Oase BioMaster 600 User Manual

BioMaster 250/350/600 BioMaster Thermo 250/350/600
5
BMR0003
B
BMR0004
A
2 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0
5
D
BMR0021
BMR0022
C
3
5
BMR0008
BMR0009
BMR0010
BMR0011
E
G
F
H
4 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0
5
BMR0014
BMR0015
BMR0006
BMR0023
I
J
K
L
5
5
M
FSt0015
N
BMR0026
6 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0
5
O
BMR0005
P
BMR0007
7
5
BMR0012
BMR0013
BMR0016
BMR0017
Q
R
S
8 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0
T
5
BMR0024
U
9
5
BMR0018
BMR0019
X
BMR0020
V
W
10 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0

- DE -

Original Gebrauchsanleitung
WARNUNG
Dieses Gerät kann von Kindern ab 8 Jahren und darüber sowie von Personen mit verringerten physischen, sensorischen oder mentalen Fähigkeiten oder Mangel an Erfahrung und Wis­sen benutzt werden, wenn sie beaufsichtigt oder bezüglich des sicheren Gebrauchs des Gerätes unterwiesen wurden und die daraus resultierenden Gefahren verstehen.
Kinder dürfen nicht mit dem Gerät spielen.
Reinigung und Benutzerwar- tung dürfen nicht von Kindern ohne Beaufsichtigung durch­geführt werden.
Alle Geräte im Aquarium aus- schalten oder den Netzstecker ziehen, bevor Sie in das Was­ser greifen.
Gerät nicht verwenden, wenn elektrische Leitungen oder Ge­häuse beschädigt sind.
Gerät nur anschließen, wenn die elektrischen Daten von Ge­rät und Stromversorgung übereinstimmen. Die Geräte­daten befinden sich auf dem Typenschild am Gerät, auf der Verpackung oder in dieser An­leitung.
Vor Arbeiten am Gerät Netz- stecker ziehen.
- DE -
SICHERHEITSHINWEISE
Bei defektem Gehäuse darf das Gerät nicht betrie- ben werden.
Bei defekten elektrischen Leitungen darf das Gerät nicht betrieben werden.
Gerät nicht an der elektrischen Leitung tragen oder ziehen.
Leitungen geschützt vor Beschädigungen verlegen und darauf achten, dass niemand darüber fallen kann.
Gehäuse des Gerätes oder zugehöriger Teile nur öff- nen, wenn in dieser Anleitung ausdrücklich dazu aufgefordert wird.
Nur die Arbeiten am Gerät durchführen, die in die- ser Anleitung beschrieben sind. Wenn sich Pro­bleme nicht beheben lassen, eine autorisierte Kun­dendienststelle oder im Zweifelsfall den Hersteller kontaktieren.
Nur Original-Ersatzteile und –Zubehör für das Gerät verwenden.
Niemals technische Änderungen am Gerät vorneh- men.
• Steckerverbindungen vor Feuchtigkeit schützen.
Gerät nur an einer vorschriftsmäßig installierten
Steckdose anschließen.

Warnhinweise in dieser Anleitung

Die Warnhinweise in dieser Anleitung sind durch Si­gnalworte klassifiziert, die das Ausmaß der Gefähr­dung anzeigen.
WARNUNG
Bezeichnet eine möglicherweise gefährliche Situation.
Bei Nichtbeachtung kann Tod oder schwerste Verletzung die Folge sein.
HINWEIS Informationen, die zum besseren Verständnis oder der Vorbeugung möglicher Sach- oder Umweltschäden dienen.

Verweise in dieser Anleitung

5 A Verweis auf eine Abbildung, z. B. Abbildung A.
Verweis auf ein anderes Kapitel.
11
- DE -
5 A
BioMaster Thermo
1
BioMaster Thermo 250: HeatUp 150 BioMaster Thermo 350: HeatUp 200 BioMaster Thermo 600: HeatUp 300
2
Gebrauchsanleitung HeatUp 25/50/75/100/ 150/200/250/300
BioMaster, BioMaster The rmo
3
Gebrauchsanleitung BioMaster 250/3 BioMaster Thermo 250/350/600
4
Durchlassring für Montage HeatUp
5
Blindstopfen
6
Griff, bei eingeklapptem Griff sind zwei Spannver­schlüsse (10), verriegelt
7
Gerätekopf
8
Vorfilter mit Ansaugknopf
9
Anschlusseinheit mit Schlauchtüllen Ausgang und Eingang
10
Spannverschluss
11
Behälter, gefüllt mit Filtermaterial
12
Gummifüße
5 B
Saugeinheit, Ausströmeinheit
Anzahl
1
Ansaugrohr
1 2 Schlauch
1 3 Ausströmrohr
2
4
Saugnapf
5
5
Schlauchadapter, regelbar
2 6 Adapter Ansaugrohr
1
7
Saugkorb
1
8
Klemme
5 9 Winkelstück
1
10
Überwurfmutter
4
11
Schlauchstück als Verbindungsstück für Ausströmrohre (3)
1
12
Wasserverteiler
1
13
Verschlusskappe
1

PRODUKTBESCHREIBUNG

Lieferumfang

50/600,
Für das Gerät gelten folgende Einschränkungen:
Nur in Räumen und für private aquaristische Zwecke verwenden.
Betrieb nur mit Wasser bei einer Wassertemperatur von +4 °C … +35 °C.

Funktionsbeschreibung

Angesaugt von einer Pumpe im Gerätekopf durch­strömt das Wasser zuerst den Vorfilter und dann von unten nach oben die übereinanderliegenden Filterma­terialien. Anschließend strömt das Wasser durch das Ausströmrohr oder über den Wasserverteiler zurück in das Aquarium. Als Filtermaterialien dienen Filterschäume unter­schiedlicher Porendichte und Hel-X-Biokörper. Bei einem Gerät mit Heizer wird das Wasser auf dem Weg durch das Filtersystem erwärmt.

ZUGANG ZUM GERÄT

HINWEIS
Für alle Geräte mit Heizer gilt:
Regeln für den vorsichtigen Umgang einhalten.
(→ Vorsichtiger Umgang mit dem Heizer)

Vorsichtiger Umgang mit dem Heizer

Heiße Oberfläche!
VORSICHT
Brandverletzung beim Berühren des Glaskolbens.
Erst den Heizer ausschalten und abkühlen lassen, dann aus dem Wasser nehmen.
VORSICHT
Glasbruchgefahr!
Der Glaskolben des Heizers kann zerbrechen und

Bestimmungsgemäße Verwendung

BioMaster 250/350/600, BioMaster Thermo 250/350/600, "Gerät" genannt, darf ausschließlich wie folgt verwendet werden:
Schnittverletzungen verursachen.
• Vorsichtig mit dem Heizer umgehen.
Erwärmten Heizer abkühlen lassen. Nicht in kaltes
Wasser tauchen, nicht mit kaltem Wasser übergie­ßen.
BioMaster 250/350/600: Wasser filtern und zirku­lieren lassen.
BioMaster Thermo 250/350/600: Wasser erwär­men, filtern und zirkulieren lassen.
• Zum Betrieb mit Süßwasser oder Meerwasser.
Betrieb unter Einhaltung der technischen Daten.
(→ Technische Daten)
12 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0

Heizer ausbauen

Ausbau erforderlich zur Reinigung und Wartung und zum Ausbau des Gerätekopfs. So gehen Sie vor:
5 C
1. Griff hochstellen.
2. Durchlassring mitsamt H eiz er gegen den Uhrzeiger­sinn herausdrehen.

Heizer einbauen

So gehen Sie vor: 5 D
1. Durchlassring mit Heizer im Uhrzeigersinn in das Ge­windeloch drehen. – Wenn der Heizer getauscht wird: Glaskolben mit
Wasser befeuchten und Heizer bis zum Anschlag in den Durchlassring schieben.
2. Netzanschlussleitung in die Kabelführung legen.
3. Griff herunterklappen.

Anschlusseinheit ausbauen

Ausbau erforderlich zur Reinigung und Wartung und zum Ausbau des Gerätekopfs bei angeschlossenen Schläuchen.
So gehen Sie vor: 5 E
1. Hebel auf Position "UNLOCK" schieben. – Der Hebel lässt sich nur bei verriegeltem Vorfilter
bewegen.
– Eingang und Ausgang sind geschlossen.
2. Anschlusseinheit abnehmen.
So gehen Sie vor:

Anschlusseinheit einbaue n

So gehen Sie vor: 5 F
1. Anschlusseinheit aufsetzen und bis zum Anschlag in den Gerätekopf drücken. – Die Stege an der Anschlusseinheit müssen zu den
Aussparungen am Gerätekopf korrekt ausgerich­tet sein.
2. Hebel in Richtung "LOCK" schieben. – Eingang und Ausgang sind geöffnet.

Vorfilter ausbauen

Ausbau erforderlich zur Reinigung und Wartung und zum Ausbau des Gerätekopfs.
So gehen Sie vor: 5 G
1. Hebel auf Position "UNLOCK" schieben. – Eingang und Ausgang werden automatisch ge-
schlossen.
2. Vorfilter herausziehen.
- DE -

Vorfilter einbauen

So gehen Sie vor: 5 H
1. Vorfilter in die Öffnung stecken und kraftvoll bis zum Anschlag in den Gerätekopf drücken. – Die Stege am Vorfilter müssen zu den Aussparun-
gen am Gerätekopf korrekt ausgerichtet sein.
2. Hebel auf das Symbol "Schloss verriegelt" schieben. – D er Vo rfilter ist verriegelt.

Gerätekopf ausbauen

Ausbau erforderlich zur Reinigung und Wartung und zum Wechseln des Filtermaterials.
Voraussetzung:
Der Heizer ist ausgebaut. (→ Heizer ausbauen)
Die Anschlusseinheit ist ausgebaut. (→ An-
schlusseinheit ausbauen)
Der Vorfilter ist ausgebaut. (→ Vorfilter ausbauen)
So gehen Sie vor: 5 I
1. Griff hochstellen.
2. Spannverschlüsse lösen
3. Gerätekopf abnehmen.

Gerätekopf einbauen

So gehen Sie vor: 5 J
1. Dichtung am Gerätekopf auf richtigen Sitz prüfen. – Dichtung reinigen, beschädigte Dichtung erset-
zen.
2. Sicherstellen, dass die Filterkörbe korrekt zusam­mengesetzt und ausgerichtet sind.
3. Gerätekopf auf den Behälter setzen. – Di e Durchlassöffnung für den Vorfilter muss zur
Aussparung in den Filterkörben ausgerichtet sein.
4. Spannverschlüsse verriegeln.
5. Griff herunterklappen.
13
- DE -
BioMaster
250
350
600
50 ¡ ¡ ¡
200
¡

AUFSTELLEN UND ANSCHLIEßEN

Reihenfolge der auszuführenden Arbeiten:
1. Gerätefüße anbringen (→ Gerätefüße montieren)
2. Filtermaterialien vorbereiten (→ Filtermaterial rei­nigen/ersetzen)
3. Optional: OASE HeatUp (Heizer) nachrüsten (→ Hei­zer nachrüsten)
4. Gerät aufstellen. – Gerät neb en oder unter dem Aquarium aufstel-
len. Maximale Förderhöhe beachten. (→ Techni­sche Daten)
5. Anschlüsse herstellen (→ Anschlüsse herstel l en)

Gerätefüße montieren

So gehen Sie vor: 5 K
Gummifüße in die Öffnungen am Behälterboden drehen.

Heizer nachrüsten

BioMaster 250/350/600 ist nachträglich mit OASE Hea­tUp erweiterbar.
Für die Montage ist ein Durchlassring erforderlich (im Lieferumfang enthalten).
25
75 ¡ ¡ ¡
100 150
HeatUp
250 ¡ 300 l
l empfohlen ¡ möglich
– nicht möglich Voraussetzung:
Die Pumpe ist ausgeschaltet. (→ Gerät ausschalten)
HINWEIS Wenn der Filter mit Wasser gefüllt ist, kann beim Ein­führen des Heizers Wasser austreten.
Maßnahmen treffen, um austretendes Wasser auf-
zufangen.
¡ ¡ ¡
¡ ¡ ¡ l ¡ ¡
l
So gehen Sie vor: 5 L
1. Blindstopfen gegen den Uhrzeigersinn herausdre­hen.
2. Heizer bis zum Anschlag in den Durchlassring schie­ben. – Tipp: Glaskolben vor der Montage mit Wasser be-
feuchten.
3. Heizer einbauen. (→ Heizer einbauen)
Anschlüsse herstellen Saugeinheit zusammenbauen
So gehen Sie vor: 5 M
• Saugeinheit zusammenbauen.
• Durchflussmenge einstellen.
Mittels einer Münze den Durchflussregler im
Schlauchadapter auf MAX drehen.
Ausströmeinheit zusammenbauen
So gehen Sie vor: 5 N
Ausströmeinheit zusammenbauen.Alternativ kann statt des Ausströmrohrs der Was-
serverteiler verwendet werden.
Mittels einer Münze den Durchflussregler im Schlauchadapter auf MAX drehen.
Schlauch anschließen
Die Vorgehensweise ist für Eingang (IN) und Ausgang (OUT) identisch.
So gehen Sie vor: 5 O
Saugeinheit und Ausströmeinheit mittels Saugnäpfe im Aquarium befestigen.
5 P
1. Schlauch auf passende Länge kürzen. – Länge so wählen, dass bei der vorgesehenen Auf-
stellung der Schlauch nicht knicken kann.
2. Überwurfmutter auf Schlauchtülle der An­schlusseinheit schrauben.
3. Schlauch auf Schlauchtülle schieben und Überwurf­mutter gegen den Uhrzeigersinn drehen, um den Schlauch zu fixieren.
4. Anderes Schlauchende auf Schlauchtülle an der An­saugeinheit/Ausströmeinheit schieben und Über­wurfmutter gegen den Uhrzeigersinn drehen, um den Schlauch zu fixieren.
14 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0

INBETRIEBNAHME

Bei Erstinbetriebnahme oder nach einer vollständigen Reinigung muss das Filtersystem entlüftet werden. Wenn Behälter, Ansaugeinheit und Schlauch frei von Lufeinschlüssen sind, kann die Pumpe das Wasser selbsttätig durch das Filtersystem fördern. (→ Filtersy- stem entlüften)
HINWEIS Verpackung um Filtermaterial entfernen. Alle Filter­materialien vor der ersten Verwendung mit warmem Leitungswasser gründlich ausspülen, um mögliche Ver­schmutzungen zu entfernen. (→ Filtermaterial reini­gen/ersetzen)

Filtersystem entlüften

Voraussetzung:
Die Pumpe ist ausgeschaltet. (→ Gerät ausschalten) So gehen Sie vor:
5 Q
1. Ansaugknopf drücken und loslassen bis das Wasser
aus dem Becken in den Filter strömt. – Sobald das Wasser über die Ausströmeinheit aus-
tritt, ist der Filter komplett geflutet.

Gerät einschalten

HINWEIS Pumpe darf nicht trockenlaufen!
Pumpe wird zerstört.
Wasserstand und Zirkulation im Filter und im Aqua-
rium regelmäßig kontrollieren.
- DE -
HINWEIS
Brandgefahr durch heiße Oberfläche des Heizers!
Durch die große Hitzeentwicklung werden Heizer und Filter zerstört.
Heizer erst einsc halten, wenn der Filter vollständig mit Wasser gefüllt ist, eingeschaltet ist und das Wasser kontinuierlich zirkuliert.
Erst den Heizer ausschalten und abkühlen lassen, dann aus dem Wasser nehmen.
So gehen Sie vor: 5 R
1. Jede Netzanschlussleitung so verlegen, dass sich eine Tropfschlaufe bildet.
2. Netzanschlussleitung mit dem Stromnetz verbin­den.
Die Pumpe schaltet sofort ein.Luf teinschlüsse im Filter können Geräusche ver-
ursachen. Kurze Zeit nach dem Einschalten ent­weichen die Lufteinschlüsse.
3. Gerät mit Heizer: Wassertemperatur am Heizer ein­stellen und Heizer einschalten. (→ Gebrauchsanlei­tung Heizer).

Gerät ausschalten

So gehen Sie vor:
• Gerät vom Stromnetz trennen.
Gerät mit Heizer: Gerät und Hei zer vom St romnetz
trennen.

Durchflussmenge einstellen

So gehen Sie vor: 5 S
Den Hebel an der Anschlusseinheit verschieben, um die gewünschte Durchflussmenge einzustellen.
"LOCK": Maximale Durchflussmenge "UNLOCK": Kein Durchfluss, Ausgang ist geschlos-
sen.
15
- DE -
Störung
Ursache
Abhilfe
Gerät läuft nicht an
Netzspannung fehlt
Netzspannung überprüfen
Laufeinheit blockiert
Reinigen
Luft im Filter
Filter entlüften. Evtl. Filter seitlich hin und entweichen kann.
Wasserfluss ungenügend
Laufeinheit verschmutzt
Reinigen
Laufeinheit verschlissen
Laufeinheit ersetzen
Durchfluss nicht richtig eingestellt
Einstellung korrigieren
Filterschaum des Vorfilters verschmutzt
Reinigen
Filtermaterial im Behälter verschmutzt
Reinigen
Saugkorb verstopft
Reinigen
Leitungssystem verschmutzt
Saugeinheit, Ausströmeinheit und Schläu­che reinigen
Filterwirkung ungenügend
Filterschaum des Vorfilters verschmutzt
Reinigen
Filterschaum des Vorfilters verschlisse n
Ersetzen
Filtermaterial im Behälter verschmutzt
Reinigen
Filtermaterial im Behälter verschlissen
Ersetzen
Wassererwärmung ungenügend (nur Geräte mit Heizer)
Heizer defekt
Ersetzen
Heizer nicht kalibriert
Kalibrieren
Wassertemperatur am Heizer falsch einge­stellt
Wassertemperatur am Heizer korrigieren Wasserfluss ungenügend
Siehe Störung "Wasserfluss ungenügend"
Filter lässt sich nicht entlüften Ventilgehäuse im Vorfilter verstopft
Ventilgehäuse reinigen
Filter steht nicht unterhalb der Wasserlinie
Filter unterhalb der Wasserlinie aufstellen
Erhöhte Geräuschentwicklung
Luft im Filter
Filter seitlich hin und her bewegen, damit restliche Luft besser entweichen kann
Bereich
Durchzuführende Arbeiten
Filterschaum Vorfilter
(→ Filterschaum Vorfilter reini­gen/ersetzen)
Filtermaterial Behäl­ter
(→ Filtermaterial reinigen/ersetzen)
Heizer HeatUp 25/50/75/
Laufeinheit, Pum­pengehäuse
(→ Laufeinheit reinigen/ersetzen)
Ventilgehäuse Vorfil­ter
(→ Ventilgehäuse Vorfilter reinigen)
Ansauggehäuse Vor­filter
(→ Ansauggehäuse Vorfilter reini­gen)

STÖRUNGSBESEITIGUNG

S

REINIGUNG UND WARTUNG

Gerät bei Bedarf mit klarem Wass er und mit einer weichen Bürste reinigen.
Keine Reinigungsmittel oder chemische Lösungen verwenden. Um Kalkablagerungen zu entfernen, wird OASE PumpClean empfohlen.
Reinigungs- und Austauschzyklen für Filtermateria- lien sind abhängig von Beckengröße und Besatz. Reinigung und Austausch sollten daher nach Bedarf erfolgen, um die volle Filterleistung sicherzustellen.
Falls mehrere Filterschäume vorhanden sind: Filter- schäume zeitversetzt reinigen oder ersetzen. So werden die nützlichen Filterbakterien geschont und können für eine gute biologische Reinigung des Wassers sorgen.
HINWEIS Verpackung um Filtermaterial entfernen. Alle Filter­materialien vor der ersten Verwendung mit warmem Leitungswasser gründlich ausspülen, um mögliche Ver­schmutzungen zu entfernen. (→ Filtermaterial reini­gen/ersetzen)
her bewegen, damit restliche Luft besser
Reinigungs- und Wartungsarbeiten:
100/150/200/250/300
HINWEIS Der Zyklus zur Reinigung des Filtersc haums im Vorfilter verlängert sich, wenn ein gröberer Filterschaum v er­wendet wird.
16 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0
a
Filterschaum 30 ppi
b
Filterschaum 20 ppi
c
Hel-X-Biokörper, immer mit Beutel in die Filter­schale legen
Filterschaum Vorfilter reinigen/ersetzen Voraussetzung
Der Vorfilter ist ausgebaut. (→ Vorfilter ausbauen) So gehen Sie vor:
5 T
1. Gehäuse drehen bis die Rasthaken eingedrückt sind, dann das Gehäuse abziehen.
2. Vorfilterrohr und Filterschäume abziehen.
Bi o M as t er 25 0: 4 Filterschäume.BioMaster 350: 5 Filterschäume. Bi o M as t er 60 0: 6Filterschäume.
3. Filterschäume unter warmem Was ser spülen. Falls erforderlich, Filterschäume ersetzen.
4. Vorfilter in umgekehrter Reihenfolge zusammen­bauen. – Die Rasthaken müssen in das Gehäuse einrasten.

Filtermaterial reinigen/ersetzen

5 U Filtermaterialien bei Auslieferung:
Voraussetzung
Der Gerätekopf ist abgenommen. (→ Gerätekopf ausbauen)
So gehen Sie vor: 5 U
1. Alle Filterkörbe herausnehmen.
2. Filterkörbe und Behälter reinigen.
3. Filtermaterial mit Wasser aus dem Aquarium aus­spülen. – F alls erforderlich, Filtermaterial erset zen. Neues
Filtermaterial vor der ersten Verwendung mit warmem Leitungswasser gründlich ausspülen.
4. Teile in umgekehrter Reihenf olge in den Behälter setzen. – D ie Filterkörbe sorgfältig in die untere Ausspa-
rung im Behälter setzen. Dabei die Position des Vorfilters beachten.
– Di e Filterabdeckung muss auf dem Filterschaum
im obersten Filterkorb liegen.
5. Gerät in umgekehrter Reihenfolge zusammen­bauen.
Laufeinheit reinigen/ersetzen Voraussetzung
Der Gerätekopf ist abgenommen. (→ Gerätekopf ausbauen)
- DE -
So gehen Sie vor: 5 V
1. Entlüftungselement abziehen.
2. Pumpendeckel gegen den Uhrzeigersinn drehen (Bajonettverschluss) und abnehmen.
3. Laufeinheit entnehmen und reinigen. Falls erforder­lich, ersetzen.
4. Laufeinheit einbauen, Pumpendeckel aufsetzen und verriegeln (im Uhrzeigersinn drehen). – Auf korrekten Sitz der beiden Gummilager ach-
ten.
5. Gerät in umgekehrter Reihenfolge zusammen­bauen.

Ventilgehäuse Vorfilter reinigen

Das Ventilgehäuse muss erst gereinigt werden, wenn die Entlüftung nicht funktioniert, obwohl zuvor die Fil­terschäume des Vorfilters gereinigt wurden.
Voraussetzung
Der Vorfilter ist ausgebaut. (→ Vorfilter ausbauen)
So gehen Sie vor: 5 W
1. Drei Laschen jeweils über die Rastnasen schieben und das Ventilgehäuse abziehen. – Gegebenenfalls die Laschen mittels eines Schrau-
bendrehers vorsichtig anheben.
2. Ventildichtung und beide Ventilklappen abnehmen. Alle Teile reinigen.
3. Ventilgehäuse in umgekehrter Reih enfolge zusam­menbauen. – Die eingebauten Ventilklappen müssen sich
leichtgängig bewegen lassen.
Hinweis: Die Öffnung in der Ventildichtung muss
zur Öffnung im Ansauggehäuse ausgerichtet sein.

Ansauggehäuse Vorfilter reinigen

Das Ansauggehäuse muss erst gereinigt werden, wenn die Entlüftung nicht funktioniert, obwohl zuvor Filter­schäume und Ventilgehäuse des Vorfilters gereinigt wurden.
Voraussetzung
Der Vorfilter ist ausgebaut. (→ Vorfilter ausbauen)
VORSICHT
Starke Feder im Ansauggehäuse, die wie ein Geschoss wirken kann. Verletzungsgefahr durch umherfliegende Teile!
Beim Öffnen den Ansaugknopf nicht auf Personen richten.
Ansaugknopf gut festhalten.
17
- DE -
Mit Originalteilen von OASE bleibt das Gerät sicher und arbe Ersatzteilzeichnungen und Ersatzteile finden Sie auf un­serer Internetseite.
www.oase-livingwater.com/ersatzteile
Beschreibung
BioMaster, BioMaster Thermo
250
350
600
Bemessungsspannung
V AC
230
230
230
Netzfrequenz
Hz
50
50
50
Schutzart IPX4
IPX4
IPX4
Leistungsaufnahme Filter
W
15
18
22
BioMaster Thermo
Leistungsaufnahme Heizer
W
150
200
300
Förderleistung
maximal
l/h
900
1100
1250
Förderhöhe
maximal m 1,3
1,4
1,8
Wassersäule
maximal m 1,8
1,8
1,8
Volumen Filter
l
4,4
5,6
6,8
Volumen Vorfilter
l
0,4
0,5
0,6
Empfohlen für Aquarium Volumen
l
250
350
600
Länge Netzanschlussleitung
m
1,5
1,5
1,5
Anschluss Schlauchtüllen
Durchmesser
mm
17
17
17
Abmessungen
Länge
mm
240
240
240
Breite
mm
240
240
240
Höhe
mm
370
425
480
Gewicht
kg
4,1
4,5
5,0
Geschützt vor Spritzwasser von allen Seiten
Schutzklasse II, Schutzisolierung, die im Fehlerfall Spannung führen kann
Im Innenraum verwenden
Nicht mit normalem Hausmüll entsorgen
Gebrauchsanleitung lesen und beachten
So gehen Sie vor: 5 X
1. Rasthaken eindrücken, festhalten und den Ver­schlussring gegen den Uhrzeigersinn drehen (Bajo­nettverschluss).
2. Ansaugknopf vorsichtig abnehmen bis die Feder entspannt ist.
3. Ansaugknopf und Feder entnehmen.
4. Ansauggehäuse reinigen.
5. Ansauggehäuse in umgekehrter Reihenfolge zusam­menbauen.

ERSATZTEILE

itet weiterhin zuverlässig.

VERSCHLEIßTEILE

• Filtermaterial
• Laufeinheit
• Saugnäpfe

ENTSORGUNG

HINWEIS
Dieses Gerät darf nicht als Hausmüll entsorgt werden.
Gerät durch Abschneiden der Kabel unbrauchbar machen und über das dafür vorgesehene Rücknah­mesystem entsorgen.

TECHNISCHE DATEN

SYMBOLE AUF DEM GERÄT

18 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0

- EN -

Translation of the original Operating Instructions
WARNING
This unit can be used by chil- dren aged 8  and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are super­vised or have been instructed on how to use the unit in a safe way and they understand the hazards involved.
Do not allow children to play with the unit.
Only allow children to carry out cleaning and user mainte­nance under supervision.
Switch off all units in the aquarium or disconnect the power plugs of all units before reaching into the water.
Do not use the unit if electrical cables or housings are dam­aged.
Only connect the unit if the electrical data of the unit and the power supply correspond. The unit data is to be found on the unit type plate, on the packaging or in this manual.
Disconnect the power plug be- fore carrying out any work on the unit.
- EN -
SAFETY INFORMATION
• Never operate the unit if the housing is defective!
Never operate the unit if any electrical cables are
defective!
• Never carry or pull the unit by the electrical cable.
Route cables such that they are protected from
damage and do not present a tripping hazard.
Only open the unit housing or its attendant compo- nents if this is explicitly specified in th e operatin g in­structions.
Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an authorised customer service point or, if in doubt, the manufacturer.
Only use original spare parts and accessories for the unit.
• Never carry out technical changes to the unit.
• Protect the plug connection from moisture.
• Only connect the unit to a correctly fitted socket.

Warnings used in these instructions

The warning information is categorised by signal words, which indicate the extent of the hazard.
WARNING
• Indicates a possibly hazardous situation.
Non-observance may lead to death or serious inju-
ries.
NOTE Information for the purpose of clarification or for pre­venting possible damage to assets or to the environ­ment.

Cross-references used in these instructions

5 A reference to a figure, e.g. figure A.
Reference to another section.
19
- EN -
5 A
BioMaster Thermo
1
BioMaster Thermo 250: HeatUp 150 BioMaster Thermo 350: HeatUp 200 BioMaster Thermo 600: HeatUp 300
2
Operating instructions HeatUp 25/50/75/100/ 150/200/250/300
BioMaster, BioMaster The rmo
3
Operating instructions BioMaster 250/3 BioMaster Thermo 250/350/600
4
Holding ring for HeatUp assembly
5
Blind plug
6
Handle, when the handle is hinged down there are two fasteners (10), locked
7
Unit head
8
Pre-filter with suction button
9
Connection unit with hose connectors, outlet and in­let
10
Fastener
11
Container, filled with filter media
12
Rubber feet
5 B
Suction unit, flow-out unit
Quantity
1
Suction pipe
1 2 Hose 1 3
Flow-out pipe
2
4
Suction cup
5
5
Hose adapter, adjustable
2 6 Adapter, suction pipe
1
7
Suction basket
1
8
Terminal
5 9 Angle piece
1
10
Union nut
4
11
Short hose section as connecting piece for flow-out pipes (3)
1
12
Water distributor
1
13
Cover cap
1

PRODUCT DESCRIPTION

Scope of delivery

50/600,
The following restrictions apply to the unit:
Only use indoors and for aquaristic purposes in the home (not for commercial use).
Only operate with water at a water temperature of +4 °C to +35 °C.

Function description

Drawn in by a pump in the unit head, the water first flows through the pre-filter then from the bottom to the top through the superimposed layers of fi lter me­dia. The water then flows back into the aquarium via the flow-out pipe or water distributor. Foam filters with different pore densities, and Hel-X bio-elements serve as filter media. In units with heater, the water is heated during its pas­sage through the filter system.

ACCESSING THE UNIT

NOTE
The following applies to all units with heater:
Adhere to the rules for careful handling. (→ Careful handling of the heater)

Careful handling of the heater

Hot surface!
CAUTION
Risk of burns when touching the glass bulb.
Switch off the heater and allow it to cool down be- fore removing it from the water.
CAUTION
Risk of breaking the glass!
The glass bulb of the heater can break and cause cuts.
• Take care when handling the heater.

Intended use

Allow the heater to cool down first. Do not immerse it in cold water or pour cold water over it.
BioMaster 250/350/600, BioMaster Thermo 250/350/600, referred to as "uni t", may only be used as specified in the following:
BioMaster 250/350/600: Water filtering and recir- culation.
BioMaster Thermo 250/350/600: Water heating, filtering and recirculation.
• For operation with freshwater or saltwater.
Operate in accordance with instructions. (→ Techni-
cal data)
20 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0

Removing the heater

The heater has to be removed for cleaning and mainte­nance, and for removing the unit head. How to proceed:
5 C
1. Hinge up the handle.
2. Unscrew the holding ring together with the heater counter-clockwise.

Fitting the heater

How to proceed: 5 D
1. Screw the holding ring with heater clockwise into the threaded hole. – T o exchange the heater: Moisten the gla ss bulb
with water and push the heater into the holding ring as far as it goes.
2. Place the power connection cable into the cable guide.
3. Hinge the handle down.

Removing the connection unit

The heater has to be removed for cleaning and mainte­nance, and for removing the unit head when hoses are connected.
How to proceed: 5 E
1. Push the lever to the "UNLOCK" position. – T he lever can only be moved when the pre-filter
is locked.
– The inlet and outlet are closed.
2. Remove the connection unit.
How to proceed:

Fitting the connection unit

How to proceed: 5 F
1. Fit the connection unit and push it into the unit head as far as it goes. – Ensure that the ridges on the connection unit are
correctly aligned to the recesses on the unit head.
2. Push the lever in the direction "LOCK". – The inlet and outlet are open.

Removing the pre-filter

It has to be removed for cleaning and maintenance and for removing the unit head.
How to proceed: 5 G
1. Push the lever to the "UNLOCK" position. – The inlet and outlet are closed automatically.
2. Pull out the pre-filter.
- EN -

Fitting the pre-filter

How to proceed: 5 H
1. Fit the pre-filter into the opening and firmly push it into the unit head as far as it goes. – Ensure t hat the ridges on the pre-filter are cor-
rectly aligned to the recesses on the unit head.
2. Push the lever to the "padlock closed" symbol. – The pre-filter is locked.

Dismantling the unit head

It has to be removed for cleaning and maintenance and for changing the filter media.
Prerequisite:
The heater has been removed. (→ Removing the heater)
The connection unit has been removed. (→ Remo- ving the connection unit)
The pre-filter has been removed. (→ Removing t he pre-filter)
How to proceed: 5 I
1. Hinge up the handle.
2. Undo the fasteners.
3. Remove the unit head.

Fitting the unit head

How to proceed: 5 J
1. Check that the seal on the unit head is correctly po­sitioned. – Clean the seal, replace it if damaged.
2. Ensure that the filter baskets ar e correctly assem­bled and aligned.
3. Fit the unit head onto the container. – Ensure that the opening for the pre-filter is
aligned to the recess in the filter baskets.
4. Lock the fasteners in place.
5. Hinge the handle down.
21
- EN -
BioMaster
250
350
600
50 ¡ ¡ ¡
200
¡

INSTALLATION AND CONNECTION

Order of tasks to be carried out:
1. Fit the unit feet (→ Fitting the unit feed)
2. Prepare the filter media (→ Cl eaning/replacing the filter media)
3. As an option: OASE HeatUp Retrofitting (heater) (→ Retrofitting the heater)
4. Install the unit. – I nstall the unit next to or under the aquarium.
Note the maximum head height. (→ Technical data)
5. Establish the connections (→ Establishing the con- nections)

Fitting the unit feed

How to proceed: 5 K
Twist the rubber feet into the openings of the con- tainer base.

Retrofitting the heater

BioMaster 250/350/600 can be retrofitted with OASE HeatUp.
A holding ring is required for fitting (provided in the delivery scope).
25
75 ¡ ¡ ¡
100 150
HeatUp
250 ¡
¡: Suitable l: Particularly recommended
300 l
Prerequisite:
The pump is switched off. (→ Switching off the unit)
NOTE When the filter is filled with water, water may spill when the heater is inserted.
Take measures to collect any spillage.
¡ ¡ ¡
¡ ¡ ¡ l ¡ ¡
l
How to proceed: 5 L
1. Unscrew the blind plug counter-clockwise and re­move.
2. Push the heater into the holding ring as far as it goes. – T ip: Moisten the glass bulb with water before in-
serting.
3. Fit the heater. (→ Fitting the heater)
Establishing the connections Assembling the suction unit
How to proceed: 5 M
• Assemble the suction unit.
• Set the flow rate.
Use a coin to turn the flow regul ator in the hose
adapter to MAX.
Assembling the flow-out unit
How to proceed: 5 N
Assemble the flow-out unit. T he water distributor can be used in stead of the
flow-out pipe.
Use a coin to turn the flow regul ator in the hose adapter to MAX.
Connecting the hose
The procedure is identical for the inlet (IN) and outlet (OUT).
How to proceed: 5 O
Fasten the suction unit and flow-out unit in the aquarium using suction cups.
5 P
1. Shorten the hose to the required length. – Chose the length s o that the hose cannot kink in
the intended installation position.
2. Screw the union nut onto the hose connector of the connection unit.
3. Push the hose onto the hose connector and turn the union nut counter-clockwise to fix the hose in place.
4. Push the other end of the hose ont o the hose con­nector at the suction unit/flow-out unit and turn the union nut counter-clockwise to fix the hose in place.
22 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0

COMMISSIONING/START-UP

For initial start-up or after thorough cleaning, it is nec­essary to expel air from the filter system. When th e container, suction unit and hose are free of trapped air, the pump can convey the water by itself through the filter system. (→ Expelling air from the filter sys­tem)
NOTE Thoroughly rinse out all filter material with warm tap water before using for the first time in order to remove any soiling. (→ Cleaning/replacing the filter media)

Expelling air from the filter system

Prerequisite:
The pump is switched off. (→ Switching off the unit) How to proceed:
5 Q
1. Press the suction button and release it until the wa-
ter flows out of the tank into the filter. – The filter is completely flooded when water
emerges from the flow-out unit.

Switching on the unit

NOTE Ensure that the pump never runs dry!
The pump will be destroyed.
Regularly check the water level and circulation in
the filter and in the aquarium.
- EN -
NOTE
Risk of fire due to the hot surface of the heater!
The heater and filter can be destroyed by the gener­ated heat.
Do not switch the heater on until the filter is com- pletely filled with water, switched on and the water is continuously circulated.
Switch off the heater and allow it to cool down be- fore removing it from the water.
How to proceed: 5 R
1. Route each power connection cable such that it forms a drip loop.
2. Connect the power connection cable to the power supply.
The pump will switch on immediately.Trapped air in the filter can cause noise. The
trapped air escapes shortly after the pump starts up.
3. Unit with heater: Set the water temperature on the heater and switch on the heater. (→ Heater opera­ting manual).

Switching off the unit

How to proceed:
• Disconnect the unit from the power supply
Unit with heater: Disconnect the un it and heater
from the power supply

Setting the flow rate

How to proceed: 5 S
Move the lever on the connection unit to set the de- sired flow rate
"LOCK": Maximum flow rate "UNLOCK": No flow, the outlet is closed.
23
- EN -
Malfunction
Cause
Remedy
Unit does not start up.
No mains voltage
Check the mains voltage.
Impeller unit blocked
Clean
Air in the filter
Vent the filter. Move the filter from side to to escape.
Water flow insufficient
Impeller unit soiled
Clean
Impeller unit worn
Replace the impeller unit.
The flow is not correctly set.
Correct the setting.
Foam filter of the pre-filter soiled
Clean
Filter media in the container soiled
Clean
Suction basket clogged
Clean
Pipework soiled
Clean suction unit, flow-out unit and hoses.
Insufficient filtering performance
Foam filter of the pre-filter soiled
Clean
Foam filter of the pre-filter worn
Replace
Filter media in the container soiled
Clean
Filter media in the container worn
Replace
Insufficient water heating (only units with heater)
Heater defective
Replace
Heater not calibrated
Calibrate
Water temperature incorrectly set on the heater
Correct the water temperature setting on the heater.
Water flow insufficient
See malfunction "Water flow insufficient"
The filter cannot be vented.
Valve box in the pre-filter blocked
Clean the valve box.
Filter is not below the surface of the water.
Install the filter below the surface of the water.
Increased noise
Air in the filter
Move the filter from side to side to allow the remaining air to escape.
Area
Tasks to be carried out
Foam filter, pre-filter
(→ Cleaning/replacing the foam fil­ter of the pre-filter)
Filter media, contai­ner
(→ Cleaning/replacing the filter me­dia)
Heater
HeatUp 25/50/75/
Impeller unit, pump casing
(→ Cleaning/replacing the impeller unit)
Valve box, pre-filter
(→ Cleaning the valve box of the pre­filter)
Suction chamber, pre­filter
(→ Cleaning the suction chamber of the pre-filter)

REMEDY OF FAULTS

S

MAINTENANCE AND CLEANING

If necessary, clean with clear water using a soft brush.
Do not use cleaning agents or chemical solutions. We recommend using OASE Pu mpClean for remov­ing calcium deposits.
Cleaning and replacement cycles for filter media are dependent on the size of the aquarium and the number of fish. Therefore, it is necessary t o clean and replace the filter media as required to ensure optimum filter performance.
If there are several foam filters: Clean or replace the foam filters at different times. Thi s saves enough useful bacteria to ensure good biological filtration of the water.
NOTE Thoroughly rinse out all filter material with warm tap water before using for the first time in order to remove any soiling. (→ Cleaning/replacing the filter media)
side, if necessary, to allow the remaining air
Cleaning and maintenance work:
100/150/200/250/300
NOTE The cycle for cleaning the foam filter in the pre-filter is longer if a coarser foam filter is used.
24 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0
a
Foam filter 30 ppi
b
Foam filter 20 ppi
c
Hel-X bio-elements, always place them contained in the bag into the strainer casing
Cleaning/replacing the foam filter of the pre-filter Prerequisite
The pre-filter has been removed. (→ Removing t he pre-filter)
How to proceed: 5 T
1. Turn the casing until the locking hooks are pushed in, then pull off the casing.
2. Remove the pre-filter pipe and foam filters.
– Bi o M as t er 25 0: 4 foam filters. – Bi o M as t er 35 0: 5 foam filters. – Bi o M as t er 60 0: 6 foam filters
3. Rinse the foam filters in warm water. I f necessary, replace the foam filters.
4. Assemble the pre-filter in the reverse order. – Ensure that t he locking hooks lock in place in the
casing.

Cleaning/replacing the filter media

5 U Filter media on delivery:
Prerequisite
The unit head is removed. (→ Dismantling the unit head)
How to proceed: 5 U
1. Remove all filter baskets.
2. Clean the filter baskets and container.
3. Use water to flush the filter media from the aquar­ium. – I f necessary, replace the filter media. Rinse the
new filter media thoroughly with warm tap water prior to its first use.
4. Insert the parts in the cont ainer in the reverse or­der. – C arefully fit the filter baskets in the bottom re-
cess in the container. Correctly posit ion the pre­filter.
– Ensure t hat the filter cover is positioned on the
foam filter in the top filter basket.
5. Reassemble the unit in the reverse order.
Cleaning/replacing the impeller unit Prerequisite
The unit head is removed. (→ Dismantling the unit head)
- EN -
How to proceed: 5 V
1. Pull off the venting element.
2. Turn the pump lid counter-clockwise (bayonet lock) and remove.
3. Remove the impeller unit and clean. If necessary, re­place.
4. Fit the impeller unit, replace the pump lid and lock (turn clockwise). – Ensure that the two rubber bearings are correctly
seated.
5. Reassemble the unit in the reverse order.

Cleaning the valve box of the pre-filter

The valve box only has to be cleaned if vent ing does not function even though the foam filters of the pre­filter have been cleaned.
Prerequisite
The pre-filter has been removed. (→ Removing the pre-filter)
How to proceed: 5 W
1. Undo the fasteners and pull off the valve box. – I f necessary, carefully lift the fasteners using a
screwdriver.
2. Remove the valve seal and both valve flaps. Clean all parts.
3. Assemble the valve box in the reverse order. – Ensure t hat the fitted valve flaps can be easily
moved.
Note: Ensure that the opening in the valve seal is
precisely aligned to the opening in the suction chamber.

Cleaning the suction chamber of the pre-filter

The suction chamber only has to be cleaned if venting does not function even though the f oam filters and valve box of the pre-filter have been cleaned.
Prerequisite
The pre-filter has been removed. (→ Removing t he pre-filter)
CAUTION
There is a strong sprin g in the suctio n chamber that can act like a projectile. Risk of injury due to parts flying around
When opening the suction button, do not point it at persons.
Firmly hold the suction button.
25
- EN -
The use of original parts from OASE ensures continued safe and reliable oper Please visit our website for spare parts drawings and spare parts.
www.oase-livingwater.com/spareparts
Description
BioMaster, BioMaster The rmo
250
350
600
Rated voltage
V AC
230
230
230
Mains frequency
Hz
50
50
50
Protection type
IPX4
IPX4
IPX4
Power consumption, filter
W
15
18
22
BioMaster Thermo
Power consumption, heater
W
150
200
300
Flow rate
Max.
l/h
900
1100
1250
Head height
Max. m 1.3
1.4
1.8
Max. head height
Max. m 1.8
1.8
1.8
Filter volume l 4.4
5.6
6.8
Pre-filter volume
l
0.4
0.5
0.6
Recommended for an aquarium volume of
l
250
350
600
Length of power connection cable
m
1.5
1.5
1.5
Connection of hose connec­tors
Diameter
mm
17
17
17
Dimensions
Length
mm
240
240
240
Width
mm
240
240
240
Height
mm
370
425
480
Weight
kg
4.1
4.5
5.0
Splash-water protected on all sides.
Protection class II, protection insulation which could become live in the event of a fault.
For use indoors.
Do not dispose of with household wa s t e .
Read and adhere to the instructions for use.
How to proceed: 5 X
1. Press in the engagement hooks, hold and turn the locking ring counter-clockwise (bayonet lock).
2. Carefully lift the suction button until the tension of the spring is relieved.
3. Remove the suction button and spring.
4. Clean the suction chamber.
5. Assemble the suction chamber in the reverse order.

SPARE PARTS

ation of the unit.

WEAR PARTS

• Filtration medium
• Impeller unit
• Suction cups

DISPOSAL

NOTE
Do not dispose of this unit with domestic waste.
Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided for this purpose.

TECHNICAL DATA

SYMBOLS ON THE UNIT

26 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0

- FR -

Traduction de la notice d'emploi originale
AVERTISSEMENT
Dans le cas où cet appareil se- rait utilisé par des mineurs de moins de 8 ans ainsi que par des personnes souffrant d'un handicap mental ou plus géné­ralement par des personnes manquant d'expérience, un adulte averti devra être pré­sent, qui renseignera le mi­neur ou la personne fragilisée concernée sur le bon emploi de ce matériel.
Les enfants ne doivent pas jouer avec cet appareil.
Ne pas laisser un enfant sans surveillance pour le nettoyage ou l'entretien.
Avant d'entrer dans l'eau, cou- per tous les appareils se trou­vant dans l'aquarium ou dé­brancher la fiche secteur.
Ne pas utiliser l'appareil lors- que les câbles électriques ou les boîtiers sont endommagés.
Ne brancher l'appareil que lorsque les caractéristiques électriques de l'appareil et de l'alimentation électrique cor­respondent. Les caractéris­tiques de l'appareil sont indi­quées sur la plaque signalé­tique de l'appareil, sur l'embal­lage ou dans cette notice d'emploi.
Débrancher la prise de secteur avant d'exécuter des travaux sur l'appareil.
- FR -
CONSIGNES DE SÉCURITÉ
• Ne pas utiliser l'appareil avec un boîtier défectueux.
En cas de câbles électriques défectueux, il est inter-
dit d'utiliser l'appareil.
Ne pas porter ou tirer l'appareil par les câbles élec- triques.
Poser les câbles de manière à ce qu'ils soient proté- gés contre d'éventuels endommagements et vei ller à ce que personne ne puisse trébucher.
N'ouvrir le boîtier de l'appareil ou des éléments s 'y rapportant que si cela est expressément sollicité dans la notice d'emploi.
Exécuter des travaux sur l'appareil uniquement si ces derniers sont décrits dans la notice d'emploi. S'il est impossible de remédier aux problèmes, contac­ter le SAV agréé ou en cas de doute le constructeur.
N’utiliser que des pièces de rechange et des acces- soires d’origine pour l’appareil.
Ne jamais procéder à des modifications techniques sur l’appareil.
Protéger les raccordements à fiche contre l'hu mi- dité.
Raccorder l'appareil uniquement à une prise instal- lée de manière réglementaire.

Avertissements dans cette notice d'emploi

Dans cette notice, les avertissements sont classés par mots de signalisation qui indiquent l'ampleur du risque.
AVERTISSEMENT
• signale une situation éventuellement dangereuse.
Le non-respect risque d'entraîner la mort ou des
blessures graves.
REMARQUE Informations permettant d’assurer une meilleure compréhension et d’éviter des dommages matériels ou environnementaux.

Références dans cette notice d'emploi

5 A Renvoi à l'illustration, p. ex. Figure A.
Renvoi à un autre chapitre.
27
- FR -
5 A
BioMaster Thermo
1
BioMaster Thermo 250 : HeatUp 150 BioMaster Thermo 350 : HeatUp 200 BioMaster Thermo 600 : HeatUp 300
2
Notice d'emploi HeatUp 25/50/75/100/ 150/200/250/300
BioMaster, BioMaster The rmo
3
Notice d'emploi BioMaster 250/350/600, BioMaster Thermo 250/350/600
4
Anneau de passage pour montage HeatUp
5
Obturateur
6
Poignée, lorsque la poignée est rabattue deux fer­metures à genouillère (10) sont verrouillées.
7
Tête d'appareil
8
Préfiltre avec bouton poussoir d'aspiration
9
Unité de raccordement avec raccords de tuyau en­trée et sortie
10
Fermeture à genouillère
11
Récipient, rempli de matériau de filtration
12
Pieds en caoutchouc
5 B
Unité d'aspiration, unité de rejet
Nombre
1
Canne d'aspiration
1 2 Tuyau 1 3
Canne de rejet
2
4
Ventouse
5
5
Adaptateur de flexible, réglable
2 6 Adaptateur canne d'aspiration
1
7
Panier d'aspiration
1
8
Clip 5 9
Pièce coudée
1
10
Écrou d'accouplement
4
11
Morceau de tuyau en tant que pièce de raccordement pour cannes de rejet (3)
1
12
Distributeur d'eau
1
13
Bouchon
1

DESCRIPTION DU PRODUIT

Fourniture

Les restrictions suivantes sont valables pour l'appareil :
A utiliser uniquement à l'intérieur et à des fins d'aquariophilie privée.
A utiliser uniquement avec de l'eau à une tempéra- ture entre +4 °C et +35 °C.

Description des fonctions

L'eau aspirée par une pompe dans la tête d'appareil circule d'abord dans le préfiltre, et en suite de bas en haut dans les matériaux de filtration superposés. Puis, l'eau s'écoule à travers la canne de rejet ou à travers le distributeur d'eau pour retourner dans l'aquarium. Des mousses filtrantes de pores de densités diffé­rentes et des bioéléments HEL-X servent de matériaux de filtration. Pour un appareil muni d'un chauffage, l'eau est chauf­fée pendant sa circulation à travers le système de fil­tration.

ACCES A L'APPAREIL

REMARQUE
Valable pour tous les a ppareils pourvus d'un c hauf­fage :
Respecter les règles pour une manipulation pru- dente. (→ Manipulation prudente du chauffage)

Manipulation prudente du chauffage

Surface brûlante !
ATTENTION
Risque de blessures par brûlure en cas de contact avec le tube de verre.
Éteindre et laisser refroidir le chauffag e avant de le sortir de l'eau.

Utilisation conforme à la finalité

BioMaster 250/350/600, BioMaster Thermo 250/350/600, appelé par la su ite «a pparei l», doit être utilisé exclusivement comme suit :
BioMaster 250/350/600 : Filtrer l'eau et laisser cir­culer.
BioMaster Thermo 250/350/600 : Chauffer l'eau, la
ATTENTION
Risque de bris de verre !
Le tube de verre du chauffage peut casser et causer des blessures par coupure.
• Manipuler le chauffage avec précaution.
Laisser refroidir le chauffage chaud. Ne pas le plon-
ger dans l'eau froide et ne pas l'arroser avec de l'eau froide.
filtrer, et la faire circuler.
Pour une exploitation en eau douce ou en eau de mer.
Exploitation dans le respect des données tech- niques. (→ Caractéristiques techniques)
28 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0

Démontage du chauffage

Démontage nécessaire au nettoyage et à l'entretien, et pour le démontage de la tête de l'appareil. Voici comment procéder :
5 C
1. Lever la poignée.
2. Dévisser l'anneau de passage avec le chauffage dans le sens anti-horaire.

Montage du chauffage

Voici comment procéder : 5 D
1. Visser l'anneau de passage avec le chauffage dans le trou taraudé dans le sens horaire. – Lorsque le chauffage est remplacé : Hum idifie r le
tube de verre avec de l'eau et glisser le chauffage dans l'anneau de passage jusqu'à la butée.
2. Poser le câble de raccordement dans la conduite de câble.
3. Rabattre la poignée.

Démontage de l'unité de raccordement

Démontage nécessaire au nettoyage et à l'entretien, et pour le démontage de la tête d e l'appareil lors de tuyaux raccordés.
Voici comment procéder : 5 E
1. Pousser le levier en position "UNLOCK". – Le levier se laisse uniquement déplacer lorsque le
préfiltre est verrouillé.
– L'entrée et la sortie sont fermées.
2. Retirer l'unité de raccordement.
Voici comment procéder :

Montage de l'unité de raccordement

Voici comment procéder : 5 F
1. Mettre l'unité de raccordement en place et l'enfon­cer jusqu'à la butée dans la tête de l'appareil. – L es ailettes de l'unité de raccordement doivent
être correctement orientées par rapport aux en­coches de la tête de l'appareil.
2. Pousser le levier en direction de "LOCK". – L'entrée et la sortie sont ouvertes.

Démontage du préfiltre

Démontage nécessaire au nettoyage et à l'entretien, et pour le démontage de la tête de l'appareil.
Voici comment procéder : 5 G
1. Pousser le levier en position "UNLOCK". – L 'entrée et la sortie sont automatiquement fer-
mées.
2. Sortir le préfiltre.
- FR -

Montage du préfiltre

Voici comment procéder : 5 H
1. Insérer le préfiltre dans l'ouvertur e et appuyer fer­mement dessus jusqu'à la butée dans la tête de l'ap­pareil. – Les ailettes du préfiltre doivent être correcte-
ment orientées par rapport aux encoches de la tête de l'appareil.
2. Pousser le levier sur le symbole "cadenas fermé". – Le préfiltre est verrouillé.

Démontage de la tête d'appareil

Démontage nécessaire au nettoyage et à l'entretien, et pour le changement du matériau de filtration.
Prérequis :
Le chauffage est démonté. (→ Démontage du chauf- fage)
L'unité de raccordement est démontée. (→ Démon- tage de l'unité de raccordement)
Le préfiltre est démonté. (→ Démontage du pré- filtre)
Voici comment procéder : 5 I
1. Lever la poignée.
2. Détacher les fermetures à genouillère
3. Retirer la tête de l'appareil.

Montage de la tête d'appareil

Voici comment procéder : 5 J
1. Vérifier que le j oint est bien en pl ace sur la tête d e l'appareil. – Nettoyer le joint, remplacer le joint endommagé.
2. S'assurer que les paniers de filtration sont correcte­ment assemblés et orientés.
3. Placer la tête de l'appareil sur le récipient. – L'ouverture de pas sage pour le préfiltre doit être
orientée par rapport à l'évidement dans les pa­niers de filtration.
4. Verrouiller les fermetures à genouillère.
5. Rabattre la poignée.
29
- FR -
BioMaster
250
350
600
25
¡ ¡
150
¡ ¡

MISE EN PLACE ET RACCORDEMENT

Ordre de réalisation des travaux :
1. Montage des pieds de l'appareil (→ Montage des pieds de l'appareil)
2. Préparation des matériaux de filtration (→ Net­toyage/Remplacement du matériau de filtration)
3. Option : OASE HeatUp Compléter (chauffage) (→ Compléter le chauffage)
4. Mise en place de l'appareil. – P lacer l'appareil à côté de l 'aquarium ou en-des-
sous de l'aquarium. Respecter la hauteur de re­foulement maximale. (→ Caractéristiques tech­niques)
5. Effectuer les raccordements (→ Effectuer les rac­cordements)

Montage des pieds de l'appareil

Voici comment procéder : 5 K
Visser les pieds en caoutchouc dans les ouvertures sur le fond du récipient.

Compléter le chauffage

BioMaster 250/350/600 peut être complété ultérieu­rement avec OASE HeatUp .
Un anneau de passage est nécessaire au montage (inclus dans la livraison).
¡
50 75
100
HeatUp
200 l ¡ 250 ¡
¡: approprié l: particulièrement recommandé
300
Prérequis :
La pompe est hors circuit. (→ Déconnexion de l'ap- pareil)
REMARQUE De l'eau peut s'écouler lors de l'introduction du chauf­fage lorsque le filtre est complètement rempli d'eau.
Prendre des mesures pour recueillir l'eau qui
s'écoule.
¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ l
l
Voici comment procéder : 5 L
1. Dévisser le bouchon obturateur dans le sens anti­horaire.
2. Glisser le chauffage jusqu'à la butée dans l'anneau de passage. – Conseil : Humidifier le tube de verre avec de l'eau
avant le montage.
3. Monter le chauffage. (→ Montage du chauffage)
Effectuer les raccordements Assemblage de l'unité d'aspiration
Voici comment procéder : 5 M
• Assemblage de l'unité d'aspiration.
• Régler le débit.
Tourner à l'aide d'une pièce de monnaie le régula-
teur de débit dans l'adaptateur de flexible sur MAX .
Assemblage de l'unité de rejet
Voici comment procéder : 5 N
Assemblage de l'unité de rejet.Le distributeur d'eau peut être utilisé en tant
qu'alternative à la canne de rejet.
Tourner à l'aide d'une pièce de monnaie le régula- teur de débit dans l'adaptateur de flexible sur MAX .
Raccordement du tuyau
La manière de procéder est identique pour l'entrée (IN) et pour la sortie (OUT).
Voici comment procéder : 5 O
Fixer l'unité d'aspiration et l'unité de rejet à l'aide des ventouses dans l'aquarium.
5 P
1. Raccourcir le tuyau à la longueur appropriée. – Choisir la longueur de sorte que le tuyau ne
puisse pas plier lors de la pose à l' emplacement prévu.
2. Visser l'écrou de raccord sur l e raccord d e tu yau de l'unité de raccordement.
3. Pousser le tuyau sur le raccord de tuyau et visser l'écrou de raccord dans le sens anti-horaire pour fixer le tuyau.
4. Pousser l'autre extrémité du tuyau sur le raccord de tuyau à l'unité d'aspiration/l'unité de rejet, et visser l'écrou de raccord dans le sens anti-horaire pour fixer le tuyau.
30 BioMaster 250/350/600, BioM as t er Th erm o 25 0/ 35 0/ 60 0
Loading...
+ 158 hidden pages