Oase AquaMax Eco Classic 3600, AquaMax Eco Classic 1900, AquaMax Eco Classic 1200, AquaMax Eco Classic 2700 Operating Instructions Manual

23795/09-14
AquaMax Eco Classic
1200/1900/2700/3600
Operating instructions Instrucciones de uso Notice d’emploi
-  -
2
A
AMX0001
B
AMX0002
C
AMX0003
D
AMX0004
23795-11-14_GA_AquaMax Eco Class2 2 19.11.2014 11:10:01
-  -
3
E
AMX0005
23795-11-14_GA_AquaMax Eco Class3 3 19.11.2014 11:10:01
-  -
4
F
AMX0006
23795-11-14_GA_AquaMax Eco Class4 4 19.11.2014 11:10:02
- English -
5
- English -
Information about these operating instructions
Welcome to OASE Living Water. You made a good choice with the purchase of this product AquaMax Eco Classic 1200/1900/2700/3600.
Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance with these instructions.
Adhere to the safety information for the correct and safe use of the unit. Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new
owner.
Symbols used in these instructions
The symbols used in this operating manual have the following meanings:
Risk of injury to persons due to dangerous electrical voltage
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.
Risk of personal injury caused by a general source of danger
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.
Important information for trouble-free operation.
A Reference to one or more figures. In this example: Reference to Fig. A.
Intended use
AquaMax Eco Classic 1200/1900/2700/3600, referred to in the following as "unit", may only be used as specified in the following:
For pumping normal pond water for filters, waterfalls and water courses.
Operation under observance of the technical data.
The following restrictions apply to the unit:
Do not use in swimming ponds.
Never use the unit to convey fluids other than water.
Never run the unit without water.
Do not use for commercial or industrial purposes.
Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
Do not connect to the domestic water supply.
Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pacemakers.
Use other than that intended
This unit can be dangerous and cause harm to persons if not used in accordance with these instructions. Any use not in accordance with these instructions or modification(s) to the unit will void the limited warranty.
WARNING
Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
23795-11-14_GA_AquaMax Eco Class5 5 19.11.2014 11:10:02
- English -
6
Installation and connection
A
Attention! Dangerous electrical voltage. Possible consequences: Death or serious injuries due to operation of this unit in a swimming pond. Protective measures:
Do NOT use this unit in a swimming pond.
Adhere to national and regional regulations.
Attention! Dangerous electrical voltage. Possible consequences: Death or severe injury. Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Installation
The unit can be placed submerged or dry. Always place the unit below water level. Place the unit horizontally on the ground ensuring its stable position.
Operating the unit in the pond
B The pump is in the pond. The return system, e.g. a pond filter, is connected to the pump outlet. How to proceed: C
1. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
2. Shorten the stepped hose adapter to the diameter of the hose used if necessary. – This reduces pressure losses. – Align the stepped hose adapter prior to tightening the union nut.
3. Connect the hose with the stepped hose adapter and secure with a hose clip.
Install the unit at a dry place
D Install the unit so that it is not exposed to direct sun radiation. How to proceed: E
1. Remove screws. – The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Screw the stepped hose adapter including sealing ring onto the inlet.
5. Shorten the stepped hose adapter to the diameter of the hose used if necessary. – This reduces pressure losses.
6. Connect the hose with the stepped hose adapter and secure with a hose clip. – Align the stepped hose adapter prior to tightening the union nut.
7. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
8. Shorten the stepped hose adapter to the diameter of the hose used if necessary. – This reduces pressure losses. – Align the stepped hose adapter prior to tightening the union nut.
9. Connect the hose with the stepped hose adapter and secure with a hose clip.
23795-11-14_GA_AquaMax Eco Class6 6 19.11.2014 11:10:02