the unit (Figure 2).
4. Turn On the unit by pressing the Power button momentarily.
5. To Abort a Profile (to the Cool-Down zone*) press and hold the (red) on the footswitch or (red) on the hand-piece down while in Run Mode.
6. *Note: Depressing the (red) on the footswitch or (red) on the hand-piece a second time will decrease the cool down time to a minimum of 60 seconds.
7. Turn Off the unit by pressing the Power button momentarily. Note ~ you must be out of set-up mode in order to do this. I.e. no flashing numbers on the display.
2. System Mode Selection
The HCT-1000 has two system modes of operation.
The first mode is HCT. In this mode, the HCT-1000 is used as a standalone
handheld convection rework tool.
The second mode is MRS. In this mode, the HCT-1000 is used as part of a Modular Rework System. The unit is connected via cable to a PCT-1000 and
may be used with the ATH-1000 Adjustable Tool Holder. In this mode the HCT-1000 provides timing control for both units and the ATH-1000 allows repeatable place and remove operations.
Plug the Communications Cable into the Communication Connector (Figure 2 above) on the HCT-1000 and the PCT-1000. When connected in MRS mode the time setting on the PCT-1000 will display “- -“.
Vacuum Pick-up Tube
(red) Profile Start/Abort
(blue) Vacuum Activation
Vacuum Pick-up Tube Adjustment
Heater Assembly
Figure 6 HCTA-TH1
Figure 7
5
Selection of the System mode is made in Setup mode, refer to section 3.1. Additional operational options are available, refer to section 3.5.
3. Operational Mode Selection
The HCT-1000 has four operational modes. The operational modes are Setup, Run, Manual and Active Setup. The Setup mode is for modifying system or profile parameters. The Run mode is for operating the unit with a profile that uses four zones of heating. The Manual mode is for operating the unit with a single zone of heat and no time limit. The Active Setup mode allows for the changing of parameters within a running profile.
1. Setup Mode
1. Press the Mode button () once to start “P:” flashing
2. Use the / buttons to scroll through the profiles
3. Press () to select the desired profile
4. Press and hold () for 3 seconds to activate program mode (first temperature in zone 1 will flash).
5. Run Mode setup; proceed to step 3.1.6.1; Manual Mode setup
proceed to step 3.1.7.1.
6. Run Mode Setup
1. Use the / buttons to change the temperature to the desired value. (Note: continually pressing either the or buttons for 5 seconds will change the count up/down in an accelerated mode)
2. When the value is set, press () to move to the next parameter.
3. Repeat steps 3.1.6.1 & 3.1.6.2 until profile is programmed. Note: In the Cool-Down Zone you can only modify the Time parameter
4. Proceed to step 3.1.8.
7. Manual Mode Setup
1. Use the / buttons to change the temperature to the desired value. (Note: continually pressing either the or buttons for 5 seconds will change the count up/down in an
accelerated mode)
2. Set the Time for Zone 1 to a value greater than 300 seconds. The display will now show the word MANUAL and Z2, Z3, Z4 will no longer be shown on the display. Note: Manual mode profiles do not have a time requirement and once activated will run until the profile is stopped.
3. Once required changes have been made, press and hold () for 3 seconds until the LCD tops flashing, to set the profile to memory and exit setup mode.
8. Press () to move to the next parameter. This is the HCT or MRS option. Use or to switch between HCT or MRS or press () to skip
9. Press () to move to the next parameter. This is the Internal or External TC option. Use or to switch between Int or Ext or press () to skip. Note: When EXT is selected, TC1 becomes the master thermocouple and provides feedback to the power supply.
10. Press () to move to the next parameter. This is the Airflow option (AF). Use to increase or to decrease the airflow. The range is adjustable from 1-10. Note the Air Pump will turn on will adjusting the Airflow. Press () to skip.
11. Once required changes have been made, press and hold () for 3 seconds until the LCD stops flashing, to set the profile to memory and exit setup mode. (see Figure 1 above)
6
2. Run & Manual Mode
1. Turn on the unit by pressing the Power button.
2. HCT start-up message and Software Rev # are momentarily displayed
before displaying last-used profile settings. Note: The unit may display MRS-1000 if that was the last operational state.
3. IMPORTANT ~ If “TC: Ext” is displayed on the panel (see Figure 4
above) ensure that the external thermocouple is suitably positioned in the heat path. Neglecting to do this could result in premature heater failure
4. Select the desired profile.
5. When the chosen profile is shown, press () to select the desired profile
6. To start the profile, depress the (red) on the footswitch or (red) on
the hand-piece once
7. As the profile runs you will see the current zone, time remaining, heater
value and temperature set point. Manual mode profiles will display “Manual” and will not display time remaining.
8. To quit the profile, simply depress the (red) on the footswitch or
(red) on the hand-piece continually for 3 seconds. The profile will skip to the Cool-Down Zone. Note: Repeating step 8 turns off the Cool-Down Zone after a minimum of 60 seconds of cooling.
3. Active Setup Mode
1. Select Profile to be modified as per steps 1 3 above
2. To activate Active Setup Mode press () for 3 seconds then depress the
(red) on the footswitch or (red) button on the hand-piece once the temperature in Z1 has started to flash
3. Profile will start to run and ‘SETUP’ will be displayed on LCD
4. To modify the current zone set-temperature use the / buttons
5. To increase the time of the current zone press and hold the () button as
the zone ends. Instead of stepping onto the next zone the current zone time-setting will increment the original setting for as long as you keep the () button depressed. Releasing the button will allow the profile to progress onto the next Zone.*
6. To decrease the zone time, depress the (red) on the footswitch or
(red) button on the hand-piece at the desired time. This will set the time to memory and advance the profile into the next zone.* Note: Steps 3.4.5 & 3.4.6 can be carried out simultaneously
7. Once required changes have been made, allow the profile to finish. Press
and hold (), until the LCD tops flashing, to set the profile to memory and exit setup mode
8. *Note: feature not available in Cool-Down Zone
5. Additional Features
1. Integrated Vacuum Pick-up
The vacuum pick-up tube has 1.0” (25.4 mm) of travel and is spring loaded to prevent damage to components during attachment. Use an appropriate sized vacuum cup to make a seal on the component.
2. HCT System Mode
1. Press the (blue) on the footswitch or (blue) on the hand-
piece once to activate the vacuum pump and again to deactivate.
3. MRS System Mode – Place or Remove selection
7
1. To toggle between Place and Remove; press and hold the (blue) on the footswitch or (blue) button on the hand-piece for 3 seconds.
4. MRS System Mode - Place
1. Press the (blue) on the footswitch or (blue) button on the hand-piece once to activate the vacuum pump and again to deactivate.
5. MRS System Mode - Remove
1. The integrated vacuum pick-up will automatically activate the vacuum and retract the vacuum pick-up tube at the completion of Zone 4 (Z4) in Run mode. The vacuum will be active for the duration of the ZC (Cool-Down Zone).
6. MRS System Mode – Positive Vacuum Indicator
1. VAC will be displayed when the vacuum has been activated while in Setup or Run Mode (Figure 4). VAC will blink when a positive seal has been achieved with the component.
7. External Thermocouple Control
1. When using the HCT-1000 with the external thermocouple (EXT see Figure 4 above), TC1 is used to provide external feedback control. Ensure that the thermocouple is placed in the heat path. Failure to do so may result in an error or damage to the component. TC2 can be used for temperature monitoring (refer to
1.5.7)
2. When using the HCT-1000 with external thermocouples in MRS mode, TC1 on the HCT-1000 becomes the master thermocouple and is used to provide external feedback for the entire system. TC2 on the HCT-1000 and TC1 & TC2 on the PCT-1000 can be used for temperature monitoring only (refer to 1.9 and PCT-1000 User Guide 7000-2420, section 4.4).
8. Temperature Monitoring
1. While using the HCT-1000 with the internal thermocouple (INT see Figure. 3 above), TC1 and TC2, the external thermocouples, may be used to monitor temperature.
2. Attach a thermocouple to TC1 and/or TC2 and attach to the area to be monitored. When attached, the appropriate thermocouple will be displayed (see Figure 4 above).
6. Nozzle Attachment
1. Secure the Nozzle Adapter (HNA-1) to Heater Assembly
1. Loosen clamp screw counterclockwise (Figure 6, 1)
2. Close the clamp (Figure 6, 2).
3. Slide the Nozzle Adapter up the heater assembly (Figure 5) until it stops.
4. Tighten the clamp screw clockwise (Figure 6,
1) for firm fit of the adapter to the heater assembly. Once adjusted, removing the adapter is done by opening the clamp and sliding the adapter off the heater assembly.
2. Nozzle to Nozzle Adapter
1. Select the proper nozzle for the application.
Figure 6: Nozzle Adapter (HNA-1)
1
2
3
8
2. To attach; screw the nozzle to the nozzle adapter (Figure 6, 3); tighten clockwise with Nozzle Wrench.
3. To remove; unscrew the nozzle from the adapter (Figure 6, 3); loosen counterclockwise with Nozzle Wrench.
3. Nozzle Selection
1. Select the appropriate sized nozzle for the application. This is only a sample of the available nozzles. Please refer to the HCT-1000 Nozzle Selection Guide or visit our website www.okinternational.com for the complete selection.
7. Operation
1. De-Soldering Components using convection heat
1. Select the proper nozzle, and secure it to the adapter.
2. Set the desired profile.
3. Move the nozzle close to the component leads; maintain 3-5 mm distance. Use the hot air to melt the solder
4. When solder is molten, use the integrated vacuum, tweezers or other suitable tool to remove the component from the circuit board
2. Soldering Components using convection heat
1. Choose the proper nozzle, secure it to the adapter.
2. Apply the right amount of solder to the circuit board; position the component on the circuit board.
3. Set the desired profile.
4. Move the nozzle closer to the component leads, blow hot air onto the leads and melt the solder.
8. Troubleshooting
1. Unit does not power ON
Check the power cord
Check to see that you have mains voltage
2. OH displayed on the LED screen
Unit has exceeded the internal safety cut-off
Allow unit to cool
Check placement of thermocouple (if used)
Reset the unit by cycling the power
3. TCFAULT displayed on LED screen
Check location of thermocouple
Ensure the thermocouple is firmly inserted into the correct TC
connector
Replace thermocouple if problem persists
4. Flashing zone and temperature parameters while in Run Mode
Indicates the unit cannot meet the programmed time and temperature as set
9. Maintenance
The Hand-piece (HCT-HV1) will be part of OK International’s Service Exchange Program or the heater assembly (HCT-HTRASSY) can be purchased separately as a replacement part.
HN-J0005,
5.0MM
HN-B1010
10MM x 10MM
HN-1818
18MM x 18MM
HN-B4040,
40MM x 40MM
9
Please visit OK International’s web page (www.okinternational.com) where you will find additional information on systems, accessories, technical notes, and more.
1
EINFÜHRUNG
Das HCT-1000 ist ein handgehaltenes Konvektionsnacharbeitswerkzeug. Es enthält digitale Bedienelemente, mehrere Betriebsarten, internen oder externen Regelungsmechanismus und integrierte Vakuumaufnahme zur Komponentenplatzierung und -entfernung. Des Weiteren kann dieses Gerät innerhalb des modularen Nacharbeitsystems (Modular Rework System, MRS) an das PCT-1000 angeschlossen werden.
INHALT
1. Sicherheit und Garantie 1
2. Technische Daten 2
3. Geräte-ID 3
4. Einrichtung und Gerätebetrieb 4, 5 & 6
5. Zusätzliche Merkmale 7
6. Düseninformationen 8
7. Betrieb 8
8. Problembehebung 9
9. Pflege 9
SICHERHEIT Verwendungszweck:
WARNUNG: Wenn das Gerät anders als in dieser Betriebsanleitung beschrieben
verwendet wird, besteht die Gefahr von Personen- und Sachschäden. Verwenden Sie dieses Gerät nur im Einklang mit der Beschreibung in dieser Betriebsanleitung. OK International haftet nicht für Verletzungen oder Schäden, die aufgrund einer zweckfremden Verwendung dieses Gerätes entstehen. Eine zweckfremde Verwendung schließt auch Folgendes ein:
• Veränderungen am Gerät, die in der Betriebsanleitung nicht empfohlen werden
• Verwendung von nicht kompatiblen oder beschädigten Ersatzteilen
• Verwendung von nicht zugelassenen Zubehörteilen oder Hilfsgeräten
Vorsichtsmaßnahmen:
• Dieses Gerät darf nicht außerhalb der maximalen Nennwerte/Einstellungen betrieben werden
• Immer geeignete Schutzkleidung tragen
• Dieses Gerät ist nur zur Verwendung in Gebäuden bestimmt
Garantie
OK International gewährt für das Netzteil des handgehaltenen HCT-1000­Konvektionsnacharbeitswerkzeugs hinsichtlich Material- oder Verarbeitungsmängel eine Garantie von einem (1) Jahr, gerechnet ab Datum des Kaufs durch den ursprünglichen Eigentümer.
OK International gewährt für den Lötgriffel (HCT-HV1) des handgehaltenen HCT-1000­Konvektionsnacharbeitswerkzeugs hinsichtlich Material- oder Verarbeitungsmängel eine Garantie von einem (1) Jahr, gerechnet ab Datum des Kaufs durch den ursprünglichen Eigentümer.
OK International gewährt für die Heizer-Baugruppe (HCT-HTRASSY) des HCT-1000 hinsichtlich Material- oder Verarbeitungsmängel eine Garantie von neunzig (90) Tagen, gerechnet ab Datum des Kaufs durch den ursprünglichen Eigentümer.
Diese Garantie schließt die normale Wartung aus und gilt nicht für geöffnete, unsachgemäß oder zweckentfremdet verwendete, modifizierte oder beschädigte Geräte. Wenn innerhalb des Garantiezeitraums Mängel am Produkt auftreten, repariert oder ersetzt OK International es kostenlos nach eigenem Ermessen. Reparierte bzw. ausgetauschte Teile werden an den Originalkäufer geliefert, die Versandkosten trägt OK International. Der Garantiezeitraum beginnt ab Zeitpunkt des Kaufs. Wenn das Kaufdatum nicht nachgewiesen werden kann, gilt das Herstellungsdatum als Beginn des Garantiezeitraums.
2
2. TECHNISCHE DATEN ZUM HCT-1000
Maße
229 mm x 178 mm x 152 mm
Gewicht
5440 g
Eingangsspannung
100 V AC, 50/60 Hz
Nennleistung
600 W
Verschmutzungsgrad­Kategorie
II
Temperaturbereich für die Aufbewahrung
-10 °C bis 60 °C
Umgebungstemperatur bei Betrieb
0 °C bis 50 °C
Luftpumpentyp
Membranmechanismus
Luftstrom
5 – 20 l/min
Vakuumpumpe
381 mm Hg
Regeltemperatur
Spezifischer Oberflächenwiderstand
107Ω bis 10
11
Ω
Geräuschpegel
< 55 dB
Zulassungen
TUV
Max. relative Luftfeuchtigkeit
80 % bei Temperaturen bis zu 31 °C mit linearer Reduzierung der relativen Luftfeuchtigkeit bis zu 50 % bei 40 °C
Systemmodi
HCT, MRS
Betriebsarten
Setup, Betrieb, Manuell, Aktives Setup
Speicherplätze
50
Anzeige
LCD, mit vier 20 Zeichen langen Zeilen Beschreibung
HCT-PS1000
HCT-1000-Netzteil
HCT-HV1
Lötgriffel mit Integralvakuum, Kabel und Anschluss
HCT-FS2
Fußschalter, Dual, HCT-1000
HCT-NC
Düsenhalter, HCT-1000-Düsen
HCTA-TH1
Löffelgriffelhalter
HNA-1
Düsenadapter
HCTA-NW1
Düsenschraubenschlüssel
HCTA-VCT1
Saugnapfwerkzeug
Zubehör HCTA-VC24
Saugnapf, 2,38 mm
HCTA-VC50
Saugnapf, 5,00 mm
HCTA-VC64
Saugnapf, 6,4 mm
HCTA-VC80
Saugnapf, 8 mm
HCTA-VC11
Saugnapf, 11 mm
HCTA-ASC
Antiblock-Paste
AC-TCK-24-36
Thermoelement
HCTA-CC
Kommunikationskabel
HCT-HTRASSY
Heizer-Baugruppe
3
3. Geräte-ID Abbildung 1 HCT-PS1000-Netzteil
Abbildung 3: Betriebsmodus, vor Profilstart
Abbildung 4: Betriebsmodus, nach Profilstart, MRS-Modus
Z 1 : 1 5 0
°c 6 5 s P
0
6
Z 2 : 2 0 0
°c 5 5 s T C : I N T
Z 3 : 2 5 0
°c 4 5 s
Z 4 : 3 0 0
°c 3 0 s
Z 1 :
5 5 s P 0 6
T - S E T
: 1 5 0
°c T C : I N
T
T
- H t r : 1 3 6
°c 1 2 5 °c R E M O V E
T
C
1:
Zonensollwert
Bisheriger Heizmesswert
Temperaturüberwachung
Ausgewähltes Profil
Zonenzieltemperatur
Strom ein/aus
Zeitschalter/Temperaturreduzierung
(↵) Eingabe/Profilauswahl
Zeitschalter/Temperaturerhöhung
und Profil starten/abbrechen
Thermoelement (TC1)
Thermoelement (TC2)
Lötgriffelanschluss
Stromanschluss Fußschalteranschluss
Kommunikationsanschluss
Abbildung 2 Rückplattendetail
Aktive Zone
Thermoelementsteuerung
Profilparameter
Platzieren/Entfernen-Option
(Nur im MRS-Modus verfügbar)
4
Abbildung 5 HCT-HV1 Lötgriffelbaugruppe
4. Setup und Gerätebetrieb
1. Grundlegende Geräteeinrichtung
1. Schließen Sie die Lötgriffelbaugruppe, HCT-HV1, an das Netzteil an.
2. Stecken Sie das Netzkabel in den Netzanschluss (Abbildung 2). Stecken Sie das Netzkabel in eine Schukosteckdose mit der angegebenen Netzspannung ein.
3. Schließen Sie den Dual-Fußschalter, HCT-FS2, an das Gerät an (Abbildung 2).
4. Schalten Sie das Gerät durch kurzes Drücken des Netzschalters ein.
5. Zum Abbrechen eines Profils (sofortiger Wechsel in die Abkühlzone*) drücken und halten Sie im Betriebsmodus (rot) am Fußschalter oder (rot) am Lötgriffel gedrückt.
6. *Hinweis: Durch erneutes Drücken auf (rot) am Fußschalter oder (rot) am Lötgriffel wird die Abkühlzeit auf ein Minimum von 60 Sekunden reduziert.
7. Schalten Sie das Gerät durch kurzes Drücken des Netzschalters aus. Hinweis ~ Das Gerät darf sich hierbei nicht im Setup-Modus befinden, d. h. auf der Anzeige dürfen keine blinkenden Zahlen vorhanden sein.
2. Auswahl des Systemmodus
Das HCT-1000 verfügt über zwei Systemmodi.
Die erste Betriebsart ist HCT. In diesem Modus wird das HCT-1000 als
unabhängiges handgehaltenes Konvektionsnacharbeitswerkzeug verwendet.
Die zweite Betriebsart ist MRS. In diesem Modus wird das HCT-1000 als Teil eines modularen Nacharbeitsystems (Modular Rework System, MRS) verwendet. Das Gerät wird über ein Kabel mit einem PCT-1000 verbunden und kann mit dem einstellbaren ATH-1000-Werkzeughalter verwendet werden. In diesem Modus liefert das HCT-1000 Timing-Steuerung für beide Geräte und das ATH-1000 erlaubt wiederholbare Vorgänge zum Platzieren und Entfernen.
Vakuumaufnahmeschlauch
(rot) Profilstart/-abbruch
(blau) Vakuumaktivierung
Vakuumaufnahmeschlauch­Einstellung
Heizer-Baugruppe
Abbildung 6 HCTA-TH1
Abbildung 7
5
Stecken Sie das Kommunikationskabel in den Kommunikationsanschluss (Abbildung 2 oben) am HCT-1000 und PCT-1000. Wenn der Anschluss im MRS­Modus erfolgt, erscheint die Uhrzeiteinstellung auf dem PCT-1000 als „- -”.
Die Auswahl des Systemmodus erfolgt im Einrichtmodus (siehe Abschnitt
3.1). Weitere Betriebsarten sind verfügbar (siehe Abschnitt 3.5).
3. Auswahl des Betriebsmodus
Das HCT-1000 verfügt über vier Betriebsarten. Die Betriebsarten lauten Setup, Betrieb, Manuell, Aktives Setup. Der Einrichtmodus ermöglicht das Modifizieren von System- oder Profilparametern. Der Betriebsmodus ermöglicht den Betrieb des Geräts mit einem Profil, das vier Heizzonen verwendet. Der manuelle Modus ermöglicht den Betrieb des Geräts mit einer einzelnen Heizzone ohne Zeitlimit. Der aktive Einrichtmodus ermöglicht das Ändern von Parametern innerhalb eines laufenden Profils.
1. Einrichtmodus
1. Drücken Sie einmal die Modus-Taste (), worauf „P:“ zu blinken beginnt.
2. Verwenden Sie die Tasten / , um durch die Profile zu blättern.
3. Drücken Sie () , um das gewünschte Profil auszuwählen.
4. Halten Sie die Eingabetaste () 3 Sekunden lang gedrückt, um den Programmmodus zu aktivieren (die erste Temperatur in Zone 1 beginnt zu blinken).
5. Einrichten des Betriebsmodus; weiter mit Schritt 3.1.6.1;
Einrichten des manuellen Modus, weiter mit Schritt 3.1.7.1.
6. Einrichten des Betriebsmodus
1. Verwenden Sie die Tasten / , um den gewünschten Wert für die Temperatur einzustellen. (Hinweis: Durch 5 Sekunden langes Gedrückthalten der Taste oder wird eine beschleunigte Erhöhung bzw. Reduzierung des angezeigten Wertes bewirkt.)
2. Nachdem der Wert eingestellt wurde, drücken Sie (), um zum nächsten Parameter zu gelangen.
3. Wiederholen Sie die Schritte 3.1.6.1 und 3.1.6.2, bis das Profil programmiert ist. Hinweis: In der Abkühlzone kann nur der Zeitparameter geändert werden.
4. Weiter mit Schritt 3.1.8.
7. Einrichten des manuellen Modus
1. Verwenden Sie die Tasten / , um den gewünschten Wert für die Temperatur einzustellen. (Hinweis: Durch 5 Sekunden langes Gedrückthalten der Taste oder wird eine beschleunigte Erhöhung bzw. Reduzierung des angezeigten Wertes bewirkt.)
2. Stellen Sie die Zeit für Zone 1 auf einen Wert von mehr als 300 Sekunden ein. Auf der Anzeige wird nun das Wort MANUAL eingeblendet und Z2, Z3, Z4 sind nicht mehr zu sehen. Hinweis: Profile im manuellen Modus enthalten keine Zeitanforderungen und laufen nach der Aktivierung so lange, bis das Profil gestoppt wird.
3. Nachdem alle notwendigen Änderungen eingegeben wurden, halten Sie die Taste () 3 Sekunden lang gedrückt, bis die LCD­Anzeige aufhört zu blinken. Dadurch wird das Profil gespeichert und der Setup-Modus beendet.
8. Drücken Sie () , um zum nächsten Parameter zu gelangen. Dies ist die HCT- oder MRS-Option. Drücken Sie oder , um zwischen HCT und MRS zu wechseln, oder drücken Sie (), um diesen Parameter zu überspringen.
Loading...
+ 32 hidden pages