Ohaus GraviTek Titration Scale User Manual

GraviTek™ Titration Scale
Instruction Manual
Compliance
Compliance to the following standards is indicated by the corresponding mark on the product
This product conforms to the EMC directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. The complete declaration of Conformity is available from you local dealer
Disposal
I
n conformance with the European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements.
Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment.
If you have any questions, please contact the responsible authority or the distributor from which you purchased this device.
Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related.
Thank you for your contribution to environmental protection.
FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help
Industry Canada Note This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada
ii
.
GraviTek™ Titration Scale
EN-1
1. INTRODUCTION
This manual contains installation, operation and maintenance instructions for the GraviTek scale.
TM
Titration Scale. Please read the manual completely before using the
1.1 Safety Precautions
Please follow these safety precautions:
Verify that the Power Adapter input voltage matches the local power supply voltage.
Use the scale only in dry locations.
Do not operate the scale in hostile environments.
Do not drop heavy loads on the pan.
Do not place the scale upside down on the pan.
Service should be performed only by authori zed personnel.
1.2. LCD Display & Controls
LCD Display Indicators:
Battery Power Indicator
* Stability Indicator Figure 1-1. LCD Display &
Controls
g Gram Indicator
88 Test Type Number
g
PPM Indicator
ppm
TABLE 1-1, CONTROL FUNCTIONS
Button Name Function
Primary function (Short Press) – If scale is Off, turn On.
On-Zero
Off Yes
If scale is on, perform Zero/Tare function
Secondary function (Long Press) – Turn scale Off
Menu function – (Yes) This key is used to accept the
currently displayed setting
EN-2
GraviTek™ Titration Scale
Button Name Function
Primary function (Short Press) – When in the Test Mode
Accept
Menu
Accepts the displayed value for input.
Secondary function (Long Press) – Enters the User
Menu.
Primary function (Short Press) – Send the current
Print
Cal
display value to serial port if installed
Secondary function (Long Press) – Starts a Span
calibration
Primary function (Short Press)– Advances to next
available Test Type or Weighing Mode
Mode
Test
No
Secondary function (Long Press) – Scrolls through the
available Test Types and Weighing Modes.
Menu function – (No) This key is used to reject the
displayed setting and advance to next available setting
2. INSTALLATION
2.1 Package Contents
• Scale
• Pan
• Draft Shield
• Calibration Weight
2.2. Location
Use the scale on a firm, steady surface. Avoid locations with excessive air currents, vibrations, heat sources, or rapid temperature changes. Adjust the leveling feet so the bubble is centered within the smaller circle. See Figure 2.1.
• Power Adapter
• 4 Alkaline Batteries
• USB Module
• USB Driver Mini-CD
Level Bubble
Figure 2-1, Leveling Adjustments
GraviTek™ Titration Scale
EN-3
2.3. Transportation Lock, Calibration Lock & Pan Installation
Before using the scale the Transportation Lock must be released. At the bottom of the scale slide the locking pin to the position. See Figures 2-2.
If the scale is to be calibrated by the user ensure that the Calibration Lock is set to position. See Figure 2-3.
Install the metal pan over the plastic sub-platform.
Figure 2-2. Release Transportation Lock
Figure 2-3. Release Calibration Lock
2.4 Connect Power
A Power Adapter may be used to power the scale. Connect the Power Adapter to an AC power outlet (see Figure 2-4) and insert the power plug at the back of the scale (see Figure 2-5)
For use only with UL or CSA Certified (or equivalent approved) power adapter, which is a Class 2 or a Limited Power Source device.
Figures 2-4, Power Adapter Figure 2-5, Power Plug
EN-4
GraviTek™ Titration Scale
2.5 Battery Installation and Use
The scale may also be powered by batteries. Remove the battery cover and install four alkaline AA (LR6) type batteries. Refer to Figure 2.6 to properly install the batteries. Under battery power a battery symbol is shown on the left side of the display. The Auto-Off setting is useful for conserving battery power, see section 4.2.1.
Figures 2-6, Battery Installation
2.6 Initial Calibration
Power on the scale by pressing On-Zero. Allow at least one minute for the scale to stabilize before calibrating. Press and hold the Print/Cal button until [CAL] is displayed. The display flashes [-C-] while zero reading is taken. The display flashes the required span mass. Place the indicated calibration mass on the pan and press Yes. The display flashes [-C-]. When calibration is complete, [DonE] is displayed.
Note: Calibration is also available in the Setup menu, see section 4.2.1.